Attended Versus Unattended Blood Pressure Measurement in a Real Life Setting
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
The debate on the generalizability of the SPRINT (Systolic Blood Pressure Intervention Trial) findings raised considerable interest in the technique of unattended office blood pressure (BP) measurement. It remains elusive, however, whether unattended BP measurement yields lower values than conventional measurements in a real world setting with subjects consulting their personal general practitioner in a familiar office. We performed a cross-sectional study in 158 patients in 4 general practitioners’ offices and compared conventional auscultatory office BP to unattended automated office BP in 107 subjects (group 1) and unattended to attended automated office BP in another 51 subjects (group 2). Unattended BP was calculated as the mean of 3 automated measurements performed in a separate room after 5 minutes of rest. Additionally, patients documented home BP for 7 days after the consultation. Mean auscultatory office, unattended office and home BP were 144.6/81.0, 144.1/79.9, and 135.5/78.3 mm Hg in group 1; unattended and attended automated office BP were 134.2/80.6 and 135.7/80.6 mm Hg in group 2. Systolic attended and unattended office BP values were significantly higher than home BP ( P <0.001, P <0.01, respectively). Attended and unattended office BP, however, did neither show a significant difference in group 1 nor in group 2 ( P >0.05 each). Bland–Altman analysis revealed a bias of 0.5 mm Hg systolic and 1.1 mm Hg diastolic in group 1 and −1.5 mm Hg systolic and 0 mm Hg diastolic in group 2. In conclusion, the present findings show that unattended and attended office BP measurements achieve comparable results, if measurements take place at a familiar general practitioner’s office.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Randomized Trial of Intensive versus Standard Blood-Pressure Control
The SPRINT Research Group (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1511939 · Cited by 6,325
Hansson, L., Zanchetti, A., Carruthers, S. G., Dahlöf, B., Elmfeldt, D., Julius, S., Ménard, J., Rahn, K. H., Wedel, H., & Westerling, S. (1998) · The Lancet · doi:10.1016/s0140-6736(98)04311-6 · Cited by 5,728
Effects of intensive blood-pressure control in type 2 diabetes mellitus
(2010) · New England Journal of Medicine · doi:10.1056/nejmoa1001286 · Cited by 3,598
Hemodynamic Patterns of Age-Related Changes in Blood Pressure: The Framingham Heart Study
Franklin, S. S., Gustin, W., Wong, N. D., Larson, M. G., Weber, M. A., Kannel, W. B., & Levy, D. (1997) · Circulation · doi:10.1161/01.cir.96.1.308 · Cited by 2,321
Guideline for the diagnosis and management of hypertension in adults - 2016
Gabb, G. M., Mangoni, A. A., Anderson, C. S., Cowley, D., Dowden, J. S., Golledge, J., Hankey, G. J., Howes, F. S., Leckie, L., Perkovic, V., et al. (2016) · Medical Journal of Australia · doi:10.5694/mja16.00526 · Cited by 406
Measurement of Blood Pressure in the Office: Recognizing the Problem and Proposing the Solution
Myers, M. G., Godwin, M., Dawes, M., Kiss, A., Tobe, S. W., & Kaczorowski, J. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.141879 · Cited by 260
Drawz, P. E., Pajewski, N. M., Bates, J. T., Bello, N. A., Cushman, W. C., Dwyer, J. P., Fine, L. J., Goff, D. C., Haley, W. E., Krousel-Wood, M., et al. (2017) · Hypertension · doi:10.1161/hypertensionaha.116.08076 · Cited by 170
Masked hypertension is “unmasked” by low-intensity exercise blood pressure
Schultz, M. G., Hare, J. L., Marwick, T. H., Stowasser, M., & Sharman, J. E. (2011) · Blood Pressure · doi:10.3109/08037051.2011.566251 · Cited by 104
Cited by
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
Cheung, A. K., Chang, T. I., Cushman, W. C., Furth, S. L., Hou, F. F., Ix, J. H., Knoll, G. A., Muntner, P., Pecoits-Filho, R., Sarnak, M. J., et al. (2021) · Kidney International · doi:10.1016/j.kint.2020.11.003 · Cited by 1,452
Writing Committee Members*, Jones, D. W., Ferdinand, K. C., Taler, S. J., Johnson, H. M., Shimbo, D., Abdalla, M., Altieri, M. M., Bansal, N., Bello, N. A., et al. (2025) · Hypertension · doi:10.1161/hyp.0000000000000249 · Cited by 310
Jones, D. W., Ferdinand, K. C., Taler, S. J., Johnson, H. M., Shimbo, D., Abdalla, M., Altieri, M. M., Bansal, N., Bello, N. A., Bress, A. P., et al. (2025) · JACC · doi:10.1016/j.jacc.2025.05.007 · Cited by 280
Roerecke, M., Kaczorowski, J., & Myers, M. G. (2019) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2018.6551 · Cited by 216
Metadata
- Authors
- Bauer, F., Seibert, F. S., Rohn, B., Bauer, K. A. R., Rolshoven, E., Babel, N., & Westhoff, T. H.
- Venue
- Hypertension
- Published
- 2018-02
- Volume
- 71
- Issue
- 2
- Pages
- 243-249
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2781323066
- Cited by
- 91
- References
- 8
- FWCI
- 10.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Attended Versus Unattended Blood Pressure Measurement in a Real Life Setting. https://app.cochat.ai/papers/10.1161/hypertensionaha.117.10026
- The paper
- Bauer, F., Seibert, F. S., Rohn, B., Bauer, K. A. R., Rolshoven, E., Babel, N., & Westhoff, T. H. (2018). Attended Versus Unattended Blood Pressure Measurement in a Real Life Setting. Hypertension. https://doi.org/10.1161/hypertensionaha.117.10026
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.