CoChat

Prognostic Value of Masked Uncontrolled Hypertension: Systematic Review and Meta-Analysis

Open access
Pierdomenico, Sante D., Pierdomenico, Anna M., Coccina, Francesca, Clement, Denis L., De Buyzere, Marc L., De Bacquer, Dirk A., Ben-Dov, Iddo Z., Vongpatanasin, Wanpen, Banegas, José R., Ruilope, Luis M., Thijs, Lutgarde, Staessen, Jan A. · 2018 · Hypertension
Cited by 118

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

The prognostic relevance of masked uncontrolled hypertension (MUCH) is incompletely clear, and its global impact on cardiovascular outcomes and mortality has not been assessed. The aim of this study was to perform a meta-analysis on the prognostic value of MUCH. We searched for articles assessing outcome in patients with MUCH compared with those with controlled hypertension (CH) and reporting adjusted hazard ratio and 95% CI. We identified 6 studies using ambulatory blood pressure monitoring (12 610 patients with 933 events) and 5 using home blood pressure measurement (17 742 patients with 394 events). The global population included 30 352 patients who experienced 1327 events. Selected studies had cardiovascular outcomes and all-cause mortality as primary outcome, and the main result is a composite of these events. The overall adjusted hazard ratio was 1.80 (95% CI, 1.57–2.06) for MUCH versus CH. Subgroup meta-analysis showed that adjusted hazard ratio was 1.83 (95% CI, 1.52–2.21) in studies using ambulatory blood pressure monitoring and 1.75 (95% CI, 1.38–2.20) in those using home blood pressure measurement. Risk was significantly higher in MUCH than in CH independently of follow-up length and types of studied events. MUCH was at significantly higher risk than CH in all ethnic groups, but the highest hazard ratio was found in studies, including black patients. Risk of cardiovascular events and all-cause mortality is significantly higher in patients with MUCH than in those with CH. MUCH detected by ambulatory or home blood pressure measurement seems to convey similar prognostic information.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hypertensionaha.118.11499

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

1 retracted

Show all 11 references

Cited by

See all 118

Metadata

Authors
Pierdomenico, S. D., Pierdomenico, A. M., Coccina, F., Clement, D. L., De Buyzere, M. L., De Bacquer, D. A., Ben-Dov, I. Z., Vongpatanasin, W., Banegas, J. R., Ruilope, L. M., Thijs, L., & Staessen, J. A.
Venue
Hypertension
Published
2018-10
Volume
72
Issue
4
Pages
862-869
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2891626867
Cited by
118
References
11
FWCI
11.35
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prognostic Value of Masked Uncontrolled Hypertension: Systematic Review and Meta-Analysis. https://app.cochat.ai/papers/10.1161/hypertensionaha.118.11499
The paper
Pierdomenico, S. D., Pierdomenico, A. M., Coccina, F., Clement, D. L., De Buyzere, M. L., De Bacquer, D. A., Ben-Dov, I. Z., Vongpatanasin, W., Banegas, J. R., Ruilope, L. M., Thijs, L., & Staessen, J. A. (2018). Prognostic Value of Masked Uncontrolled Hypertension: Systematic Review and Meta-Analysis. Hypertension. https://doi.org/10.1161/hypertensionaha.118.11499

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.