Incidence of Defibrillator Shocks After Elective Generator Exchange Following Uneventful First Battery Life
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: A significant number of implantable cardioverter‐defibrillator ( ICD ) patients do not experience shocks after ICD implant. Elective generator exchange ( GE ) has been associated with increased risk of infection and ICD lead failure. There is a paucity of contemporary data reporting on shock incidence with replacement devices. Methods and Results: Patients undergoing elective GE (n=24 203) who transmit data remotely via a remote monitoring system were analyzed to determine the incidence of ICD shocks after GE . A total of 16 230 patients (67%) did not experience a shock with the first ICD (group A), and 7973 (33%) received at least 1 shock (group B). Patients in group A were older (71.3 versus 68.8 years, P <0.001) and more often female (71% versus 77% male, P <0.001). Over an average follow‐up of 1.9±1.2 years after GE , the proportion of patients with shocks and risk of ICD shocks was lower for those who did not receive a shock during the first battery life (group A: 9.9% versus 27.7%, hazard ratio 0.36, 95% CI 0.34 to 0.38, P <0.001). The cumulative rate of ICD shocks at 5 years after GE was 25.7% in group A and 51.1% in group B. Conclusions: In this large cohort of ICD patients implanted across the United States, two thirds did not receive ICD shock therapy prior to GE . The occurrence of ICD shocks prior to GE is an important predictor of shocks after GE ; however, even among those without shocks during first battery life, the incidence of shocks at 5 years following GE is >25%. These data should support informed decision making for patients and physicians at the time of ICD generator end of service.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Saxon, L. A., Hayes, D. L., Gilliam, F. R., Heidenreich, P. A., Day, J., Seth, M., Meyer, T. E., Jones, P. W., & Boehmer, J. P. (2010) · Circulation · doi:10.1161/circulationaha.110.960633 · Cited by 515 · cited 1×
“without cardiac resynchronization devices, previous data from the ALTITUDE database have demonstrated that the incidence of shocks, both appropriate and inappropriate, is similar between ICD and CRT-D recipients in the first 5 years after device implant.(16) Our data corroborate these findings and”
ResultSelf-citation
Cited by
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab670 · Cited by 19,442
2021 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab368 · Cited by 13,344
2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure
Ponikowski, P., Voors, A. A., Anker, S. D., Bueno, H., Cleland, J. G. F., Coats, A. J. S., Falk, V., González-Juanatey, J. R., Harjola, V.-P., Jankowska, E. A., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw128 · Cited by 11,429
2016 ESC Guidelines for the Diagnosis and Treatment of Acute and Chronic Heart Failure
Ponikowski, P., Voors, A. A., Anker, S. D., Bueno, H., Cleland, J. G. F., Coats, A. J. S., Falk, V., González-Juanatey, J. R., Harjola, V.-P., Jankowska, E. A., et al. (2016) · European Journal of Heart Failure · doi:10.1002/ejhf.592 · Cited by 5,866
Authors/Task Force Members:, McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., et al. (2022) · European Journal of Heart Failure · doi:10.1002/ejhf.2333 · Cited by 2,171
Metadata
- Authors
- Merchant, F. M., Jones, P., Wehrenberg, S., Lloyd, M. S., & Saxon, L. A.
- Venue
- Journal of the American Heart Association
- Published
- 2014-12-17
- Volume
- 3
- Issue
- 6
- Pages
- e001289-e001289
- ISSN
- 2047-9980 (ISSN-L)
- OpenAlex
- W2105665289
- Cited by
- 59
- References
- 2
- FWCI
- 3.37
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.