CoChat

Patterns of Anticoagulation Use and Cardioembolic Risk After Catheter Ablation for Atrial Fibrillation

Open access
Noseworthy, Peter A., Yao, Xiaoxi, Deshmukh, Abhishek J., Van Houten, Holly, Sangaralingham, Lindsey R., Siontis, Konstantinos C., Piccini, Jonathan P., Asirvatham, Samuel J., Friedman, Paul A., Packer, Douglas L., Gersh, Bernard J., Shah, Nilay D. · 2015 · Journal of the American Heart Association
Cited by 87

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Background: There is significant practice variation in oral anticoagulation ( OAC ) use following catheter ablation for atrial fibrillation. It is not clear whether the risk of cardioembolism increases after discontinuation of OAC following catheter ablation. Methods and Results: We identified 6886 patients within a large national administrative claims database who underwent catheter ablation for atrial fibrillation between January 1, 2005, and September 30, 2014. We assessed the effect of time off of OAC by CHA 2 DS 2 ‐ VAS c score (after adjusting for other comorbidities) on risk of cardioembolism, using Cox proportional hazards models. There was an increase in the use of non–vitamin K OAC after ablation from 0% in 2005 to 69.8% in 2014. OAC discontinuation was high, with only 60.5% and 31.3% of patients remaining on OAC at 3 and 12 months, respectively. The rate of discontinuation was higher in low‐risk patients (82% versus 62.5% at 12 months for CHA 2 DS 2 ‐ VAS c 0–1 versus ≥2, respectively; P <0.001). Stroke occurred in 1.4% of patients with CHA 2 DS 2 ‐ VAS c ≥2 and 0.3% of those with CHA 2 DS 2 ‐ VAS c 0 or 1 over the study follow‐up. The risk of cardioembolism in the first 3 months after ablation was increased among those with any time off OAC (hazard ratio 8.06 [95% CI 1.53–42.3], P <0.05). The risk of cardioembolism beyond 3 months was increased with OAC discontinuation among high‐risk patients (hazard ratio 2.48 [95% CI 1.11–5.52], P <0.05) but not low‐risk patients. Conclusion: The overall risk of stroke in postablation patients is low; however, OAC discontinuation after ablation is common and is associated with increased risk of cardioembolism for all patients within the first 3 months and for high‐risk patients in the long term. Continuing OAC for at least 3 months in all patients and indefinitely in high‐risk patients appears to be the safest strategy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/jaha.115.002597

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 87

Metadata

Authors
Noseworthy, P. A., Yao, X., Deshmukh, A. J., Van Houten, H., Sangaralingham, L. R., Siontis, K. C., Piccini, J. P., Asirvatham, S. J., Friedman, P. A., Packer, D. L., Gersh, B. J., & Shah, N. D.
Venue
Journal of the American Heart Association
Published
2015-10-29
Volume
4
Issue
11
ISSN
2047-9980 (ISSN-L)
OpenAlex
W2131656089
Cited by
87
References
11
FWCI
5.35
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Patterns of Anticoagulation Use and Cardioembolic Risk After Catheter Ablation for Atrial Fibrillation. https://app.cochat.ai/papers/10.1161/jaha.115.002597
The paper
Noseworthy, P. A., Yao, X., Deshmukh, A. J., Van Houten, H., Sangaralingham, L. R., Siontis, K. C., Piccini, J. P., Asirvatham, S. J., Friedman, P. A., Packer, D. L., Gersh, B. J., & Shah, N. D. (2015). Patterns of Anticoagulation Use and Cardioembolic Risk After Catheter Ablation for Atrial Fibrillation. Journal of the American Heart Association. https://doi.org/10.1161/jaha.115.002597

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.