Stent Placement in Acute Cerebral Artery Occlusion: Use of a Self-Expandable Intracranial Stent for Acute Stroke Treatment
Open accessAbstract
Background and Purpose— Stent placement has been applied in small case series as a rescue therapy in combination with different thrombolytic agents, percutaneous balloon angioplasty (PTA), and mechanical thromboembolectomy (MT) in acute stroke treatment. These studies report a considerable mortality and a high rate of intracranial hemorrhages when balloon-mounted stents were used. This study was performed to evaluate feasibility, efficacy, and safety of intracranial artery recanalization for acute ischemic stroke using a self-expandable stent. Methods— All patients treated with an intracranial stent for acute cerebral artery occlusion were included. Treatment comprised intraarterial thrombolysis, thromboaspiration, MT, PTA, and stent placement. Recanalization result was assessed by follow-up angiography immediately after stent placement. Complications related to the procedure and outcome at 3 months were assessed. Results— Twelve patients (median NIHSS 14, mean age 63 years) were treated with intracranial stents for acute ischemic stroke. Occlusions were located in the posterior vertebrobasilar circulation (n=6) and in the anterior circulation (n=6). Stent placement was feasible in all procedures and resulted in partial or complete recanalization (TIMI 2/3) in 92%. No vessel perforations, subarachnoid, or symptomatic intracerebral hemorrhages occurred. One dissection was found after thromboaspiration and PTA. Three patients (25%) had a good outcome (mRS 0 to 2), 3 (25%) a moderate outcome (mRS 3), and 6 (50%) a poor outcome (mRS 4 to 6). Mortality was 33.3%. Conclusions— Intracranial placement of a self-expandable stent for acute ischemic stroke is feasible and seems to be safe to achieve sufficient recanalization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue Plasminogen Activator for Acute Ischemic Stroke
(1995) · New England Journal of Medicine · doi:10.1056/nejm199512143332401 · Cited by 11,654
Interobserver agreement for the assessment of handicap in stroke patients
van Swieten, J. C., Koudstaal, P. J., Visser, M. C., Schouten, H. J., & van Gijn, J. (1988) · Stroke · doi:10.1161/01.str.19.5.604 · Cited by 6,512
Cited by
A Randomized Trial of Intraarterial Treatment for Acute Ischemic Stroke
Berkhemer, O. A., Fransen, P. S. S., Beumer, D., van den Berg, L. A., Lingsma, H. F., Yoo, A. J., Schonewille, W. J., Vos, J. A., Nederkoorn, P. J., Wermer, M. J. H., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1411587 · Cited by 6,657
Ischemic stroke in the elderly: an overview of evidence
Chen, R.-L., Balami, J. S., Esiri, M. M., Chen, L.-K., & Buchan, A. M. (2010) · Nature Reviews Neurology · doi:10.1038/nrneurol.2010.36 · Cited by 291
Levy, E. I., Siddiqui, A. H., Crumlish, A., Snyder, K. V., Hauck, E. F., Fiorella, D. J., Hopkins, L. N., & Mocco, J. (2009) · Stroke · doi:10.1161/strokeaha.109.561274 · Cited by 265
Mechanical thrombectomy for the treatment of acute ischemic stroke
Fields, J. D., Lindsay, K., Liu, K. C., Nesbit, G. M., & Lutsep, H. L. (2010) · Expert Review of Cardiovascular Therapy · doi:10.1586/erc.10.8 · Cited by 16
Metadata
- Authors
- Brekenfeld, C., Schroth, G., Mattle, H. P., Do, D.-D., Remonda, L., Mordasini, P., Arnold, M., Nedeltchev, K., Meier, N., & Gralla, J.
- Venue
- Stroke
- Published
- 2009-03
- Volume
- 40
- Issue
- 3
- Pages
- 847-852
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2159931276
- Cited by
- 172
- References
- 2
- FWCI
- 18.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stent Placement in Acute Cerebral Artery Occlusion: Use of a Self-Expandable Intracranial Stent for Acute Stroke Treatment. https://app.cochat.ai/papers/10.1161/strokeaha.108.533810
- The paper
- Brekenfeld, C., Schroth, G., Mattle, H. P., Do, D.-D., Remonda, L., Mordasini, P., Arnold, M., Nedeltchev, K., Meier, N., & Gralla, J. (2009). Stent Placement in Acute Cerebral Artery Occlusion: Use of a Self-Expandable Intracranial Stent for Acute Stroke Treatment. Stroke. https://doi.org/10.1161/strokeaha.108.533810
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.