The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
New Generation of Flow Diverter (Surpass) for Unruptured Intracranial Aneurysms: A Prospective Single-Center Study in 37 Patients
Abstract
Background and Purpose—: In patients harboring intracranial aneurysms, the major goal in treatment is to prevent bleeding. A new generation of an endoluminal device (Surpass Flow Diverter [Surpass]) was developed to reconstruct parent artery and occlude the aneurysm. We present our clinical and angiographic single-center experience. Methods—: Patients with a wide range of complex unruptured aneurysms were treated with the Surpass placed in the parent artery and bridging the aneurysm. Clinical and angiographic follow-up were performed at 6 months. Data were prospectively collected. Results—: Thirty seven patients (mean age, 56 years; range, 32–79), harboring 49 unruptured aneurysms were treated at our center. All except 1 patient were treated with a single device. Successful delivery of the device was achieved in all patients. All 35 nonbifurcation aneurysm necks were covered completely, whereas 14 bifurcation aneurysms were only partially covered. There was no major periprocedural morbidity or mortality. During follow-up, 4 patients (10.4%) experienced transient neurological deficit. One patient (3%) developed a minor stroke at 4-month follow-up with persistent neurological deficit. Twelve patients had neurological symptoms related to their aneurysm and 7 showed improvement of these symptoms during follow-up. At 6-month follow-up, 29 of 31 aneurysms studied that had complete neck coverage showed a complete occlusion (94%) including 1 case with a 95% to 100% occlusion, whereas 5 of the 10 bifurcation aneurysms were occluded. Conclusions—: Our study shows high safety and efficacy profile of a new generation endoluminal device in treatment of complex intracranial aneurysms. Long-term studies of treated bifurcation aneurysms are needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of clopidogrel added to aspirin in patients with recent lacunar stroke
The SPS3 Investigators (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1204133 · Cited by 679
Ferns, S. P., Sprengers, M. E. S., van Rooij, W. J., Rinkel, G. J. E., van Rijn, J. C., Bipat, S., Sluzewski, M., & Majoie, C. B. L. M. (2009) · Stroke · doi:10.1161/strokeaha.109.553099 · Cited by 455
Cited by
Endovascular Treatment of Intracranial Aneurysms: Current Status
Pierot, L., & Wakhloo, A. K. (2013) · Stroke · doi:10.1161/strokeaha.113.000733 · Cited by 289
Self-citation
Metadata
- Authors
- De Vries, J., Boogaarts, J., Van Norden, A., & Wakhloo, A. K.
- Venue
- Stroke
- Published
- 2013-06
- Volume
- 44
- Issue
- 6
- Pages
- 1567-1577
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2117445677
- Cited by
- 165
- References
- 2
- FWCI
- 11.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: New Generation of Flow Diverter (Surpass) for Unruptured Intracranial Aneurysms: A Prospective Single-Center Study in 37 Patients. https://app.cochat.ai/papers/10.1161/strokeaha.111.000434
- The paper
- De Vries, J., Boogaarts, J., Van Norden, A., & Wakhloo, A. K. (2013). New Generation of Flow Diverter (Surpass) for Unruptured Intracranial Aneurysms: A Prospective Single-Center Study in 37 Patients. Stroke. https://doi.org/10.1161/strokeaha.111.000434
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.