The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Stent-Assisted Coiling of Intracranial Aneurysms: Predictors of Complications, Recanalization, and Outcome in 508 Cases
Abstract
Background and Purpose—: Self-expanding stents are increasingly used for treatment of complex intracranial aneurysms. We assess the safety and the efficacy of intracranial stenting and determine predictors of treatment outcomes. Methods—: A total of 508 patients with 552 aneurysms were treated with Neuroform and Enterprise stents between 2006 and 2011 at our institution. A multivariate analysis was conducted to identify predictors of complications, recanalization, and outcome. Results—: Of 508 patients, 461 (91%) were treated electively and 47 (9%) in the setting of subarachnoid hemorrhage. Complications occurred in 6.8% of patients. In multivariate analysis, subarachnoid hemorrhage, delivery of coils before stent placement, and carotid terminus/middle cerebral artery aneurysm locations were independent predictors of procedural complications. Angiographic follow-up was available for 87% of patients at a mean of 26 months. The rates of recanalization and retreatment were, respectively, 12% and 6.4%. Older age, previously coiled aneurysms, larger aneurysms, incompletely occluded aneurysms, Neuroform stent, and aneurysm location were predictors of recanalization. Favorable outcomes were seen in 99% of elective patients and 51% of subarachnoid hemorrhage patients. Patient age, ruptured aneurysms, and procedural complications were predictors of outcome. Conclusions—: Stent-assisted coiling of intracranial aneurysms is safe, effective, and provides durable aneurysm closure. Higher complication rates and worse outcomes are associated with treatment of ruptured aneurysms. Stent delivery before coil deployment reduces the risk of procedural complications. Staging the procedure may not improve procedural safety. Closed-cell stents are associated with significantly lower recanalization rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Practical Statistics for Medical Research
Altman, D. G. (1990) · doi:10.1201/9780429258589 · Cited by 10,668
Raymond, J., Guilbert, F., Weill, A., Georganos, S. A., Juravsky, L., Lambert, A., Lamoureux, J., Chagnon, M., & Roy, D. (2003) · Stroke · doi:10.1161/01.str.0000073841.88563.e9 · Cited by 1,496
PRACTICAL STATISTICS FOR MEDICAL RESEARCH
Ludbrook, J. (1991) · Australian and New Zealand Journal of Surgery · doi:10.1111/j.1445-2197.1991.tb00019.x · Cited by 1,213
Piotin, M., Blanc, R., Spelle, L., Mounayer, C., Piantino, R., Schmidt, P. J., & Moret, J. (2010) · Stroke · doi:10.1161/strokeaha.109.558114 · Cited by 644
Saatci, I., Yavuz, K., Ozer, C., Geyik, S., & Cekirge, H. S. (2012) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3246 · Cited by 368
Benitez, R. P., Silva, M. T., Klem, J., Veznedaroglu, E., & Rosenwasser, R. H. (2004) · Neurosurgery · doi:10.1227/01.neu.0000124484.87635.cd · Cited by 364
Self-citationChalouhi, N., Jabbour, P. M., Gonzalez, L. F., Dumont, A. S., Rosenwasser, R. H., Starke, R. M., Gordon, D., Hann, S. W., & Tjoumakaris, S. I. (2012) · Neurosurgery · doi:10.1227/neu.0b013e318265a416 · Cited by 146
Self-citationStent-Associated Flow Remodeling Causes Further Occlusion of Incompletely Coiled Aneurysms
Lawson, M. F., Newman, W. C., Chi, Y., Mocco, J., & Hoh, B. L. (2011) · Neurosurgery · doi:10.1227/neu.0b013e3182181c2b · Cited by 130
Closed-Cell Stent for Coil Embolization of Intracranial Aneurysms: Clinical and Angiographic Results
Wakhloo, A. K., Linfante, I., Silva, C. F., Samaniego, E. A., Dabus, G. C., Etezadi, V., Spilberg, G., & Gounis, M. J. (2012) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3034 · Cited by 43
Current Status of Pipeline Embolization Device in the Treatment of Intracranial Aneurysms: A Review
Tse, M. M. Y., Yan, B., Dowling, R., & Mitchell, P. J. (2012) · World Neurosurgery · doi:10.1016/j.wneu.2012.09.023 · Cited by 40
Metadata
- Authors
- Chalouhi, N., Jabbour, P., Singhal, S., Drueding, R., Starke, R. M., Dalyai, R. T., Tjoumakaris, S., Gonzalez, L. F., Dumont, A. S., Rosenwasser, R., & Randazzo, C. G.
- Venue
- Stroke
- Published
- 2013-05
- Volume
- 44
- Issue
- 5
- Pages
- 1348-1353
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2111268578
- Cited by
- 401
- References
- 10
- FWCI
- 22.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.