CoChat

Annexin V–CLIO: A Nanoparticle for Detecting Apoptosis by MRI

Open access
Schellenberger, Eyk A., Bogdanov, Alexei, Högemann, Dagmar, Tait, Jonathan, Weissleder, Ralph, Josephson, Lee · 2002 · Molecular Imaging
Cited by 149

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Annexin V, which recognizes the phosphatidylserine of apoptotic cells, was conjugated to crosslinked iron oxide (CLIO) nanoparticles, a functionalized superparamagnetic preparation developed for target-specific magnetic resonance imaging (MRI). The resulting nanoparticle had an average of 2.7 annexin V proteins linked per CLIO nanoparticle through disulfide bonds. Using camptothecin to induce apoptosis, a mixture of Jurkat T cells (69% healthy and 31% apoptotic) was incubated with annexin V–CLIO and was applied to magnetic columns. The result was an almost complete removal of the apoptotic cells (>99%). In a phantom MRI experiment, untreated control cells (12% apoptotic cells, 88% healthy cells) and camptothecin-treated cells (65% apoptotic cells, 35% healthy cells) were incubated with either annexin V–CLIO (1.0, 0.5, and 0.1 μg Fe/mL) or with unlabeled CLIO. A significant signal decrease of camptothecin-treated cells relative to untreated cells was observed even at the lowest concentration tested. Unmodified CLIO failed to cause a significant signal change of apoptotic cells. Hence, annexin V–CLIO allowed the identification of cell suspensions containing apoptotic cells by MRI even at very low concentrations of magnetic substrate. Conjugation of annexin V to CLIO affords a strategy for the development of a MRI imaging probe for detecting apoptosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1162/15353500200202103

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 149

Metadata

Authors
Schellenberger, E. A., Bogdanov, A., Högemann, D., Tait, J., Weissleder, R., & Josephson, L.
Venue
Molecular Imaging
Published
2002-04-01
Volume
1
Issue
2
Pages
102-7
ISSN
  • 1535-3508 (ISSN-L)
  • 1536-0121
OpenAlex
W2110936394
Cited by
149
References
4
FWCI
8.05
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Annexin V–CLIO: A Nanoparticle for Detecting Apoptosis by MRI. https://app.cochat.ai/papers/10.1162/15353500200202103
The paper
Schellenberger, E. A., Bogdanov, A., Högemann, D., Tait, J., Weissleder, R., & Josephson, L. (2002). Annexin V–CLIO: A Nanoparticle for Detecting Apoptosis by MRI. Molecular Imaging. https://doi.org/10.1162/15353500200202103

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.