Organic Alternatives to Quantum Dots for Intraoperative Near-Infrared Fluorescent Sentinel Lymph Node Mapping
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Intraoperative near-infrared (NIR) fluorescence imaging provides the surgeon with real-time image guidance during cancer and other surgeries. We have previously reported the use of NIR fluorescent quantum dots (QDs) for sentinel lymph node (SLN) mapping. However, because of concerns over potential toxicity, organic alternatives to QDs will be required for initial clinical studies. We describe a family of 800 nm organic heptamethine indocyanine-based contrast agents for SLN mapping spanning a spectrum from 775 Da small molecules to 7 MDa nanocolloids. We provide a detailed characterization of the optical and physical properties of these contrast agents and discuss the advantages and disadvantages of each. We present robust methods for the covalent conjugation, purification, and characterization of proteins with tetra-sulfonated heptamethine indocyanines, including mass spectroscopic site mapping of highly substituted molecules. One contrast agent, NIR fluorescent human serum albumin (HSA800), emerged as the molecule with the best overall performance with respect to entry to lymphatics, flow to the SLN, retention in the SLN, fluorescence yield and reproducibility. This preclinical study, performed on large animals approaching the size of humans, should serve as a foundation for future clinical studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Technical Details of Intraoperative Lymphatic Mapping for Early Stage Melanoma
Morton, D. L. (1992) · Archives of Surgery · doi:10.1001/archsurg.1992.01420040034005 · Cited by 4,371 · cited 1×
“Introduction The sentinel lymph node (SLN) hypothesis, advanced by Morton and colleagues in the early 1990s [1], states that sampling of the first lymph node to receive lymphatic drainage from a solid tumor is sufficient to assess for the presence or absence of lymphatic metastasis.”
BackgroundIn vivo near-infrared fluorescence imaging
Frangioni, J. V. (2003) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2003.08.007 · Cited by 2,653
Self-citationNear-infrared fluorescent type II quantum dots for sentinel lymph node mapping
Kim, S., Lim, Y. T., Soltesz, E. G., De Grand, A. M., Lee, J., Nakayama, A., Parker, J. A., Mihaljevic, T., Laurence, R. G., Dor, D. M., et al. (2004) · Nature Biotechnology · doi:10.1038/nbt920 · Cited by 2,087 · cited 4×
“In this regard, NIR QDs remain the most robust of all SLN tracers, having remarkable photostability [11] and high fluorescence yield.”
BackgroundMethodSelf-citationNtziachristos, V., Bremer, C., & Weissleder, R. (2003) · European Radiology · doi:10.1007/s00330-002-1524-x · Cited by 982 · cited 1×
“[6,7]), which theoretically could detect lymph nodes 4–10 cm below the surface.”
BackgroundFluorescence-enhanced, near infrared diagnostic imaging with contrast agents
Sevick-Muraca, E. M., Houston, J. P., & Gurfinkel, M. (2002) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(02)00356-3 · Cited by 328 · cited 1×
“[6,7]), which theoretically could detect lymph nodes 4–10 cm below the surface.”
BackgroundRadioguided sentinel lymph node biopsy in breast cancer surgery.
Mariani, G., Moresco, L., Viale, G., Villa, G., Bagnasco, M., Canavese, G., Buscombe, J. R., Strausś, H. W., & Paganelli, G. (2001) · PubMed · Cited by 327
Self-citationIntraoperative Sentinel Lymph Node Mapping of the Lung Using Near-Infrared Fluorescent Quantum Dots
Soltesz, E. G., Kim, S., Laurence, R. G., DeGrand, A. M., Parungo, C. P., Dor, D. M., Cohn, L. H., Bawendi, M. G., Frangioni, J. V., & Mihaljevic, T. (2005) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2004.06.055 · Cited by 244 · cited 1×
“We have also demonstrated the use of inorganic/organic hybrid quantum dots (QDs) for NIR fluorescent SLN mapping in the skin [11], lung [12], esophagus [13], and pleural space [14] (reviewed in Ref.”
MethodSelf-citationImaging of Spontaneous Canine Mammary Tumors Using Fluorescent Contrast Agents
Reynolds, J. S., Troy, T. L., Mayer, R. H., Thompson, A. B., Waters, D. J., Cornell, K. K., Snyder, P. W., & Sevick-Muraca, E. M. (1999) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1999.tb01953.x · Cited by 204 · cited 1×
“in vivo SLN mapping [27], its small hydrodynamic diameter results in rapid transport out of the SLN, its QY is”
BackgroundAbsorption and fluorescence properties of cyanine dyes
Benson, R. C., & Kues, H. A. (1977) · Journal of Chemical & Engineering Data · doi:10.1021/je60075a020 · Cited by 202 · cited 1×
“(QY 13%; [20]) as calibration standard, under conditions of matched fluorophore absorbance.”
BackgroundAn Operational Near-Infrared Fluorescence Imaging System Prototype for Large Animal Surgery
De Grand, A. M., & Frangioni, J. V. (2003) · Technology in Cancer Research & Treatment · doi:10.1177/153303460300200607 · Cited by 189 · cited 2×
“The intraoperative NIR fluorescence imaging system optimized for large animal surgery [10] has been described in detail previously.”
BackgroundMethodSelf-citationSentinel Node Staging of Resectable Colon Cancer: Results of a Multicenter Study
Bertagnolli, M. M., Miedema, B. W., Redston, M. S., Dowell, J. M., Niedzwiecki, D., Fleshman, J. W., Bem, J., Mayer, R. J., Zinner, M. J., & Compton, C. C. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000140753.41357.20 · Cited by 161 · cited 1×
“In colon cancer, for example, studies for [31] and against [32] its use have been published.”
BackgroundSauda, K., Imasaka, T., & Ishibashi, N. (1986) · Analytical Chemistry · doi:10.1021/ac00126a016 · Cited by 125 · cited 3×
“to protein, and absolute affinity of the interaction is low [19,21,28,29], making it possible for dissociated ICG to”
BackgroundSentinel Lymph Node Mapping of the Pleural Space
Parungo, C. P., Colson, Y. L., Kim, S., Kim, S., Cohn, L. H., Bawendi, M. G., & Frangioni, J. V. (2005) · CHEST Journal · doi:10.1378/chest.127.5.1799 · Cited by 112 · cited 1×
“We have also demonstrated the use of inorganic/organic hybrid quantum dots (QDs) for NIR fluorescent SLN mapping in the skin [11], lung [12], esophagus [13], and pleural space [14] (reviewed in Ref.”
MethodSelf-citationNakayama, A., Bianco, A. C., Zhang, C., Lowell, B. B., & Frangioni, J. V. (2003) · Molecular Imaging · doi:10.1162/153535003765276273 · Cited by 109
Self-citationSentinel Lymph Node Mapping With Type-II Quantum Dots
Frangioni, J. V., Kim, S., Ohnishi, S., Kim, S., & Bawendi, M. G. (2007) · Humana Press eBooks · doi:10.1385/1-59745-369-2:147 · Cited by 85
Self-citationFunctional Near-Infrared Imaging for Cardiac Surgery and Targeted Gene Therapy
Nakayama, A., del Monte, F., Hajjar, R. J., & Frangioni, J. V. (2002) · Molecular Imaging · doi:10.1162/153535002321093972 · Cited by 77
Self-citationFunctional Near-Infrared Fluorescence Imaging for Cardiac Surgery and Targeted Gene Therapy
Nakayama, A., del Monte, F., Hajjar, R. J., & Frangioni, J. V. (2002) · Molecular Imaging · doi:10.1162/15353500200221333 · Cited by 75 · cited 1×
“Our laboratory has previously developed intraoperative NIR fluorescence imaging systems that permit anatomy (color video) and function (NIR fluorescence) to be acquired simultaneously and in real time [9,10].”
BackgroundSelf-citationLymph node localization of non-specific antibody-coated liposomes
Mangat, S., & Patel, H. M. (1985) · Life Sciences · doi:10.1016/0024-3205(85)90440-0 · Cited by 49 · cited 2×
“We also systemically addressed the factors known to affect lymphatic uptake and retention, such as hydrodynamic diameter, surface charge, and hydrophobicity [17,22,23].”
BackgroundMethodIRDye78 Conjugates for Near-Infrared Fluorescence Imaging
Zaheer, A., Wheat, T. E., & Frangioni, J. V. (2002) · Molecular Imaging · doi:10.1162/15353500200221302 · Cited by 48 · cited 1×
“These robust methods complement our previous work on the development of NIR fluorescent small molecules and peptides [33].”
MethodSelf-citationPan and Sentinel Lymph Node Visualization Using a Near-Infrared Fluorescent Probe
Josephson, L., Mahmood, U., Wunderbaldinger, P., Tang, Y., & Weissleder, R. (2003) · Molecular Imaging · doi:10.1162/15353500200302154 · Cited by 38
Dynamic tests to study liver function.
Burra, P., & Masier, A. (2004) · PubMed · Cited by 37
Homing of negatively charged albumins to the lymphatic system
Swart, P. J., Beljaars, L., Kuipers, M. E., Smit, C., Nieuwenhuis, P., & Meijer, D. K. F. (1999) · Biochemical Pharmacology · doi:10.1016/s0006-2952(99)00224-5 · Cited by 32 · cited 3×
“We also systemically addressed the factors known to affect lymphatic uptake and retention, such as hydrodynamic diameter, surface charge, and hydrophobicity [17,22,23].”
BackgroundMethodSentinel nodes of malignancies originating in the alimentary tract
Fujii, H., Kitagawa, Y., Kitajima, M., & Kubo, A. (2004) · Annals of Nuclear Medicine · doi:10.1007/bf02985608 · Cited by 31 · cited 1×
“Molecules with a hydrodynamic diameter less than approximately 10 nm have the potential to travel beyond the SLN, molecules with a 50–100 nm hydrodynamic diameter require up to 3 hr to label the SLN, and very large molecules (>200 nm) require up to 24 hr to label the SLN [16].”
BackgroundThe present role of indocyanine green angiography in ophthalmology
Regillo, C. D. (1999) · Current Opinion in Ophthalmology · doi:10.1097/00055735-199906000-00007 · Cited by 30
Cited by
Image-guided cancer surgery using near-infrared fluorescence
Vahrmeijer, A. L., Hutteman, M., van der Vorst, J. R., van de Velde, C. J. H., & Frangioni, J. V. (2013) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2013.123 · Cited by 1,466
Self-citationSchaafsma, B. E., Mieog, J. S. D., Hutteman, M., van der Vorst, J. R., Kuppen, P. J. K., Löwik, C. W. G. M., Frangioni, J. V., van de Velde, C. J. H., & Vahrmeijer, A. L. (2011) · Journal of Surgical Oncology · doi:10.1002/jso.21943 · Cited by 816
Self-citationNew Technologies for Human Cancer Imaging
Frangioni, J. V. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.14.3065 · Cited by 800
Self-citationTroyan, S. L., Kianzad, V., Gibbs-Strauss, S. L., Gioux, S., Matsui, A., Oketokoun, R., Ngo, L., Khamene, A., Azar, F., & Frangioni, J. V. (2009) · Annals of Surgical Oncology · doi:10.1245/s10434-009-0594-2 · Cited by 684
Self-citationMultimodal silica nanoparticles are effective cancer-targeted probes in a model of human melanoma
Benezra, M., Penate-Medina, O., Zanzonico, P. B., Schaer, D., Ow, H., Burns, A., DeStanchina, E., Longo, V., Herz, E., Iyer, S., et al. (2011) · Journal of Clinical Investigation · doi:10.1172/jci45600 · Cited by 645
Metadata
- Authors
- Ohnishi, S., Lomnes, S. J., Laurence, R. G., Gogbashian, A., Mariani, G., & Frangioni, J. V.
- Venue
- Molecular Imaging
- Publisher
- SAGE Publications
- Published
- 2005-07-01
- Volume
- 4
- Issue
- 3
- Pages
- 172-81
- ISSN
- 1535-3508 (ISSN-L)
- 1536-0121
- OpenAlex
- W2164624417
- Cited by
- 210
- References
- 24
- FWCI
- 6.67
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.