Organic Alternatives to Quantum Dots for Intraoperative Near-Infrared Fluorescent Sentinel Lymph Node Mapping
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Intraoperative near-infrared (NIR) fluorescence imaging provides the surgeon with real-time image guidance during cancer and other surgeries. We have previously reported the use of NIR fluorescent quantum dots (QDs) for sentinel lymph node (SLN) mapping. However, because of concerns over potential toxicity, organic alternatives to QDs will be required for initial clinical studies. We describe a family of 800 nm organic heptamethine indocyanine-based contrast agents for SLN mapping spanning a spectrum from 775 Da small molecules to 7 MDa nanocolloids. We provide a detailed characterization of the optical and physical properties of these contrast agents and discuss the advantages and disadvantages of each. We present robust methods for the covalent conjugation, purification, and characterization of proteins with tetra-sulfonated heptamethine indocyanines, including mass spectroscopic site mapping of highly substituted molecules. One contrast agent, NIR fluorescent human serum albumin (HSA800), emerged as the molecule with the best overall performance with respect to entry to lymphatics, flow to the SLN, retention in the SLN, fluorescence yield and reproducibility. This preclinical study, performed on large animals approaching the size of humans, should serve as a foundation for future clinical studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Technical Details of Intraoperative Lymphatic Mapping for Early Stage Melanoma
Morton, D. L. (1992) · Archives of Surgery · doi:10.1001/archsurg.1992.01420040034005 · Cited by 4,371 · cited 1×
“Introduction The sentinel lymph node (SLN) hypothesis, advanced by Morton and colleagues in the early 1990s [1], states that sampling of the first lymph node to receive lymphatic drainage from a solid tumor is sufficient to assess for the presence or absence of lymphatic metastasis.”
BackgroundIn vivo near-infrared fluorescence imaging
Frangioni, J. V. (2003) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2003.08.007 · Cited by 2,653
Self-citationNear-infrared fluorescent type II quantum dots for sentinel lymph node mapping
Kim, S., Lim, Y. T., Soltesz, E. G., De Grand, A. M., Lee, J., Nakayama, A., Parker, J. A., Mihaljevic, T., Laurence, R. G., Dor, D. M., et al. (2004) · Nature Biotechnology · doi:10.1038/nbt920 · Cited by 2,087 · cited 4×
“In this regard, NIR QDs remain the most robust of all SLN tracers, having remarkable photostability [11] and high fluorescence yield.”
BackgroundMethodSelf-citationNtziachristos, V., Bremer, C., & Weissleder, R. (2003) · European Radiology · doi:10.1007/s00330-002-1524-x · Cited by 982 · cited 1×
“[6,7]), which theoretically could detect lymph nodes 4–10 cm below the surface.”
BackgroundFluorescence-enhanced, near infrared diagnostic imaging with contrast agents
Sevick-Muraca, E. M., Houston, J. P., & Gurfinkel, M. (2002) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(02)00356-3 · Cited by 328 · cited 1×
“[6,7]), which theoretically could detect lymph nodes 4–10 cm below the surface.”
BackgroundRadioguided sentinel lymph node biopsy in breast cancer surgery.
Mariani, G., Moresco, L., Viale, G., Villa, G., Bagnasco, M., Canavese, G., Buscombe, J. R., Strausś, H. W., & Paganelli, G. (2001) · PubMed · Cited by 327
Self-citationIntraoperative Sentinel Lymph Node Mapping of the Lung Using Near-Infrared Fluorescent Quantum Dots
Soltesz, E. G., Kim, S., Laurence, R. G., DeGrand, A. M., Parungo, C. P., Dor, D. M., Cohn, L. H., Bawendi, M. G., Frangioni, J. V., & Mihaljevic, T. (2005) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2004.06.055 · Cited by 244 · cited 1×
“We have also demonstrated the use of inorganic/organic hybrid quantum dots (QDs) for NIR fluorescent SLN mapping in the skin [11], lung [12], esophagus [13], and pleural space [14] (reviewed in Ref.”
MethodSelf-citationImaging of Spontaneous Canine Mammary Tumors Using Fluorescent Contrast Agents
Reynolds, J. S., Troy, T. L., Mayer, R. H., Thompson, A. B., Waters, D. J., Cornell, K. K., Snyder, P. W., & Sevick-Muraca, E. M. (1999) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1999.tb01953.x · Cited by 204 · cited 1×
“in vivo SLN mapping [27], its small hydrodynamic diameter results in rapid transport out of the SLN, its QY is”
BackgroundAbsorption and fluorescence properties of cyanine dyes
Benson, R. C., & Kues, H. A. (1977) · Journal of Chemical & Engineering Data · doi:10.1021/je60075a020 · Cited by 202 · cited 1×
“(QY 13%; [20]) as calibration standard, under conditions of matched fluorophore absorbance.”
BackgroundAn Operational Near-Infrared Fluorescence Imaging System Prototype for Large Animal Surgery
De Grand, A. M., & Frangioni, J. V. (2003) · Technology in Cancer Research & Treatment · doi:10.1177/153303460300200607 · Cited by 189 · cited 2×
“The intraoperative NIR fluorescence imaging system optimized for large animal surgery [10] has been described in detail previously.”
BackgroundMethodSelf-citation
Cited by
Image-guided cancer surgery using near-infrared fluorescence
Vahrmeijer, A. L., Hutteman, M., van der Vorst, J. R., van de Velde, C. J. H., & Frangioni, J. V. (2013) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2013.123 · Cited by 1,466
Self-citationSchaafsma, B. E., Mieog, J. S. D., Hutteman, M., van der Vorst, J. R., Kuppen, P. J. K., Löwik, C. W. G. M., Frangioni, J. V., van de Velde, C. J. H., & Vahrmeijer, A. L. (2011) · Journal of Surgical Oncology · doi:10.1002/jso.21943 · Cited by 816
Self-citationNew Technologies for Human Cancer Imaging
Frangioni, J. V. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.14.3065 · Cited by 800
Self-citationTroyan, S. L., Kianzad, V., Gibbs-Strauss, S. L., Gioux, S., Matsui, A., Oketokoun, R., Ngo, L., Khamene, A., Azar, F., & Frangioni, J. V. (2009) · Annals of Surgical Oncology · doi:10.1245/s10434-009-0594-2 · Cited by 684
Self-citationMultimodal silica nanoparticles are effective cancer-targeted probes in a model of human melanoma
Benezra, M., Penate-Medina, O., Zanzonico, P. B., Schaer, D., Ow, H., Burns, A., DeStanchina, E., Longo, V., Herz, E., Iyer, S., et al. (2011) · Journal of Clinical Investigation · doi:10.1172/jci45600 · Cited by 645
Fluorescence Enhancement by Au Nanostructures: Nanoshells and Nanorods
Bardhan, R., Grady, N. K., Cole, J. R., Joshi, A., & Halas, N. J. (2009) · ACS Nano · doi:10.1021/nn900001q · Cited by 617
Image-Guided Surgery Using Invisible Near-Infrared Light: Fundamentals of Clinical Translation
Gioux, S., Choi, H. S., & Frangioni, J. V. (2010) · Molecular Imaging · doi:10.2310/7290.2010.00034 · Cited by 599
Self-citationBiju, V., Itoh, T., Anas, A., Sujith, A., & Ishikawa, M. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2185-7 · Cited by 574
Fluorescent Silica Nanoparticles with Efficient Urinary Excretion for Nanomedicine
Burns, A. A., Vider, J., Ow, H., Herz, E., Penate-Medina, O., Baumgart, M., Larson, S. M., Wiesner, U., & Bradbury, M. (2009) · Nano Letters · doi:10.1021/nl803405h · Cited by 474
Synthesis and In Vivo Fate of Zwitterionic Near‐Infrared Fluorophores
Choi, H. S., Nasr, K., Alyabyev, S., Feith, D., Lee, J. H., Kim, S. H., Ashitate, Y., Hyun, H., Patonay, G., Strekowski, L., et al. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201102459 · Cited by 378
Self-citationNanoparticles for Biomedical Imaging: Fundamentals of Clinical Translation
Choi, H. S., & Frangioni, J. V. (2010) · Molecular Imaging · doi:10.2310/7290.2010.00031 · Cited by 351
Self-citationTanaka, E., Choi, H. S., Fujii, H., Bawendi, M. G., & Frangioni, J. V. (2006) · Annals of Surgical Oncology · doi:10.1245/s10434-006-9194-6 · Cited by 262
Self-citationPolom, K., Murawa, D., Rho, Y., Nowaczyk, P., Hünerbein, M., & Murawa, P. (2011) · Cancer · doi:10.1002/cncr.26087 · Cited by 251
“Like ICG, those probes that have a hydrodynamic diameter of 10 nm may potentially pass the SLN,57 but those that are bigger may cause a delay in labeling the SLN.4 Although its anionic properties allow a high uptake of ICG by the lymphatic system, the problem of short retention time was evident in the earlier experime…”
BackgroundMethodInfluentialMieog, J. S. D., Troyan, S. L., Hutteman, M., Donohoe, K. J., van der Vorst, J. R., Stockdale, A., Liefers, G.-J., Choi, H. S., Gibbs-Strauss, S. L., Putter, H., et al. (2011) · Annals of Surgical Oncology · doi:10.1245/s10434-011-1566-x · Cited by 249
“, brightness) 3-fold and also results in a final hydrodynamic diameter (*7 nm) that is better retained in the SLN.(15)”
InfluentialSelf-citationIndocyanine green fluorescence in second near-infrared (NIR-II) window
Starosolski, Z., Bhavane, R., Ghaghada, K. B., Vasudevan, S. A., Kaay, A., & Annapragada, A. (2017) · PLOS ONE · doi:10.1371/journal.pone.0187563 · Cited by 220
Quantitative Imaging of Lymphatic Function with Liposomal Indocyanine Green
Proulx, S. T., Luciani, P., Derzsi, S., Rinderknecht, M., Mumprecht, V., Leroux, J.-C., & Detmar, M. (2010) · Cancer Research · doi:10.1158/0008-5472.can-10-0271 · Cited by 212
Nanotechnology Applications in Surgical Oncology
Singhal, S., Nie, S., & Wang, M. D. (2010) · Annual Review of Medicine · doi:10.1146/annurev.med.60.052907.094936 · Cited by 190
“Frangioni and colleagues (47) have developed an operational prototype designed specifically for use during large animal surgery.”
BackgroundMethodClinical Implications of Near-Infrared Fluorescence Imaging in Cancer
Kosaka, N., Ogawa, M., Choyke, P. L., & Kobayashi, H. (2009) · Future Oncology · doi:10.2217/fon.09.109 · Cited by 179
“ICG has a moderate-affinity binding site on human serum albumin (HSA), and thus noncovalently forms a complex (70 kDa) with HSA after intravenous injection [17].”
BackgroundMérian, J., Gravier, J., Navarro, F., & Texier, I. (2012) · Molecules · doi:10.3390/molecules17055564 · Cited by 174
“suitable for lymph node imaging, since nano-objects, especially lipid-based ones [23,24], are preferentially retained in lymph nodes (demonstrated in different animal models, from rodents to pig [19,25–28]), in contrast to low molecular weight fluorescent dyes, more easily washed and”
BackgroundBradbury, M. S., Phillips, E., Montero, P. H., Cheal, S. M., Stambuk, H., Durack, J. C., Sofocleous, C. T., Meester, R. J. C., Wiesner, U., & Patel, S. (2013) · Integrative Biology · doi:10.1039/c2ib20174g · Cited by 174
Li, D., Schreiber, C. L., & Smith, B. D. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.202004449 · Cited by 163
Li, Y., Zhang, J., Liu, S., Zhang, C., Chuah, C., Tang, Y., Kwok, R. T. K., Lam, J. W. Y., Ou, H., Ding, D., et al. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202102213 · Cited by 88
Photophysical Properties of Indocyanine Green in the Shortwave Infrared Region
Cosco, E. D., Lim, I., & Sletten, E. M. (2021) · ChemPhotoChem · doi:10.1002/cptc.202100045 · Cited by 79
Metadata
- Authors
- Ohnishi, S., Lomnes, S. J., Laurence, R. G., Gogbashian, A., Mariani, G., & Frangioni, J. V.
- Venue
- Molecular Imaging
- Publisher
- SAGE Publications
- Published
- 2005-07-01
- Volume
- 4
- Issue
- 3
- Pages
- 172-81
- ISSN
- 1535-3508 (ISSN-L)
- 1536-0121
- OpenAlex
- W2164624417
- Cited by
- 210
- References
- 24
- FWCI
- 6.67
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.