Abstract
Physical support of lower limbs during sit-to-stand and stand-to-sit transfers is important for an independent life of paraplegic patients. The purpose of this study is, therefore, to realize the control method of complete paraplegic patients during sit-to-stand and stand-to-sit transfers by using a 'robot suit HAL'. It is the most challenging issue because the HAL should start supporting the wearer's motions synchronizing his/her intention. Our proposed algorithm infers the intention based on a preliminary motion that is observed just before a desired motion so the patient could start the sit-to-stand or stand-to-sit transfers without any operation. When the HAL detects the intention to stand up and sit down, the HAL starts to support the wearer's weight and to control their body posture for stability during their transfer. The proposed algorithms embedded in the HAL were applied to a complete spinal cord injury patient in a clinical trial to confirm the effectiveness. The experimental results indicate that the proposed algorithms could support his sit-to-stand and stand-to-sit transfers safely and conveniently by keeping his stability and by reflecting his intentions. Consequently, we confirmed that the proposed method successfully supported the sit-to-stand and stand-to-sit transfers of the complete paraplegic patient with the HAL.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Assistance from exoskeletons enable these patients to regain the ability to stand up, sit down, and walk, just as an able-bodied person [14], [15].”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [14]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“With a built-in multisensor system, an exoskeleton can acquire wearer's motion intensions and accordingly assist the wearer's motion.”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [14]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Central programming of postural movements: adaptation to altered support-surface configurations
Horak, F. B., & Nashner, L. M. (1986) · Journal of Neurophysiology · doi:10.1152/jn.1986.55.6.1369 · Cited by 2,435
Biped walking pattern generation by using preview control of zero-moment point
Kajita, S., Kanehiro, F., Kaneko, K., Fujiwara, K., Harada, K., Yokoi, K., & Hirukawa, H. (2004) · 2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422) · doi:10.1109/robot.2003.1241826 · Cited by 2,104 · cited 1×
“In the field of a humanoid robots, many control strategies for balance maintenance have been proposed [22–26].”
BackgroundPostural Stability of Biped Robots and the Foot-Rotation Indicator (FRI) Point
Goswami, A. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922066376 · Cited by 576 · cited 2×
“The ZMP also corresponds to the COP [16–18].”
BackgroundMethodIntention-based walking support for paraplegia patients with robot suit HAL
Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y. (2007) · Advanced Robotics · doi:10.1163/156855307781746061 · Cited by 474 · cited 1×
“1 has been developed to physically support the patient as well as a healthy person [2–5].”
BackgroundSelf-citationIntention-Based Walking Support for Paraplegia Patients with Robot Suit HAL
Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y. (2010) · Climbing and Walking Robots · doi:10.5772/8835 · Cited by 400
Self-citationPower assist method based on Phase Sequence and muscle force condition for HAL
Kawamoto, H., & Sankai, Y. (2005) · Advanced Robotics · doi:10.1163/1568553054455103 · Cited by 381 · cited 1×
“We have proposed a ‘phase sequence’ concept that divides a sequence of a functional motion into motion elements in a short-term phase in order to comprehend and reconstruct a desired motion [5].”
BackgroundSelf-citationThe influence of chair height on lower limb mechanics during rising
Rodosky, M. W., Andriacchi, T. P., & Andersson, G. B. J. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070215 · Cited by 337
Lee, S., & Sankai, Y. (2003) · IEEE/RSJ International Conference on Intelligent Robots and System · doi:10.1109/irds.2002.1043967 · Cited by 291 · cited 1×
“1 has been developed to physically support the patient as well as a healthy person [2–5].”
BackgroundSelf-citationKinesthetic reference for human orthograde posture
Gurfinkel, V. S., Ivanenko, Y. P., Levik, Y. S., & Babakova, I. A. (1995) · Neuroscience · doi:10.1016/0306-4522(95)00136-7 · Cited by 230
Locomotion Control of a Biped Robot Using Nonlinear Oscillators
Aoi, S., & Tsuchiya, K. (2005) · Autonomous Robots · doi:10.1007/s10514-005-4051-1 · Cited by 175 · cited 1×
“In the field of a humanoid robots, many control strategies for balance maintenance have been proposed [22–26].”
Background
Cited by
Items 201–295 of 295
Innovative Structural Design and Simulation Analysis of Dual-arm Mobile Nursing Robot
Zhang, L., Wang, S., & Miao, X. (2020) · International Conference on Artificial Intelligence and Information Systems (ICAIIS) · doi:10.1109/icaiis49377.2020.9194859 · Cited by 3
“Therefore, the nursing robot must be designed and studied in combination with the advantages of rehabilitation equipment and robot [4].”
BackgroundPrediction of Sit-to-Stand Time Using Trunk Angle and Lower Limb EMG for Assistance System
INOUE, T., & Matsuo, R. (2020) · IEEE International Conference on Artificial Intelligence in Engineering and Technology (IICAIET) · doi:10.1109/iicaiet49801.2020.9257818 · Cited by 3
“With increasing aging population, research and development of devices that assist elderly people with the sitto-stand movement have received significant attention [1–4]; this is because the sit-to-stand movement is frequently used in daily life.”
BackgroundTrajectory planning of the nursing robot based on the center of gravity for aluminum alloy structure
Zhang, L., Gao, H., Xu, H., & Jing, S. (2021) · REVIEWS ON ADVANCED MATERIALS SCIENCE · doi:10.1515/rams-2021-0060 · Cited by 3
“When assisting medical staff to carry out rehabilitation care for patients, the lifting and transferring of patients is the most physical and dangerous task [6], especially in the case of shortage of med-”
BackgroundLi, J., Shen, B., Bai, F., Chew, C., & Teo, C. L. (2013) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2013.6618042 · Cited by 3
“Such commercialized systems are like HAL (Cyberdyne, Japan) [11], ReWalk (Argo Medical, Israel) [12], and eLEGS (Berkeley Bionics, USA) [13].”
BackgroundA human motion prediction algorithm based on HSMM for SIAT's exoskeleton
Wang, M., Wu, X., Liu, D.-X., & Wang, C. (2016) · Chinese Control Conference (CCC) · doi:10.1109/chicc.2016.7553959 · Cited by 3
Rukina, N. N., Kuznetsov, A. N., Борзиков, В. В., Komkova, O. V., & Belova, A. N. (2016) · Современные технологии в медицине · doi:10.17691/stm2016.8.4.28 · Cited by 3
“Apart from walking, of patient’s capacity to sit down and stand up in the exoskeleton was estimated in some cases; for this purpose angles in the pelvic and knee joints [46], as well as pressure of the arms on the wheel-chair handles during these maneuvers were used [20, 21].”
BackgroundMethodExperimental evaluation of an assist chair for sit-to-stand on speed of flipping up a seat of chair
Tyler, N., Suda, A., ONISHI, H., Muromaki, T., & Watanabe, T. (2017) · International Conference on Intelligent Informatics and Biomedical Sciences (ICIIBMS) · doi:10.1109/iciibms.2017.8279743 · Cited by 3
Arm Motion Classifiction Based on sEMG and Angle Signal for A Lower Limb Exoskeleton Control System
Zhang, L., Guo, Z., Wang, C., Yuan, Y., & Wu, X. (2019) · China Symposium on Cognitive Computing and Hybrid Intelligence (CCHI) · doi:10.1109/cchi.2019.8901935 · Cited by 3
McKibben type pneumatic artificial muscle model based on rubber physical characteristics
Hayato, Y. A. S. E., SASAKI, D., KADOWAKI, J., & Yusaku, B. A. B. A. (2022) · Transactions of the JSME (in Japanese) · doi:10.1299/transjsme.21-00286 · Cited by 3
Gait Rehabilitation with Exoskeletons
Federici, S., Meloni, F., & Bracalenti, M. (2018) · Springer eBooks · doi:10.1007/978-3-319-14418-4_80 · Cited by 3
Design and Performance Evaluation of a Knee Assist Exoskeleton Based on Bowden Cables Transmission
Sun, Q., Feng, W., Chen, H., Wang, Z., Cui, L., & Ren, W. (2025) · International Conference on Robotics, Control and Automation (ICRCA) · doi:10.1109/icrca64997.2025.11011234 · Cited by 2
Tsukahara, A., Urata, T., Ito, Y., Unde, J., & Hasegawa, Y. (2025) · IEEE Access · doi:10.1109/access.2025.3602438 · Cited by 2
Self-citationChaichaowarat, R. (2026) · IEEE Access · doi:10.1109/access.2025.3650402 · Cited by 2
Mukherjee, G. (2014) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 2
Belogusev, V., & Егоров, А. В. (2019) · Istrazivanja i projektovanja za privredu · doi:10.5937/jaes17-20367 · Cited by 2
“Compared to traditional physical therapy, auxiliary rehabilitation with an exoskeleton has several advantages, which consist in reducing the working time of therapists, allowing a patient to conduct intensive rehabilitation trainings and providing a quantitative assessment of the level of recovery by measuring strengt…”
BackgroundNajafabadi, A. H., Amini, S., & Farahmand, F. (2021) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119211003370 · Cited by 2
A Whole-Body Wearable Soft Robot with Series Inflatable Actuator
Yamamoto, T., & Suzuki, K. (2017) · The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec) · doi:10.1299/jsmermd.2017.1a1-i08 · Cited by 2
A Hip Active Lower Limb Support Exoskeleton for Load Bearing Sit-To-Stand Transfer
Zhou, J., Zeng, Q., Tang, B., Jing, L., Xiang, K., & Pang, M. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-13822-5_3 · Cited by 2
Guo, Q., & Guo, J. (2025) · International Conference on Control and Intelligent Robotics (ICCIR) · doi:10.1145/3757940.3757958 · Cited by 2
“During the rehabilitation process of hemiplegic patients— caused by stroke, spinal cord injury, or cerebral infarction—lower limb motor impairments have become one of the most common functional disorders, severely affecting the patients’ daily lives [1] [2] [3].”
FAT based adaptive control for a lower extremity rehabilitation device: Simulation results
Li, J., Shen, B., & Chew, C. (2013) · IEEE/ASME International Conference on Advanced Intelligent Mechatronics · doi:10.1109/aim.2013.6584196 · Cited by 2
“Such commercialized systems are like HAL (Cyberdyne, Japan) [8], ReWalk (Argo Medical, Israel) [9], and eLEGS (Berkeley Bionics, USA) [10].”
BackgroundMotion-Assist Arm with a Passive Joint for an Upper Limb
KOZUKA, H., Uchijima, D., & TACHIYA, H. (2020) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2020.p0183 · Cited by 2
Jun, M., Jeong, H., & Ohno, Y. (2014) · Advances in Mechanical Engineering · doi:10.1177/1687814020938899 · Cited by 2
Control of Foot Trajectory in Perception-Assist with a Power-Assist Robot
Kiguchi, K., Yokomine, Y., Okada, N., & Hayashi, Y. (2013) · International Conference on Robot, Vision and Signal Processing · doi:10.1109/rvsp.2013.58 · Cited by 2
“Control of Foot Trajectry in Perception-Assist with a Power-Assist Robot Kazuo Kiguchi, Yutaka Yokomine, Nobuhiro Okada Dept. of Mechanical Engineering Kyushu University Fukuoka, Japan kiguchi@mech.kyushu-u.ac.jp Yoshiaki Hayashi Dept. of Advanced Technology Fusion Saga University Saga,…”
MethodDesign of a hybrid spherical manipulator for lower limb exoskeleton applications
Sadeqi, S. (2017) · Summit (Simon Fraser University) · Cited by 2
視野共有システムを用いた心肺蘇生法の訓練効果( 教育・訓練・協調)
朋子, 米., 悠希, 橋., 大祐, 近., 真隆, 丹., 博幸, 飯., 英由樹, 安., & 太郎, 前. (2011) · 日本バーチャルリアリティ学会論文誌 · doi:10.18974/tvrsj.16.4_623 · Cited by 2
Dehghani-Sanij, A. A., & Martínez-Hernández, U. (2022) · Springer eBooks · doi:10.1007/978-3-031-07555-1_6 · Cited by 2
Design And Development of A Powered Pediatric Lower-limb Orthosis
Laubscher, C. A. (2020) · EngagedScholarship @ Cleveland State University (Cleveland State University) · Cited by 2
Desenvolvimento de barra de apoio modular removível para indivíduos com aparelho locomotor acometido
Assad, D. A. B. (2013) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.82.2013.tde-23052013-102022 · Cited by 2
A powered lower limb exoskeleton supplemented with fes for gait assistance in paraplegic patients
Quintero, H. (2012) · Cited by 2
Modeling Human Dynamics for Powered Exoskeleton Control
Smith, A. (2019) · uO Research (University of Ottawa) · doi:10.20381/ruor-24105 · Cited by 2
ROSAPL: towards a heterogeneous multi‐robot system and Human interaction framework
Roselló, E. B. (2014) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 2
Skill-Assist Arm Using Passive Joints to Aid Spatial Movement of Human Limbs
KOZUKA, H., & TACHIYA, H. (2024) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2024.3504291 · Cited by 1
Development of Lower Limb Exoskeleton Actuatorless Mechanism to Support Standing Motion
Nakamura, K., Tsukamoto, K., & Saga, N. (2021) · Journal of the Robotics Society of Japan · doi:10.7210/jrsj.39.545 · Cited by 1
Analysis of the Sit-to-Stand Movement Based on Dynamic Stability
Fang, G., Gong, P., Xiang, K., Luo, J., & Pang, M. (2023) · International Conference on Electrical Engineering, Control and Robotics (EECR) · doi:10.1109/eecr56827.2023.10150046 · Cited by 1
“[2] through joint angle, center of pressure (COP), and ground reaction forces divided the human STS movement into three phases.”
BackgroundZheng, J. Y., Jiang, M., Meng, Q., Sugahara, Y., Ceccarelli, M., & Takeda, Y. (2025) · Robotica · doi:10.1017/s0263574725102555 · Cited by 1
Wang, T., Shima, K., & Ohno, Y. (2026) · ACM Transactions on Human-Robot Interaction · doi:10.1145/3815170 · Cited by 1
Assist-as-Needed Control of a Chair-Type Device for Sit-to-Stand Assistance
Jiang, M., Kim, S., Zheng, J., Ohkubo, T., & Takeda, Y. (2026) · Mechanisms and machine science · doi:10.1007/978-3-032-35970-4_27 · Cited by 1
Kinematics Characteristic of Exoskeleton Walking Robot for Older People
Chen, Y., Lin, S. Y., Li, R. H., & Zhang, L. D. (2014) · Applied Mechanics and Materials · doi:10.4028/www.scientific.net/amm.644-650.167 · Cited by 1
“Furthermore, the exoskeleton walking robot can be actuated actively to combine the robot power and the human intelligence [7-9] .”
BackgroundKinematic Modelling of FES Induced Sit-to-stand Movement in Paraplegia
Ahmed, M., Huq, M. S., & Ibrahim, B. S. K. K. (2017) · International Journal of Electrical and Computer Engineering (IJECE) · doi:10.11591/ijece.v7i6.pp3060-3069 · Cited by 1
“[31] models which makes it more accurate and flexible; accurate in the sense that it accommodates addition joint i.”
BackgroundA Mobile Exoskeleton Control System Using Electromyographic Signals from Human Muscles
Khoruzhko, M. A., Sesekin, G. N., Болдырева, Н. В., Николаевич, Ш. М., Kastalskiy, I. A., Миронов, В. И., Pimashkin, A. S., & Kazantsev, V. (2017) · Современные технологии в медицине · doi:10.17691/stm2017.9.4.20 · Cited by 1
“robotic ankle control [16], sit-to-stand posture change [13], or control of the upper limb muscle signals [18] have already been designed.”
Kinematics of Sit-to-Stand Task for Knee Osteoarthritis Patients
Bhardwaj, S., Khan, A. A., & Muzammil, M. (2019) · Lecture notes in mechanical engineering · doi:10.1007/978-981-13-6577-5_40 · Cited by 1
Integrated Wheelchair-Compatible Support System for Sit-To-Stand Movements Support
Shiraishi, R., Kawamoto, H., & Sankai, Y. (2019) · Journal of Medical Devices · doi:10.1115/1.4044001 · Cited by 1
Self-citationAhmed, M., Huq, M. S., Ibrahim, B. S. K. K., Jalo, S. A., & Elhassan, G. (2019) · IEEE Conference on Systems, Process and Control · doi:10.1109/icspc47137.2019.9068085 · Cited by 1
A Kinematically Constrained Kalman Filter for Sensor Fusion in a Wearable Origami Robot
Yumbla, E. Q., Li, D., Nibi, T. M., Aukes, D. M., & Zhang, W. (2023) · ASME Letters in Dynamic Systems and Control · doi:10.1115/1.4056986 · Cited by 1
Robust Finite-Time Convergence Control for a Knee Rehabilitation Robot
Yang, R., Zhou, J., Yang, Q., & Song, R. (2019) · International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm.2019.8834250 · Cited by 1
“To guarantee the accuracy of trajectory tracking of patient-passive training, various control algorithms have been proposed, including PD controller [6], a cascaded PID”
MethodData Acquisition System for Measurement of Biomechanical Variables in Sit-to-Stand Task
Bhardwaj, S., Khan, A. A., & Muzammil, M. (2020) · Lecture notes in mechanical engineering · doi:10.1007/978-981-15-8704-7_11 · Cited by 1
Ahmed, M., Huq, M. S., Ibrahim, B. S. K. K., Tahir, N. M., Ahmed, Z., & Elhassan, G. (2021) · Lecture notes in electrical engineering · doi:10.1007/978-981-33-4597-3_38 · Cited by 1
Evaluation of Assistance System to Predict Sit-to-stand Speed using Trunk Angle and Lower Limb EMG
INOUE, T., Uehata, K., & Tomoda, C. (2021) · IEEE International Conference on Artificial Intelligence in Engineering and Technology (IICAIET) · doi:10.1109/iicaiet51634.2021.9573655 · Cited by 1
Parkinson's disease and Dual-Task: Implications on motor and postural control
Fernandes, Â. (2015) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/jv1w-aq29 · Cited by 1
Estratègies de control d'un exosquelet en el procés d'aixecar-se
Morell, P. G., & Josep, T. C. (2018) · RECERCAT (Consorci de Serveis Universitaris de Catalunya) · Cited by 1
Development of knee joint angle trajectory tracking for leg support mechanism
Wan Salleh, W. M. S. (2015) · UTHM Institutional Repository (Universiti Tun Hussein Onn Malaysia) · Cited by 1
Stratégies de commandes assistives pour les exosquelettes des membres inférieurs
Huo, W. (2016) · theses.fr (ABES) · doi:10.70675/816abd75z5d79z41c3zb8e3zfffcb3847558 · Cited by 1
Design of Wearable Power Assist Wear for Low Back Support Using Pneumatic Actuators
李, 向. (2013) · Institutional Repositories DataBase (IRDB)
Design of a Rise Support to be integrated in the HOBBIT Robot
Pesliakas, C., & José, G. (2014) · Lund University Publications Student Papers (Lund University)
Kinematics modeling and simulation to assistant robot based on ADAMS
Wang, Z., Zhou, P., Ji, X., & Liu, Y. (2012) · International Conference on Measurement, Information and Control · doi:10.1109/mic.2012.6273489
“Motion controls to an assistant robot are achieved through controlling the servo motor installed on both sides of the hip and knee [7][8].”
MethodA scenario-based knowledge-driven approach for concept design of assistive robots
Tanaka, H., Wakita, Y., & Matsumoto, Y. (2015) · IEEE RO-MAN · doi:10.1109/roman.2015.7333689
Fernandes, Â., Sousa, A. S. P., Rocha, N., & Tavares, J. M. R. S. (2015) · Instituto Politécnico do Porto · doi:10.13140/2.1.4849.2325
Development of robotic lower-limb prosthetic and orthotic devices
Thapa, S. (2015) · W. S. Hoole Special Collections Library Manuscript Collections
Kiguchi, K., & Yokomine, Y. (2014) · The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec) · doi:10.1299/jsmermd.2014._3a1-q05_1
Passive Exoskeletons with Smart Mechanics to Support Wheelchair-based Locomotion
Suzuki, K., Sasaki, K., Eguchi, Y., & Shimokakimoto, T. (2015) · The Abstracts of the international conference on advanced mechatronics toward evolutionary fusion of IT and mechatronics ICAM · doi:10.1299/jsmeicam.2015.6.115
Electrical stimulation feedback for gait control of walking simulator
Li, M., Yuan, Z., Aoyama, T., & Hasegawa, Y. (2017) · IEEE-RAS International Conference on Humanoid Robots (Humanoids) · doi:10.1109/humanoids.2017.8246963
“used a display screen to show the angle of the joint and the change of the CoG in rehabilitation training [9].”
MethodSelf-citationLearning discriminative intention predictors for sit-to-stand assistance
石倉, 裕., Matsubara, T., Sugimoto, K., Kato, Y., INOUE, T., & Ozawa, J. (2017) · IEEE/SICE International Symposium on System Integration (SII) · doi:10.1109/sii.2017.8279347
“For sit-to-stand assistance, the intention to stand up is predicted from electromyography (EMG) and motion sensors [4]–[6].”
BackgroundThe development of an assistive chair for elderly with sit to stand problems
Lu, H. (2016) · University of Bedfordshire Repository (University of Bedfordshire)
Electric Stimulation based Weight Discrimination for Paraplegic Wearing Exoskeleton
Li, M., Wang, X., Aoyama, T., & Hasegawa, Y. (2018) · IEEE International Conference on Intelligence and Safety for Robotics (ISR) · doi:10.1109/iisr.2018.8535936
“Tukahara developed a center of gravity feedback system which provides joint angels and position of COG using a monitor and an earphone for rehabilitation [9].”
BackgroundSelf-citationReproduction of human dynamic stability in cooperation with human controller model
Yamanaka, Y., Matsumoto, S., & YOSHIDA, K. (2019) · Artificial Life and Robotics · doi:10.1007/s10015-019-00560-y
“Cooperative behavior between a human operator and an artificial controlled device appears in many applications for such as care of elderly individuals [15, 17, 23], assis‑ tive walking [8, 14, 21] and cooperative handling [1, 20].”
BackgroundNonlinear robust control of functional electrical stimulation system for paraplegia
Ahmed, M. S. (2019) · UTHM Institutional Repository (Universiti Tun Hussein Onn Malaysia)
Wu, X., Guo, D., Wang, J., Zhang, J., & Chen, W. (2021) · IEEE Conference on Industrial Electronics and Applications (ICIEA) · doi:10.1109/iciea51954.2021.9516173
Klimenko, A., Melnik, E. V., & Kozlovsky, A. V. (2021) · Lecture notes in networks and systems · doi:10.1007/978-3-030-90321-3_46
Design and simulation of a lower limb exoskeleton rehabilitation robot
Qiao, W., Tong, Y., & Zhang, Z. (2022) · International Conference on Control and Intelligent Robotics (ICCIR) · doi:10.1145/3548608.3559176
“The HAL exoskeleton robot is composed of lower limb mechanical mechanism and computer control system, sensors and actuators.”
BackgroundInfluentialGuo, Y., Dagnino, G., & Yang, G. (2023) · Innovative Medical Devices. · doi:10.1007/978-981-99-7317-0_1
The Metabolic Cost Analysis of Human Walking with a Robotic Lower-limb Exoskeleton
Zhang, S., Wang, W., Wei, W., Zhang, Z., & Ge, W. (2024) · Journal of Circuits Systems and Computers · doi:10.1142/s0218126625500331
Alampay, M. J. P., Jiang, M., & Takeda, Y. (2025) · Mechanisms and machine science · doi:10.1007/978-3-031-91151-4_46
Iwamoto, K., Yamasaki, K., & Shibata, T. (2025) · IEEE RO-MAN · doi:10.1109/ro-man63969.2025.11217647
“Wearable gait support robots, such as HAL[2] and Wel-walk, have been developed; however, their use is primarily limited to rehabilitation facilities, with restrictions on daily life applications.”
Intent Detection Method and Assistive Device Development for Supporting Sit-to-Stand
Zhen, J., Meng, Q., & Jiang, M. (2024) · DuEPublico (University of Duisburg-Essen) · doi:10.17185/duepublico/82601
Additional file 1 of Real-time motion onset recognition for robot-assisted gait rehabilitation
Haji Hassani, R., Bannwart, M., Bolliger, M., Seel, T., Brunner, R., & Rauter, G. (2022) · Figshare · doi:10.6084/m9.figshare.19090995
Jun, M., Jeong, H., & Ohno, Y. (2020) · Sage Journals Data · doi:10.25384/sage.c.5055826
Afschrift, M. (2018) · Lirias (KU Leuven)
Exoesqueletos aplicados à indústria : uma revisão da literatura
Urio, M. B. (2019) · Repositório Digital Institucional da UFPR (Universidade Federal do Paraná)
Cardoso, M. P., Franca, A. M. D., & Andrade, R. M. (2025) · International Conference on Advanced Robotics (ICAR) · doi:10.1109/icar65334.2025.11338616
“In addition to these stationary systems, overground devices such as Indego [7] and HAL [8] have gained attention by allowing users greater freedom of movement, favoring training in environments closer to everyday life.”
Prediction of Seat-Off towards Assistance for Sit-to-Stand Movement by RBFN
Behera, B., Baraskar, P., & Orlando, M. F. (2026) · Applied Mechanics and Materials · doi:10.4028/p-0le5tn
“Since the initiation of the STS movement determines the entire motion, predicting the seat-off event is crucial for delivering timely assistance [1-5].”
Akkawutvanich, C., Sharbafi, M. A., & Manoonpong, P. (2025) · International Convention on Rehabilitation Engineering & Assistive Technology · doi:10.1109/i-create67590.2025.11478113
“The mobile exoskeletons promote more physical activities such as sit-to-stand [2] or walking on different terrains [3].”
Parallel Mechanism-Type Skill-Assist Arm Using a Passive-State Actuator to Aid Movement of Limbs
Tanaka, K., KOZUKA, H., & TACHIYA, H. (2026) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2026.3685910
“R ECENTLY, devices that support human limb movement in manual tasks have attracted increasing attention. these Among , power-assist robots capable of generating forces greater than those of humans to support limb motion have been developed[1],[2],[3],[4],[5].”
Adaptive Dressing Assistance using a Dual Arm Robot for Individual Physique and Kyphosis
Kajiwara, T., Yamasaki, K., & Shibata, T. (2026) · Journal of the Robotics Society of Japan · doi:10.7210/jrsj.44.406
Dynamics-Based Models to Benchmark Data-Driven Human Joint Torque Prediction Neural NetworksPreprint
Perera, C. K., Gopalai, A. A., Lim, L. G., & Gouwanda, D. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.7197503
Dynamics-Based Models to Benchmark Data-Driven Human Joint Torque Prediction Neural NetworksPreprint
Perera, C. K., Gopalai, A. A., Lim, L. G., & Gouwanda, D. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.7197505
Conceptual design of walker-exoskeleton (WAL-EX) mechanism for gait rehabilitation and assistance
CELLEK, F., & Kalaycioğlu, B. (2026) · Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · doi:10.1177/09544062261475905
“27,28 Exoskeletons such as ReWalk, 29 REX 30 and Ekso 31 are developed for this purpose.”
Omiya, T., Fujita, Y., Hotta, K., YAMAGUCHI, S., Watanabe, H., Saito, E., Hara, Y., Iwamoto, M., Mayers, T., & Sankai, Y. (2026) · The Tohoku Journal of Experimental Medicine · doi:10.1620/tjem.2026.j097
Self-citationPhysics-Informed Neural Network Design Toward Interpretable and Efficient Joint Moment Prediction
Xu, T., Liang, Y., Feng, L., Liu, L., He, R., To, M. K.-T., & Hu, Y. S. (2026) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2026.3729773
“Accurate estimation of knee moments can provide valuable insights for various applications, including the development of assistive robotics [40], gait analysis [41], and the diagnosis of knee joint diseases [42].”
Zheng, J., Jiang, M., & Takeda, Y. (2026) · Mechanisms and machine science · doi:10.1007/978-3-032-34511-0_9
Lower limb orthoses for persons with spinal cord injury
Lavis, T. D., & Villadelgado, L. C. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-12108-1.00033-9
Sit-to-Stand Assistance for Patients with Parkinson’s Disease Using a Lower-Limb Exoskeleton Robot
Wu, Y.-C., Yu, L.-P., Lee, S.-H., & Chen, C.-T. (2026) · Bioengineering · doi:10.3390/bioengineering13101226
Li, M., Situ, R., Wang, X., Guo, Y., Mareels, I., Tang, X., & Zhou, S. (2026) · Journal of Bionic Engineering · doi:10.1007/s42235-026-01022-5
Metadata
- Authors
- Tsukahara, A., Kawanishi, R., Hasegawa, Y., & Sankai, Y.
- Affiliations
- University of Tsukuba (JP)
- Venue
- Advanced Robotics
- Publisher
- Informa UK Limited
- Published
- 2010-01
- Volume
- 24
- Issue
- 11
- Pages
- 1615-1638
- ISSN
- 0169-1864 (ISSN-L)
- 1568-5535
- OpenAlex
- W2076829227
- Cited by
- 269
- References
- 29
- Citations by year
- 2026: 12 · 2025: 10 · 2024: 10 · 2023: 15 · 2022: 11 · 2021: 21 · 2020: 16 · 2019: 29 · 2018: 20 · 2017: 17 · 2016: 33 · 2015: 17 · 2014: 17 · 2013: 16 · 2012: 12
- FWCI
- 7.74
- Type
- journal article
- Language
- en
- Open access
- Locations
- Advanced Robotics (publishedVersion)
- Institutional Repositories DataBase (IRDB) (publishedVersion)
- Terrestrial Environment Research Center (University of Tsukuba) (submittedVersion)
- Funders
- Ministry of Health, Labour and Welfare
- University of Tsukuba
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- sit-to-stand, complete paraplegia, spinal cord injury, robot suit, lower limb support, intention inference, postural control, postural stability, assistive robotics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.