Sit-to-Stand and Stand-to-Sit Transfer Support for Complete Paraplegic Patients with Robot Suit HAL
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Physical support of lower limbs during sit-to-stand and stand-to-sit transfers is important for an independent life of paraplegic patients. The purpose of this study is, therefore, to realize the control method of complete paraplegic patients during sit-to-stand and stand-to-sit transfers by using a 'robot suit HAL'. It is the most challenging issue because the HAL should start supporting the wearer's motions synchronizing his/her intention. Our proposed algorithm infers the intention based on a preliminary motion that is observed just before a desired motion so the patient could start the sit-to-stand or stand-to-sit transfers without any operation. When the HAL detects the intention to stand up and sit down, the HAL starts to support the wearer's weight and to control their body posture for stability during their transfer. The proposed algorithms embedded in the HAL were applied to a complete spinal cord injury patient in a clinical trial to confirm the effectiveness. The experimental results indicate that the proposed algorithms could support his sit-to-stand and stand-to-sit transfers safely and conveniently by keeping his stability and by reflecting his intentions. Consequently, we confirmed that the proposed method successfully supported the sit-to-stand and stand-to-sit transfers of the complete paraplegic patient with the HAL.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Assistance from exoskeletons enable these patients to regain the ability to stand up, sit down, and walk, just as an able-bodied person [14], [15].”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [14]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“With a built-in multisensor system, an exoskeleton can acquire wearer's motion intensions and accordingly assist the wearer's motion.”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [14]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Central programming of postural movements: adaptation to altered support-surface configurations
Horak, F. B., & Nashner, L. M. (1986) · Journal of Neurophysiology · doi:10.1152/jn.1986.55.6.1369 · Cited by 2,435
Biped walking pattern generation by using preview control of zero-moment point
Kajita, S., Kanehiro, F., Kaneko, K., Fujiwara, K., Harada, K., Yokoi, K., & Hirukawa, H. (2004) · 2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422) · doi:10.1109/robot.2003.1241826 · Cited by 2,104 · cited 1×
“In the field of a humanoid robots, many control strategies for balance maintenance have been proposed [22–26].”
BackgroundPostural Stability of Biped Robots and the Foot-Rotation Indicator (FRI) Point
Goswami, A. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922066376 · Cited by 576 · cited 2×
“The ZMP also corresponds to the COP [16–18].”
BackgroundMethodIntention-based walking support for paraplegia patients with robot suit HAL
Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y. (2007) · Advanced Robotics · doi:10.1163/156855307781746061 · Cited by 474 · cited 1×
“1 has been developed to physically support the patient as well as a healthy person [2–5].”
BackgroundSelf-citationIntention-Based Walking Support for Paraplegia Patients with Robot Suit HAL
Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y. (2010) · Climbing and Walking Robots · doi:10.5772/8835 · Cited by 400
Self-citationPower assist method based on Phase Sequence and muscle force condition for HAL
Kawamoto, H., & Sankai, Y. (2005) · Advanced Robotics · doi:10.1163/1568553054455103 · Cited by 381 · cited 1×
“We have proposed a ‘phase sequence’ concept that divides a sequence of a functional motion into motion elements in a short-term phase in order to comprehend and reconstruct a desired motion [5].”
BackgroundSelf-citationThe influence of chair height on lower limb mechanics during rising
Rodosky, M. W., Andriacchi, T. P., & Andersson, G. B. J. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070215 · Cited by 337
Lee, S., & Sankai, Y. (2003) · IEEE/RSJ International Conference on Intelligent Robots and System · doi:10.1109/irds.2002.1043967 · Cited by 291 · cited 1×
“1 has been developed to physically support the patient as well as a healthy person [2–5].”
BackgroundSelf-citationKinesthetic reference for human orthograde posture
Gurfinkel, V. S., Ivanenko, Y. P., Levik, Y. S., & Babakova, I. A. (1995) · Neuroscience · doi:10.1016/0306-4522(95)00136-7 · Cited by 230
Locomotion Control of a Biped Robot Using Nonlinear Oscillators
Aoi, S., & Tsuchiya, K. (2005) · Autonomous Robots · doi:10.1007/s10514-005-4051-1 · Cited by 175 · cited 1×
“In the field of a humanoid robots, many control strategies for balance maintenance have been proposed [22–26].”
Background
Cited by
Review of assistive strategies in powered lower-limb orthoses and exoskeletons
Yan, T., Cempini, M., Oddo, C. M., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.032 · Cited by 715
“In [42], HAL is used to support a paraplegic patient to perform sit-to-stand and stand-to-sit.”
MethodAn EMG-Based Control for an Upper-Limb Power-Assist Exoskeleton Robot
Kiguchi, K., & Hayashi, Y. (2012) · IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics) · doi:10.1109/tsmcb.2012.2185843 · Cited by 531
Recent developments and challenges of lower extremity exoskeletons
Chen, B., Ma, H., Qin, L.-Y., Gao, F., Chan, K.-M., Law, S.-W., Qin, L., & Liao, W.-H. (2016) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2015.09.007 · Cited by 501
“Assistance from exoskeletons enable these patients to regain the ability to stand up, sit down, and walk, just as an able-bodied person [14,15].”
BackgroundBortole, M., Venkatakrishnan, A., Zhu, F., Moreno, J. C., Francisco, G. E., Pons, J. L., & Contreras-Vidal, J. L. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0048-y · Cited by 347
“Two different control strategies are used with HAL, depending on the treatment purpose and user’s capabilities [19].”
MethodPreliminary Evaluation of a Powered Lower Limb Orthosis to Aid Walking in Paraplegic Individuals
Farris, R. J., Quintero, H. A., & Goldfarb, M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2163083 · Cited by 342
“In [29]–[32], the authors describe control methods for providing assistive maneuvers (sit-to-stand, stand-to-sit, and walking) to paraplegic individuals with the powered lower limb orthosis HAL, which is an emerging commercial device with (in the incarnation utilized in the aforementioned publications) six electric mo…”
Farris, R. J., Quintero, H. A., Murray, S. A., Ha, K. H., Hartigan, C., & Goldfarb, M. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2268320 · Cited by 208
“In [11] and [14], the authors evaluated the ability of a powered lower limb ex-”
BackgroundHa, K. H., Murray, S. A., & Goldfarb, M. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2421052 · Cited by 176
Tsukahara, A., Hasegawa, Y., Eguchi, K., & Sankai, Y. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2364618 · Cited by 174
Self-citationKubota, S., Nakata, Y., Eguchi, K., Kawamoto, H., Kamibayashi, K., Sakane, M., Sankai, Y., & Ochiai, N. (2013) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2012.12.020 · Cited by 165
Self-citationLiu, M., Wang, D., & Huang, H. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2420539 · Cited by 145
Federici, S., Meloni, F., Bracalenti, M., & Filippis, M. L. D. (2015) · Neurorehabilitation · doi:10.3233/nre-151265 · Cited by 143
Tele-impedance based assistive control for a compliant knee exoskeleton
Karavas, N. C., Ajoudani, A., Tsagarakis, N. G., Saglia, J. A., Bicchi, A., & Caldwell, D. G. (2014) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.027 · Cited by 139
State of the Art Lower Limb Robotic Exoskeletons for Elderly Assistance
Kapsalyamov, A., Jamwal, P. K., Hussain, S., & Ghayesh, M. H. (2019) · IEEE Access · doi:10.1109/access.2019.2928010 · Cited by 139
“Moreover, they can help in performing usual daily activities such as standing and sitting similar to healthy people’s performance [29], [30].”
BackgroundSystematic Review on Wearable Lower Extremity Robotic Exoskeletons for Assisted Locomotion
Qiu, S., Pei, Z., Wang, C., & Tang, Z. (2022) · Journal of Bionic Engineering · doi:10.1007/s42235-022-00289-8 · Cited by 133
Robot-assisted gait rehabilitation: From exoskeletons to gait systems
Low, K. H. (2011) · Defense Science Research Conference and Expo (DSR) · doi:10.1109/dsr.2011.6026886 · Cited by 110
Lower-Limb Movement Assistance through Wearable Robots: State of the Art and Challenges
Mohammed, S., Amirat, Y., & Rifaï, H. (2012) · Advanced Robotics · doi:10.1163/016918611x607356 · Cited by 109
“A proportional derivative (PD) feedback, function of the hip, knee and ankle angles (depending on the studied case), with a constant value control to balance the gravity effect is applied to control the leg’s trajectory and/or stabilize the body at the zero moment point [36, 39].”
BackgroundNonlinear disturbance observer based sliding mode control of a human-driven knee joint orthosis
Mohammed, S., Huo, W., Huang, J., Rifaï, H., & Amirat, Y. (2014) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.10.013 · Cited by 102
Control and implementation of a powered lower limb orthosis to aid walking in paraplegic individuals
Quintero, H. A., Farris, R. J., & Goldfarb, M. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975481 · Cited by 88
“In [27-30], the authors describe control methods for providing assistive maneuvers (sit-to-stand, stand-to-sit, and walking) to paraplegic individuals with the powered lower limb orthosis HAL, which is an emerging commercial Control and Implementation of a Powered Lower Limb Orthosis to Aid Walking in Paraplegic Indiv…”
A Method for the Autonomous Control of Lower Limb Exoskeletons for Persons With Paraplegia
Quintero, H. A., Farris, R. J., & Goldfarb, M. (2012) · Journal of Medical Devices · doi:10.1115/1.4007181 · Cited by 97
“, [5-16]), the authors focus on the capacity of their respective systems to provide legged mobility, but do not focus on specifically on control methods that enable the user to autonomously command various movements.”
BackgroundVariable Ankle Stiffness Improves Balance Control: Experiments on a Bipedal Exoskeleton
Uğurlu, B., Doppmann, C., Hamaya, M., Forni, P., Teramae, T., Noda, T., & Morimoto, J. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2015.2448932 · Cited by 97
A deep learning strategy for EMG-based joint position prediction in hip exoskeleton assistive robots
Foroutannia, A., Akbarzadeh-T., M., & Akbarzadeh, A. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.103557 · Cited by 80
A Powered Lower Limb Orthosis for Providing Legged Mobility in Paraplegic Individuals
Quintero, H., Farris, R. J., Hartigan, C., Clesson, I., & Goldfarb, M. T. (2011) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci1701-25 · Cited by 93
Vantilt, J., Tanghe, K., Afschrift, M., Bruijnes, A. K. B. D., Junius, K., Geeroms, J., Aertbeliën, E., Groote, F. D., Lefeber, D., Jonkers, I., et al. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0526-8 · Cited by 93
Gait Event Detection of a Lower Extremity Exoskeleton Robot by an Intelligent IMU
Ding, S., Ouyang, X., Liu, T., Li, Z., & Yang, H. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2871328 · Cited by 87
“should be embedded into the wearer’s insole [5], [7], shoe sole [8] and the exoskeleton’s sole [6], [9], [10] between the”
BackgroundFan, Y., & Yin, Y. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2267741 · Cited by 86
“Although HAL and BLEEX are well suited for walking assistance of healthy pilot, the devices with rigid structure and lower stability may result in discomfort and will easily fall down for poststrokes.”
BackgroundImprovement and quantitative performance estimation of the back support muscle suit
Muramatsu, Y., Umehara, H., & Kobayashi, H. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610133 · Cited by 86
Muramatsu, Y., Kobayashi, H., Sato, Y. S., Jiaou, H., Hashimoto, T., & Kobayashi, H. (2011) · International Journal of Automation Technology · doi:10.20965/ijat.2011.p0559 · Cited by 86
Impedance Modulation Control of a Lower-Limb Exoskeleton to Assist Sit-to-Stand Movements
Huo, W., Moon, H., Alouane, M. A., Bonnet, V., Huang, J., Amirat, Y., Vaidyanathan, R., & Mohammed, S. (2021) · IEEE Transactions on Robotics · doi:10.1109/tro.2021.3104244 · Cited by 85
Toward Design of an Environment-Aware Adaptive Locomotion-Mode-Recognition System
Du, L., Zhang, F., Liu, M., & Huang, H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2208641 · Cited by 65
“One existing approach is to use biomechanical measurements for mode recognition [2], [3], [9], [11].”
MethodActive Impedance Control of a lower limb exoskeleton to assist sit-to-stand movement
Huo, W., Mohammed, S., Amirat, Y., & Kong, K. (2016) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2016.7487534 · Cited by 80
“In terms of STS human motion intention estimation, different approaches have been developed in the literature, ranging from the simple threshold based algorithms to the multisensory based sophisticated ones [3], [5].”
BackgroundMethodTele-Impedance based stiffness and motion augmentation for a knee exoskeleton device
Karavas, N. C., Ajoudani, A., Tsagarakis, N. G., Saglia, J. A., Bicchi, A., & Caldwell, D. G. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6630872 · Cited by 75
“Another alternative for detecting the user’s intent is to utilize electromyographic signals (EMGs) which is a direct measurement from human muscles [4], [7].”
BackgroundNested saturation based control of an actuated knee joint orthosis
Rifaï, H., Mohammed, S., Hassani, W., & Amirat, Y. (2013) · Mechatronics · doi:10.1016/j.mechatronics.2013.09.007 · Cited by 74
Performance evaluation of a lower limb exoskeleton for stair ascent and descent with Paraplegia
Farris, R. J., Quintero, H., & Goldfarb, M. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346326 · Cited by 74
“These include hybrid FES-systems [1-5], which supplement functional electrical stimulation (FES) of leg muscles with a computer-controlled orthosis; and fully powered lower limb exoskeletons [6-12], which utilize electric motors as the”
Gait support for complete spinal cord injury patient by synchronized leg-swing with HAL
Tsukahara, A., Hasegawa, Y., & Sankai, Y. (2011) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2011.6094827 · Cited by 73
“978-1-61284-456-5/11/$26.00 ©2011 IEEE 1737 This approach is an ideal solution to support the lower limbs of paraplegic patients because it utilizes the wearer’s residual functions and operates based on their intention for physical movement.”
BackgroundSelf-citationToward Lower Limbs Functional Rehabilitation Through a Knee-Joint Exoskeleton
Rifaï, H., Mohammed, S., Djouani, K., & Amirat, Y. (2016) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2016.2565385 · Cited by 73
“Using simple control laws for exoskeletons such as the varieties of proportional–integral–derivative (PID) controllers has been commonly used in the literature [5], [6], [17], [18].”
MethodiLeg—A Lower Limb Rehabilitation Robot: A Proof of Concept
Zhang, F., Hou, Z., Cheng, L., Wang, W., Chen, Y., Hu, J. P., Peng, L., & Wang, H. (2016) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2016.2562510 · Cited by 68
“Available: http://www. rexbionics.com [12] A. Tsukahara, R. Kawanishi, Y. Hasegawa, and Y. Sankai, “Sit-to-stand and stand-to-sit transfer support for complete paraplegic patients with robot suit HAL,” Adv.”
BackgroundSynergy-Based Control of Assistive Lower-Limb Exoskeletons by Skill Transfer
Wei, Q., Li, Z., Zhao, K., Kang, Y., & Su, C. (2019) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2019.2961567 · Cited by 68
“Model-based control structure is popular in various exoskeleton applications, the referenced exoskeleton action is obtained by the human– exoskeleton model computation, which requires to model the coupled human–robot dynamics accurately [13].”
BackgroundPuyuelo, G., Cano‐de‐la‐Cuerda, R., Plaza, A., Garcés‐Castellote, E., Sanz‐Merodio, D., Goñi-Arana, A., Ojea, J. I. M., & García, E. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00690-6 · Cited by 66
Wu, C.-H., Mao, H., Hu, J., Wang, T.-Y., Tsai, Y.-J., & Hsu, W. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0355-1 · Cited by 62
“HAL is working with active leg motion and they use an electromyography (EMG) measure to trigger the motion.”
Andrade, R. M., Sapienza, S., & Bonato, P. (2019) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2019.8779432 · Cited by 61
“, Japan) [9], Ekso (Ekso Bionics, Richmond, CA, USA) [10], Indego (Parker Hannifin Corp.”
A lower-limb power-assist robot with perception-assist
Hayashi, Y., & Kiguchi, K. (2011) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975445 · Cited by 54
Probabilistic identification of sit-to-stand and stand-to-sit with a wearable sensor
Martínez-Hernández, U., & Dehghani-Sanij, A. A. (2018) · Pattern Recognition Letters · doi:10.1016/j.patrec.2018.03.020 · Cited by 58
“An angle recognition threshold-crossing method was embedded in the robot suit HAL to assist humans (Tsukahara et al., 2010).”
MethodStanding Mobility Device With Passive Lower Limb Exoskeleton for Upright Locomotion
Eguchi, Y., Kadone, H., & Suzuki, K. (2018) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2018.2799865 · Cited by 58
Molazadeh, V., Zhang, Q., Bao, X., & Sharma, N. (2021) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2021.3089885 · Cited by 57
Chen, C.-F., Du, Z., He, L., Yong-jun, S., Wang, J.-Q., Xu, G., Zhang, Y., Wu, D., & Dong, W. (2019) · IEEE Access · doi:10.1109/access.2019.2953302 · Cited by 55
Chen, B., Zhong, C.-H., Zhao, X., Ma, H., Qin, L., & Liao, W. (2019) · IEEE Access · doi:10.1109/access.2019.2904296 · Cited by 53
Hua, Y., Fan, J., Liu, G., Zhang, X., Lai, M., Li, M., Zheng, T., Zhang, G., Zhao, J., & Zhu, Y. (2019) · IEEE Access · doi:10.1109/access.2019.2904709 · Cited by 52
Liu, X., Zhou, Z., Mai, J., & Wang, Q. (2019) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2019.06.008 · Cited by 51
Ha, K. H., Quintero, H., Farris, R. J., & Goldfarb, M. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6345939 · Cited by 51
“Others have developed fully-powered, electric motor-actuated lower limb exoskeletons without the use of FES [15-22].”
Afschrift, M., Groote, F. D., Schutter, J. D., & Jonkers, I. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-111 · Cited by 50
“Currently, the actuator selection for assistive devices is mainly based on inverse dynamics (ID) calculations of joint moments and joint powers [3-5].”
BackgroundStability of Mina v2 for Robot-Assisted Balance and Locomotion
Mummolo, C., Peng, W. Z., Agarwal, S., Griffin, R. J., Neuhaus, P. D., & Kim, J. H. (2018) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2018.00062 · Cited by 48
A framework for sensorless torque estimation and control in wearable exoskeletons
Uğurlu, B., Nishimura, M., Hyodo, K., Kawanishi, M., & Narikiyo, T. (2012) · IEEE International Workshop on Advanced Motion Control (AMC) · doi:10.1109/amc.2012.6197032 · Cited by 47
“To this end, several research groups developed inspiring systems, such as lower body active orthoses [2] [3], upper extremity power assist systems [4] [5], and full-body wearable exoskeletons [6].”
BackgroundTransformable Wheelchair–Exoskeleton Hybrid Robot for Assisting Human Locomotion
Chaichaowarat, R., Prakthong, S., & Thitipankul, S. (2023) · Robotics · doi:10.3390/robotics12010016 · Cited by 46
“The control method of a wearable robot for the sit-to-stand and stand-to-sit transfers of patients with spinal cord injuries was presented [26].”
Kubota, S., Abe, T., Kadone, H., Shimizu, Y., Funayama, T., Watanabe, H., Marushima, A., Koda, M., Hada, Y., Sankai, Y., et al. (2018) · Journal of Spinal Cord Medicine · doi:10.1080/10790268.2018.1525975 · Cited by 45
Self-citationReal-Time EMG Driven Lower Limb Actuated Orthosis for Assistance As Needed Movement Strategy
Hassani, W., Mohammed, S., & Amirat, Y. (2013) · Robotics: Science and Systems Conference · doi:10.15607/rss.2013.ix.054 · Cited by 42
“In [27, 29], a PD controller is used to stabilize the body of the wearer by guaranteeing balance of the gravity effect.”
MethodA biarticular passive exosuit to support balance control can reduce metabolic cost of walking
Barazesh, H., & Sharbafi, M. A. (2020) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/ab70ed · Cited by 42
Influence of dual-task on sit-to-stand-to-sit postural control in Parkinson's disease
Fernandes, Â., Sousa, A. S. P., Couras, J. F., Rocha, N., & Tavares, J. M. R. S. (2015) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.08.011 · Cited by 42
“As the CNS is responsible for the motor modulation circuits, which are compromised in individuals with PD, there is a decrease in postural control and consequently, repercussions in the performance of tasks, like STSTS sequences [16], [17] and [18].”
BackgroundMechatronic design of a sit-to-stance exoskeleton
Junius, K., Brackx, B., Grosu, V., Cuypers, H., Geeroms, J., Moltedo, M., Vanderborght, B., & Lefeber, D. (2014) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2014.6913902 · Cited by 41
“The ReWalk [9], Ekso [10] and HAL [11] exoskeletons are all full lower limb devices.”
BackgroundAndrade, R. M., & Bonato, P. (2021) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2021.3052014 · Cited by 41
“Overground gait training exoskeletons, on the other hand, such as Indego (Parker Hannifin Corp., USA) [4], HAL (Cyberdyne Inc., Japan) [5], Ekso (Ekso Bionics, USA) [6], Atalante (Wandercraft, France) and others [7], can assist the user to walk while challenging their balance control system [8].”
BackgroundMuscle synergy structure using different strategies in human standing-up motion
Yang, N., An, Q., Yamakawa, H., Tamura, Y., Yamashita, A., & Asama, H. (2016) · Advanced Robotics · doi:10.1080/01691864.2016.1238781 · Cited by 40
“A robotic exoskeleton assistive system was developed to support the user’s standing-upmotion synchronizing his or her intention.[4] In addition, a sit-to-stand trainer which aimed to support or to train sit-to-stand motion was developed based on kinematics, kinetics and EMG patterns of standing-up motion.”
Başer, Ö., KIZILHAN, H., & Kılıç, E. (2020) · Journal of Mechanical Science and Technology · doi:10.1007/s12206-020-0534-4 · Cited by 38
“Power augmentation robots allow the transport of heavy loads with low muscle strength [4], rehabilitation robots improve musculoskeletal function of paralyzed patients [5], and assistive robots provide walking assistance to the elderly or patients [6, 7].”
BackgroundReal-Time Gait Event Detection for a Lower Extremity Exoskeleton Robot by Infrared Distance Sensors
Li, C., He, Y., Chen, T., Chen, X., & Tian, S. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3111212 · Cited by 38
Jatsun, S. F., Савин, С., & Yatsun, A. S. (2017) · Mechanisms and machine science · doi:10.1007/978-3-319-59972-4_22 · Cited by 37
“Publications [12-17] discuss different aspects of sit-to-stand motion, including problems of control.”
BackgroundRobot Assisted Physiotherapy to Support Rehabilitation of Facial Paralysis
Jayatilake, D., Isezaki, T., Teramoto, Y., Eguchi, K., & Suzuki, K. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2279169 · Cited by 37
Ikumi, A., Kubota, S., Shimizu, Y., Kadone, H., Marushima, A., Ueno, T., Kawamoto, H., Hada, Y., Matsumura, A., Sankai, Y., et al. (2016) · Journal of Spinal Cord Medicine · doi:10.1080/10790268.2016.1225913 · Cited by 37
Self-citationA Fully Soft and Passive Assistive Device to Lower the Metabolic Cost of Sit-to-Stand
Lee, H., Kim, S. H., & Park, H. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00966 · Cited by 36
“Exoskeletons traditionally rely on powerful actuators linked to rigid structural components to provide substantial force transfer (Zoss et al., 2006; Tsukahara et al., 2010; Young and Ferris, 2017).”
BackgroundHybrid FES-Exoskeleton Controller to Assist Sit-To-Stand movement
Alouane, M. A., Huo, W., Rifaï, H., Amirat, Y., & Mohammed, S. (2019) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2019.01.032 · Cited by 36
Stairs-ascending/descending assist for a lower-limb power-assist robot considering ZMP
Hayashi, Y., & Kiguchi, K. (2011) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2011.6094783 · Cited by 32
“If the robot judges the tool motion is wrong or dangerous, the robot automatically tries to modify the tool motion by adding additional force to the user’s hand [13]-[16].”
Increasing Payload Capacity of Wearable Robots Using Linear Actuators
Choo, J., & Park, J. H. (2017) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2705091 · Cited by 32
“Ekso GT [9], [10], HAL [11], [12], Walk Assist [13], REX [14], and ReWalk [15], [16] were developed for rehabilitation applications.”
BackgroundBaiden, D., & Ivlev, O. (2013) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2013.6650353 · Cited by 32
Quintero, H., Farris, R. J., Ha, K., & Goldfarb, M. T. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346685 · Cited by 31
“Some of the efforts in this regard include [7-15].”
BackgroundTanaka, H., Yoshikawa, M., Oyama, E., Wakita, Y., & Matsumoto, Y. (2013) · Journal of Robotics · doi:10.1155/2013/608191 · Cited by 31
Sit-to-Stand movement assistance using an actuated knee joint orthosis
Mefoued, S., Mohammed, S., Amirat, Y., & Fried, G. (2012) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290830 · Cited by 31
“Sankai [5] is a bipedal locomotion system developed to assist the paraplegics and elder subjects during different daily activities including sit-to-stand and stand-to-sit movements.”
An overview of transfer nursing robot: Classification, key technology, and trend
Cheng, G., Huang, Y., Zhang, X., Chen, H., & Ota, J. (2024) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2024.104653 · Cited by 30
Sit-to-stand and stand-to-sit assistance for paraplegic patients with CUHK-EXO exoskeleton
Chen, B., Zhong, C.-H., Ma, H., Guan, X., Qin, L.-Y., Chan, K., Law, S. W., Qin, L., & Liao, W. (2017) · Robotica · doi:10.1017/s0263574717000546 · Cited by 30
Design of knee support device based on four-bar linkage and hydraulic artificial muscle
Kittisares, S., Nabae, H., Endo, G., Suzumori, K., & Sakurai, R. (2020) · ROBOMECH Journal · doi:10.1186/s40648-020-00165-2 · Cited by 29
Asker, A., Assal, S. F. M., Ding, M., Takamatsu, J., Ogasawara, T., & Mohamed, A. M. (2017) · Advanced Robotics · doi:10.1080/01691864.2017.1372214 · Cited by 28
“Wearable devices such as exoskeletons [10] are attached directly to the user.”
BackgroundFunctional design for customizing sit-to-stand assisting devices
Rea, P., & Ottaviano, E. (2018) · Journal of Bionic Engineering · doi:10.1007/s42235-017-0006-4 · Cited by 28
An, Q., Ishikawa, Y., Aoi, S., Funato, T., Oka, H., Yamakawa, H., Yamashita, A., & Asama, H. (2015) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2015.7140023 · Cited by 26
“Different from these devices, robotic exoskeleton devices have been also proposed to detect human intention of standing-up motion and to generate compensative torque on their joints [3].”
Tanghe, K., Harutyunyan, A., Aertbeliën, E., Groote, F. D., Schutter, J. D., Vrancx, P., & Nowé, A. (2016) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2016.2530165 · Cited by 26
“Assisted STS with an exoskeleton for fully paraplegic patients is presented by Tsukahara et al. [3].”
MethodOh, J., Cho, G.-Y., & Kim, H. (2025) · Applied Sciences · doi:10.3390/app15073808 · Cited by 23
Lin, C., & Sie, T. (2023) · Actuators · doi:10.3390/act12020055 · Cited by 22
Fernandes, Â., Sousa, A. S. P., Rocha, N., & Tavares, J. M. R. S. (2016) · Motor Control · doi:10.1123/mc.2015-0032 · Cited by 22
Andrade, R. M., Sapienza, S., Fabara, E. E., & Bonato, P. (2021) · International Symposium on Medical Robotics · doi:10.1109/ismr48346.2021.9661558 · Cited by 22
Pan, C.-T., Chang, C., Yang, Y.-S., Yen, C.-K., Liu, C.-C., Lee, C.-L., & Shiue, Y. (2020) · Mechatronics · doi:10.1016/j.mechatronics.2020.102360 · Cited by 21
Proxy-Based Control of Intelligent Assistive Walker for Intentional Sit-to-Stand Transfer
Huang, J., Yan, S., Yang, D., Wu, D., Wang, L., Yang, Z., & Mohammed, S. (2021) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2021.3074800 · Cited by 23
Mazumder, O., Kundu, A. S., Lenka, P., & Bhaumik, S. (2016) · Gait & Posture · doi:10.1016/j.gaitpost.2016.08.010 · Cited by 21
Ajayi, M. O. (2016) · theses.fr (ABES) · doi:10.70675/8118b0bdzca0ez4d48z90cdz3dffb8f1f6ea · Cited by 21
Comparative analysis of iterative LQR and adaptive PD controllers for a lower limb exoskeleton
Jatsun, S. F., Савин, С., & Yatsun, A. S. (2016) · IEEE International Conference on Cyber Technology in Automation, Control, and Intelligent Systems · doi:10.1109/cyber.2016.7574829 · Cited by 20
Achili, B., Madani, T., Daâchi, B., & Djouani, K. (2016) · Neurocomputing · doi:10.1016/j.neucom.2016.01.065 · Cited by 20
Overground Walking With a Transparent Exoskeleton Shows Changes in Spatiotemporal Gait Parameters
Andrade, R. M., Sapienza, S., Mohebbi, A., Fabara, E. E., & Bonato, P. (2023) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2023.3323381 · Cited by 19
Bounded control of an actuated lower limb orthosis
Rifaï, H., Hassani, W., Mohammed, S., & Amirat, Y. (2011) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2011.6160993 · Cited by 19
“For example, a PD coupled to a constant-value control, balancing the gravity when the foot is on the ground, is applied to control the leg’s trajectory of a paraplegic patient and/or stabilize its body in [4].”
BackgroundBiomechanical Changes Following Knee Arthroplasty During Sit-To-Stand Transfers: Systematic Review
Wang, J., Siddicky, S. F., Oliver, T. E., Dohm, M. P., Barnes, C. L., & Mannen, E. M. (2019) · The Journal of Arthroplasty · doi:10.1016/j.arth.2019.05.028 · Cited by 19
Human Walking Pattern Recognition Based on KPCA and SVM with Ground Reflex Pressure Signal
Peng, Z., Cao, C., Liu, Q., & Pan, W. (2013) · Mathematical Problems in Engineering · doi:10.1155/2013/143435 · Cited by 19
Zhou, Z., Liu, X., Jiang, Y., Mai, J., & Wang, Q. (2019) · doi:10.1109/wearracon.2019.8719399 · Cited by 19
“The threshold value needs to be set manually and therefore the final result of motion intention performance will be influenced due to the subjective factors [4], [5].”
BackgroundMotion intent recognition for control of a lower extremity assistive device (LEAD)
Shen, B., Li, J., Bai, F., & Chew, C. (2013) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2013.6618039 · Cited by 19
“HAL utilizes a phase sequence approach which assumes sequential motion of the user and infers the transition to the next motion state based on joint angles and ground reaction force (GRF) information [10].”
BackgroundMethodVariable Grounding Flexible Limb Tracking Center of Gravity for Sit-to-Stand Transfer Assistance
Sugiura, S., Unde, J., Zhu, Y., & Hasegawa, Y. (2023) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2023.3328449 · Cited by 18
Self-citationSirlantzis, K., Larsen, L. B., Kanumuru, L. K., & Oprea, P. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-812487-1.00011-9 · Cited by 18
Design of a Wearable Lower Body Exoskeleton Mechanism for Shipbuilding Industry
Kawale, S. S., & Muthuswamy, S. (2018) · Procedia Computer Science · doi:10.1016/j.procs.2018.07.073 · Cited by 18
Early Detection of the Initiation of Sit-to-Stand Posture Transitions Using Orthosis-Mounted Sensors
Doulah, A., Shen, X., & Sazonov, E. E. (2017) · Sensors · doi:10.3390/s17122712 · Cited by 17
“A wearable robot Hybrid Assistive Limb was developed to provide physical support to patients in their daily tasks utilizing EMG signal [13].”
Method
Metadata
- Authors
- Tsukahara, A., Kawanishi, R., Hasegawa, Y., & Sankai, Y.
- Affiliations
- University of Tsukuba (JP)
- Venue
- Advanced Robotics
- Publisher
- Informa UK Limited
- Published
- 2010-01
- Volume
- 24
- Issue
- 11
- Pages
- 1615-1638
- ISSN
- 0169-1864 (ISSN-L)
- 1568-5535
- OpenAlex
- W2076829227
- Cited by
- 269
- References
- 29
- Citations by year
- 2026: 12 · 2025: 10 · 2024: 10 · 2023: 15 · 2022: 11 · 2021: 21 · 2020: 16 · 2019: 29 · 2018: 20 · 2017: 17 · 2016: 33 · 2015: 17 · 2014: 17 · 2013: 16 · 2012: 12
- FWCI
- 7.74
- Type
- journal article
- Language
- en
- Open access
- Locations
- Advanced Robotics (publishedVersion)
- Institutional Repositories DataBase (IRDB) (publishedVersion)
- Terrestrial Environment Research Center (University of Tsukuba) (submittedVersion)
- Funders
- Ministry of Health, Labour and Welfare
- University of Tsukuba
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- sit-to-stand, complete paraplegia, spinal cord injury, robot suit, lower limb support, intention inference, postural control, postural stability, assistive robotics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.