Design of an electrically actuated lower extremity exoskeleton
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Human exoskeletons add the strength and endurance of robotics to a human's innate intellect and adaptability to help people transport heavy loads over rough, unpredictable terrain. The Berkeley lower extremity exoskeleton (BLEEX) is the first human exoskeleton that was successfully demonstrated to walk energetically autonomous while supporting its own weight plus an external payload. This paper details the design of the electric motor actuation for BLEEX and compares it to the previously designed hydraulic actuation scheme. Clinical gait analysis data was used to approximate the torques, angles and powers required at the exoskeleton's leg joints. Appropriately sized motors and gearing are selected, and put through a thorough power analysis. The compact electric joint design is described and the final electric joint performance is compared with BLEEX's previous hydraulic actuation. Overall, the electric actuation scheme is about twice as efficient and twice as heavy as the hydraulic actuation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)
Zoss, A. B., Kazerooni, H., & Chu, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871087 · Cited by 1,170
Self-citationStair ascent and descent at different inclinations
Riener, R., Rabuffetti, M., & Frigo, C. (2002) · Gait & Posture · doi:10.1016/s0966-6362(01)00162-x · Cited by 744 · cited 1×
“[20], but a more detailed three-dimensional CGA for stair ascent can be found from Duncan et al.”
BackgroundOn the Control of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Kazerooni, H., Racine, J.-L., Huang, L., & Steger, R. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570790 · Cited by 594
Self-citationHuman Robot Interaction via the Transfer of Power and Information Signals
Kazerooni, H. (1990) · IEEE Trans. · Cited by 362
Self-citationPower Assist System HAL-3 for Gait Disorder Person
Kawamoto, H., & Sankai, Y. (2002) · Lecture Notes in Computer Science · doi:10.1007/3-540-45491-8_43 · Cited by 346 · cited 1×
“Tsukuba University in Japan has successfully demonstrated the lightweight power assist device, HAL [ 8 ].”
Human-robot interaction via the transfer of power and information signals
Kazerooni, H. (1990) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/21.52555 · Cited by 338
Self-citationThe Berkeley Lower Extremity Exoskeleton
Kazerooni, H., & Steger, R. (2006) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.2168164 · Cited by 293
Self-citationOn the Biomimetic Design of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Chu, A., Kazerooni, H., & Zoss, A. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570789 · Cited by 258 · cited 2×
“Generally, BLEEX has ankle, knee and hip joints like a person [ 15 ].”
BackgroundMethodSelf-citationDevelopment of active anthropomorphic exoskeletons
Vukobratovic, M., Hristic, D., & Stojiljkovic, Z. (1974) · Medical & Biological Engineering · doi:10.1007/bf02629836 · Cited by 216
Development of power assisting suit for assisting nurse labor
YAMAMOTO, K., HYODO, K., ISHII, M., & MATSUO, T. (2002) · JSME International Journal Series C · doi:10.1299/jsmec.45.703 · Cited by 169
Makinson, B. J. (1971) · doi:10.21236/ad0724797 · Cited by 140
Kazerooni, H., & Guo, J. (1993) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.2899068 · Cited by 119
Self-citationThe human power amplifier technology at the University of California, Berkeley
Kazerooni, H. (1996) · Robotics and Autonomous Systems · doi:10.1016/s0921-8890(96)00045-0 · Cited by 105
Self-citationKirtley, C. (2006) · Medical Entomology and Zoology · Cited by 73
MacDonald, D. A. (1996) · Current Orthopaedics · doi:10.1016/s0268-0890(96)90018-3 · Cited by 69
Hybrid hydraulic-electric power unit for field and service robots
Amundson, K., Raade, J., Harding, N., & Kazerooni, H. (2005) · 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2005.1545452 · Cited by 55 · cited 1×
“A series of high specific power and specific energy power supplies were developed that were small enough to make BLEEX a true field-operational system [13, 14 ].”
BackgroundSelf-citationAnalysis and Design of a Novel Hydraulic Power Source for Mobile Robots
Raade, J. W., & Kazerooni, H. (2005) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2005.850394 · Cited by 34
Self-citationSix degree of freedom joint power in stair climbing
Duncan, J. A., Kowalk, D. L., & Vaughan, C. L. (1997) · Gait & Posture · doi:10.1016/s0966-6362(96)01086-7 · Cited by 30 · cited 1×
“The data presented here is from Riener et al. [20], but a more detailed three-dimensional CGA for stair ascent can be found from Duncan et al. [ 21 ].”
MethodHigh-speed communication network for controls with the application on the exoskeleton
Kim, S., Anwar, G., & Kazerooni, H. (2004) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc.2004.1383630 · Cited by 27
Self-citationAnalysis and design of a novel power supply for mobile robots
Raade, J. W., Kazerooni, H., & McGee, T. G. (2004) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2004.1302496 · Cited by 11 · cited 1×
“A series of high specific power and specific energy power supplies were developed that were small enough to make BLEEX a true field-operational system [13, 14].”
BackgroundSelf-citationDesign of Compact and Lightweight Wearable Power Assist Device
Naruse, K., Kawai, S., Yokoi, H., & Kakazu, Y. (2003) · ASME International Mechanical Engineering Congress and Exposition (IMECE) · doi:10.1115/imece2003-41340 · Cited by 8
Cited by
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327
Reducing the energy cost of human walking using an unpowered exoskeleton
Collins, S. H., Wiggin, M. B., & Sawicki, G. S. (2015) · Nature · doi:10.1038/nature14288 · Cited by 967
Exoskeletons and orthoses: classification, design challenges and future directions
Herr, H. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-21 · Cited by 477
Autonomous exoskeleton reduces metabolic cost of human walking during load carriage
Mooney, L. M., Rouse, E. J., & Herr, H. M. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-80 · Cited by 461
Lower Limb Wearable Robots for Assistance and Rehabilitation: A State of the Art
Huo, W., Mohammed, S., Moreno, J. C., & Amirat, Y. (2016) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2351491 · Cited by 455
Metadata
- Authors
- Zoss, A., & Kazerooni, H.
- Venue
- Advanced Robotics
- Publisher
- Informa UK Limited
- Published
- 2006-01
- Volume
- 20
- Issue
- 9
- Pages
- 967-988
- ISSN
- 0169-1864 (ISSN-L)
- 1568-5535
- OpenAlex
- W2149744701
- Cited by
- 160
- References
- 21
- FWCI
- 2.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.