The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
The Berkeley Lower Extremity Exoskeleton
Abstract
The first functional load-carrying and energetically autonomous exoskeleton was demonstrated at the University of California, Berkeley, walking at the average speed of 1.3m∕s(2.9mph) while carrying a 34kg(75lb) payload. Four fundamental technologies associated with the Berkeley lower extremity exoskeleton were tackled during the course of this project. These four core technologies include the design of the exoskeleton architecture, control schemes, a body local area network to host the control algorithm, and a series of on-board power units to power the actuators, sensors, and the computers. This paper gives an overview of one of the control schemes. The analysis here is an extension of the classical definition of the sensitivity function of a system: the ability of a system to reject disturbances or the measure of system robustness. The control algorithm developed here increases the closed-loop system sensitivity to its wearer’s forces and torques without any measurement from the wearer (such as force, position, or electromyogram signal). The control method has little robustness to parameter variations and therefore requires a relatively good dynamic model of the system. The trade-offs between having sensors to measure human variables and the lack of robustness to parameter variation are described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)
Zoss, A. B., Kazerooni, H., & Chu, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871087 · Cited by 1,170
Self-citationThe relation between force and velocity in human muscle
Wilkie, D. R. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004437 · Cited by 632
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
Lower Limb Wearable Robots for Assistance and Rehabilitation: A State of the Art
Huo, W., Mohammed, S., Moreno, J. C., & Amirat, Y. (2016) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2351491 · Cited by 455
A biologically inspired soft exosuit for walking assistance
Asbeck, A. T., De Rossi, S. M. M., Holt, K. G., & Walsh, C. J. (2015) · The International Journal of Robotics Research · doi:10.1177/0278364914562476 · Cited by 450
A biologically-inspired multi-joint soft exosuit that can reduce the energy cost of loaded walking
Panizzolo, F. A., Galiana, I., Asbeck, A. T., Siviy, C., Schmidt, K., Holt, K. G., & Walsh, C. J. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0150-9 · Cited by 291
Mechanical design of the Hanyang Exoskeleton Assistive Robot(HEXAR)
Kim, W., Lee, H., Kim, D., Han, J., & Han, C. (2014) · 2014 14th International Conference on Control, Automation and Systems (ICCAS 2014) · doi:10.1109/iccas.2014.6988049 · Cited by 47
Metadata
- Authors
- Kazerooni, H., & Steger, R.
- Venue
- Journal of Dynamic Systems, Measurement, and Control
- Publisher
- ASME International
- Published
- 2005-09-17
- Volume
- 128
- Issue
- 1
- Pages
- 14-25
- ISSN
- 0022-0434 (ISSN-L)
- 1528-9028
- OpenAlex
- W2034922363
- Cited by
- 293
- References
- 2
- FWCI
- 5.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Berkeley Lower Extremity Exoskeleton. https://app.cochat.ai/papers/10.1115/1.2168164
- The paper
- Kazerooni, H., & Steger, R. (2006). The Berkeley Lower Extremity Exoskeleton. Journal of Dynamic Systems, Measurement, and Control. https://doi.org/10.1115/1.2168164
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.