Tactile display and vibrotactile pattern recognition on the torso
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
A wirelessly controlled tactile display has been designed, fabricated and tested for use as a navigation aid. The display comprises a 4 × 4 array of vibrating motors that is mounted on a waist band and stimulates the skin across the lower back. Three types of electromechanical actuators were evaluated for use in the display; based on their mechanical performance and power requirements, two of these motors were then used to fabricate tactile displays. The performance of the displays and the wireless tactile control units was assessed experimentally by having subjects identify which of eight possible vibrotactile patterns was presented to the lower back. The results indicated that subjects could recognize the vibrotactile patterns with almost perfect accuracy and that there was no difference between the two types of motor used for the displays. Moreover, the ability to recognize the pattern of vibrotactile stimulation was superior on the back as compared to the forearm. A further experiment confirmed that the tactile display can be used as a navigation aid outdoors and that the vibrotactile patterns presented can be interpreted as directional or instructional cues with almost perfect accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1992) · Applied Ergonomics · doi:10.1016/0003-6870(92)90338-v · Cited by 7,112
Weinstein, S. (1968) · Medical Entomology and Zoology · Cited by 707
Vibrotactile localization on the abdomen: Effects of place and space
Cholewiak, R. W., Brill, J. C., & Schwab, A. (2004) · Perception & Psychophysics · doi:10.3758/bf03194989 · Cited by 300
Spatial Acuity of the Body Surface over the Life Span
Stevens, J. C., & Choo, K. K. (1996) · Somatosensory & Motor Research · doi:10.3109/08990229609051403 · Cited by 279 · cited 1×
“averaging 20–40 mm, as compared to 1 mm on the fingertip [2, 3].”
BackgroundA First Investigation into the Effectiveness of Tactons
Brown, L. M., Brewster, S. A., & Purchase, H. C. (2005) · First Joint Eurohaptics Conference and Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems · doi:10.1109/whc.2005.6 · Cited by 224
Balance prosthesis based on micromechanical sensors using vibrotactile feedback of tilt
Wall, C., Weinberg, M. S., Schmidt, P. B., & Krebs, D. E. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.951518 · Cited by 153 · cited 1×
“11b [13], Bluetooth [14] and infrared wireless [15].”
BackgroundAn instrumentation solution for reducing spatial disorientation mishaps
Rupert, A. H. (2000) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.827409 · Cited by 150
Design of a wearable tactile display
Gemperle, F., Ota, N., & Siewiorek, D. (2002) · Proceedings Fifth International Symposium on Wearable Computers · doi:10.1109/iswc.2001.962082 · Cited by 142 · cited 1×
“11b [13], Bluetooth [14] and infrared wireless [15].”
BackgroundOn the Vibrational Sensitivity in Different Regions of the Body Surface
WILSKA, A. (1954) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1954.tb01139.x · Cited by 124
Virtual environments and advanced interface design
Usoh, M. (1996) · Endeavour · doi:10.1016/0160-9327(96)88424-9 · Cited by 116
Kaczmarek, K. A., & Bach‐y‐Rita, P. (1995) · Cited by 104
van Erp, J. B. F. (2001) · Lecture notes in computer science · doi:10.1007/3-540-44589-7_18 · Cited by 84
Vibrotactile letter reading using a low-resolution tactor array
YANAGIDA, Y., Kakita, M., Lindeman, R. W., Kume, Y., & Tetsutani, N. (2004) · Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems · doi:10.1109/haptic.2004.1287227 · Cited by 73 · cited 1×
“The number and types of tactons that can reliably be perceived is not known, although studies have been conducted on vibrotactile letter recognition [19] and movement perception [20] on the torso.”
Background(2000) · PubMed · Cited by 60
A Psychophysical Study of Sensory Saltation With an Open Response Paradigm
Tan, H., Lim, A., & Traylor, R. (2000) · Dynamic Systems and Control: Volume 2 · doi:10.1115/imece2000-2419 · Cited by 52 · cited 1×
“The number and types of tactons that can reliably be perceived is not known, although studies have been conducted on vibrotactile letter recognition [19] and movement perception [20] on the torso.”
Background(1991) · Annals of Biomedical Engineering · doi:10.1007/bf02367403 · Cited by 42
A wearable tactile sensory aid for profoundly deaf children
Saunders, F. A., Hill, W. A., & Franklin, B. (1981) · Journal of Medical Systems · doi:10.1007/bf02222144 · Cited by 36 · cited 1×
“The auditory prosthesis, known as the Teletactor, used 32 electrodes mounted on the skin overlying the abdomen to represent sound intensity within a given frequency range in the auditory spectrum [8].”
MethodThe Design and Deployment of a Wearable Vibrotactile Feedback System
Lindeman, R. W., Sibert, J. L., Lathan, C., & Vice, J. M. (2004) · International Symposium on Wearable Computers · doi:10.1109/iswc.2004.43 · Cited by 28 · cited 7×
“Some of these tactile displays have been designed so that they can be controlled wirelessly using communication technologies such as IEEE 802.11b [13], Bluetooth [14] and infrared wireless [15].”
BackgroundInfluential
Cited by
Tactile Displays: Guidance for Their Design and Application
Jones, L. A., & Sarter, N. B. (2008) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1518/001872008x250638 · Cited by 561
Self-citationHaptics: The Present and Future of Artificial Touch Sensation
Culbertson, H., Schorr, S. B., & Okamura, A. M. (2018) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-060117-105043 · Cited by 431
Haptic wearables as sensory replacement, sensory augmentation and trainer – a review
Shull, P. B., & Damian, D. D. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0055-z · Cited by 245
“[87] used a 4 x 4 array of vibrotactors along the lower back to guide subjects through a grid of cones outside in a field.”
MethodCsapó, Á., Wersényi, G., Nagy, H., & Stockman, T. (2015) · Journal on Multimodal User Interfaces · doi:10.1007/s12193-015-0182-7 · Cited by 181
Tactile motion instructions for physical activities
Spelmezan, D., Jacobs, M., Hilgers, A., & Borchers, J. (2009) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/1518701.1519044 · Cited by 146
Metadata
- Authors
- Jones, L. A., Lockyer, B., & Piateski, E.
- Venue
- Advanced Robotics
- Publisher
- Informa UK Limited
- Published
- 2006-01
- Volume
- 20
- Issue
- 12
- Pages
- 1359-1374
- ISSN
- 0169-1864 (ISSN-L)
- 1568-5535
- OpenAlex
- W1992414791
- Cited by
- 162
- References
- 18
- FWCI
- 4.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.