Plasma treatment of polydimethylsiloxane
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Plasma treatment of silicone surfaces is a useful way of increasing wettability to improve adhesion and a first step in producing various organosilicon thin-film composites. Despite numerous earlier studies, there is no consensus on the effect of plasma treatment nor on the mechanism of the subsequent hydrophobic recovery. X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM) were used to study the effect of plasma treatments of polydimethylsiloxane elastomer using four different plasma gases: argon, helium, oxygen, and nitrogen. In each case, the surface was oxidized to produce a thin, wettable, brittle silica-like layer. These surfaces progressively recover their hydrophobicity by diffusion of untreated polymer chains through cracks in the treated layer. Angle-resolved XPS detected the untreated, diffused layer and SEM revealed the common occurrence of cracks in the treated layer, although conditions could be found for each gas where the surface becomes completely wettable by water but is free from cracks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wagner, C. D., Davis, L. E., Zeller, M. V., Taylor, J. A., Raymond, R. H., & Gale, L. H. (1981) · Surface and Interface Analysis · doi:10.1002/sia.740030506 · Cited by 2,075
On the aging of oxygen plasma-treated polydimethylsiloxane surfaces
Morra, M., Occhiello, E., Marola, R., Garbassi, F., Humphrey, P., & Johnson, D. (1990) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(90)90038-p · Cited by 477
Activated gas plasma surface treatment of polymers for adhesive bonding
Hall, J. R., Westerdahl, C. A. L., Devine, A. T., & Bodnar, M. J. (1969) · Journal of Applied Polymer Science · doi:10.1002/app.1969.070131006 · Cited by 157
Adaptation of plastic surfaces for tissue culture by glow discharge
Amstein, C. F., & Hartman, P. A. (1975) · Journal of Clinical Microbiology · doi:10.1128/jcm.2.1.46-54.1975 · Cited by 144
Correlation between adhesion hysteresis and phase state of monolayer films
Chaudhury, M. K., & Owen, M. J. (1993) · The Journal of Physical Chemistry · doi:10.1021/j100123a043 · Cited by 110
Self-citation
Cited by
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Bhattacharya, S., Datta, A., Berg, J. M., & Gangopadhyay, S. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.844746 · Cited by 859
Efimenko, K., Wallace, W. E., & Genzer, J. (2002) · Journal of Colloid and Interface Science · doi:10.1006/jcis.2002.8594 · Cited by 757
Materials and Structures toward Soft Electronics
Wang, C., Wang, C., Huang, Z., & Xu, S. (2018) · Advanced Materials · doi:10.1002/adma.201801368 · Cited by 662
Bodas, D., & Khan-Malek, C. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.08.037 · Cited by 600
Metadata
- Authors
- Owen, M. J., & Smith, P. J.
- Venue
- Journal of Adhesion Science and Technology
- Publisher
- Informa UK Limited
- Published
- 1994-01
- Volume
- 8
- Issue
- 10
- Pages
- 1063-1075
- ISSN
- 0169-4243 (ISSN-L)
- 1568-5616
- OpenAlex
- W2063879585
- Cited by
- 410
- References
- 5
- FWCI
- 3.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.