CoChat

Cytocompatibility of UV and visible light photoinitiating systems on cultured NIH/3T3 fibroblasts in vitro

Bryant, Stephanie J., Nuttelman, Charles R., Anseth, Kristi S. · 2000 · Journal of Biomaterials Science, Polymer Edition
Cited by 774

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

This work investigates the cytocompatibility of several photoinitiating systems for potential cell encapsulation applications. Both UV and visible light initiating schemes were examined. The UV photoinitiators included 2,2-dimethoxy-2-phenylacetophenone (Irgacure 651), 1-hydroxycyclohexyl phenyl ketone (Irgacure 184), 2-methyl-1-[4-(methylthio) phenyl]-2-(4-morpholinyl)-1-propanone (Irgacure 907), and 2-hydroxy-1-[4-(hydroxyethoxy)phenyl]-2-methyl-1-propanone (Darocur 2959). The visible light initiating systems included camphorquinone (CQ) with ethyl 4-N,N-dimethylaminobenzoate (4EDMAB) and triethanolamine (TEA) and the photosensitizer isopropyl thioxanthone. A cultured fibroblast cell line, NIH/3T3, was exposed to the photoinitiators at varying concentrations from 0.01% (w/w) to 0.1% (w/w) with and without the presence of initiating light. The results demonstrated that at low photoinitiator concentrations (< or = 0.01% (w/w)), all of the initiator molecules were cytocompatible with the exception of CQ, Irgacure 651, and 4EDMAB which had a relative survival approximately 50% lower than a control. In the presence of low intensity initiating light (approximately 6 mWcm(-2) of 365 nm UV light and approximately 60 mWcm(-2) of 470-490 nm visible light) and initiating radicals, Darocur 2959 at concentrations < or = 0.05% (w/w) and CQ at concentrations < or = 0.01% (w/w) were the most promising cytocompatible UV and visible light initiating systems, respectively. To demonstrate the potential use of cytocompatible photoinitiating systems in cell encapsulation applications, chondrocytes were encapsulated in a photocrosslinked hydrogel using 0.05% (w/w) Darocur 2959 (cytocompatible) and 0.01% (w/w) Irgacure 651 (cyto-incompatible). After photopolymerizing for 10 minutes with approximately 8 mWcm(-2) of 365 nm light, nearly all the chondrocytes survived the process with Darocur 2959 while very few of the chondrocytes survived the process with Irgacure 651.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1163/156856200743805

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 774

Metadata

Authors
Bryant, S. J., Nuttelman, C. R., & Anseth, K. S.
Venue
Journal of Biomaterials Science, Polymer Edition
Published
2000-01
Volume
11
Issue
5
Pages
439-457
ISSN
  • 0920-5063 (ISSN-L)
  • 1568-5624
OpenAlex
W2051920559
Cited by
774
References
18
FWCI
10.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.