Limits of detection for time of flight secondary ion mass spectrometry (ToF-SIMS) and X-ray photoelectron spectroscopy (XPS): detection of low amounts of adsorbed protein
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Characterization of biomaterial surfaces requires analytical techniques that are capable of detecting a wide concentration range of adsorbed protein. This range includes detection of low amounts of adsorbed protein (<10 ng/cm2) that may be present on non-fouling biomaterials. X-ray Photoelectron Spectroscopy (XPS) and Time of Flight Secondary Ion Mass Spectrometry (ToF-SIMS) are surface sensitive techniques capable of detecting adsorbed proteins. We have investigated the lower limits of detection of both XPS and ToF-SIMS on four model substrates each presenting unique challenges for analysis by XPS and ToF-SIMS: mica, poly(tetrafluoroethylene), allyl amine plasma polymer and heptyl amine plasma polymer. The detection limit for XPS ranged from 10 ng/cm2 of fibrinogen (on mica) to 200 ng/cm2 (on allyl amine plasma polymers). The detection limit for ToF-SIMS ranged from 0.1 ng/cm2 of fibrinogen to 100 ng/cm2, depending on the substrate and data analysis. Optimal conditions provided detection limits between 0.1 ng/cm2 and 15 ng/cm2 on all of the substrates used in this study. While both techniques were shown to be effective in detecting protein, the sensitivity of both XPS and ToF-SIMS was shown to be dependent on substrate surface chemistry and the organization of the adsorbed protein film. This study specifically highlights the applicability of ToF-SIMS in the characterization of low level protein adsorption.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wold, S., Esbensen, K., & Geladi, P. (1987) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(87)80084-9 · Cited by 11,606
A User's Guide to Principal Components
Leigh, S., & Jackson, J. E. (1993) · Technometrics · doi:10.2307/1269292 · Cited by 3,332
A Use's Guide to Principal Components
Jackson, J. E. (1991) · Wiley Series in Probability and Statistics · doi:10.1002/0471725331 · Cited by 2,516
Surface and Interfacial Aspects of Biomedical Polymers
(1985) · Springer eBooks · doi:10.1007/978-1-4684-8610-0 · Cited by 1,284
FTIR/ATR for protein adsorption to biomaterial surfaces
Chittur, K. K. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00223-8 · Cited by 410
Wagner, M. S., & Castner, D. G. (2001) · Langmuir · doi:10.1021/la001209t · Cited by 409
Self-citationProtein absorption and ellipsometry in biomaterial research
Elwing, H. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00112-9 · Cited by 298
Characterization of adsorbed protein films by time of flight secondary ion mass spectrometry
Lhoest, J.-B., Wagner, M. S., Tidwell, C. D., & Castner, D. G. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20011205)57:3<432::aid-jbm1186>3.0.co;2-g · Cited by 193
Self-citationBurlingame, A. L., Boyd, R. K., & Gaskell, S. J. (1998) · Analytical Chemistry · doi:10.1021/a1980023+ · Cited by 176
Tidwell, C. D., Castner, D. G., Golledge, S. L., Ratner, B. D., Meyer, K., Hagenhoff, B., & Benninghoven, A. (2001) · Surface and Interface Analysis · doi:10.1002/sia.1101 · Cited by 165
Self-citationCompetitive protein adsorption as observed by surface plasmon resonance
Green, R. J., Davies, M. C., Roberts, C. J., & Tendler, S. J. B. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00201-4 · Cited by 159
Atomic force microscopy for characterization of the biomaterial interface
Siedlecki, C. A., & Marchant, R. E. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00222-6 · Cited by 110
Welle, A., Grunze, M., & Тур, Д. Р. (1998) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1997.5238 · Cited by 81
Anticoagulant activity of dextran derivatives
de Raucourt, E., Mauray, S., Chaubet, F., Maiga-Revel, O., Jozefowicz, M., & Fischer, A. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199807)41:1<95::aid-jbm12>3.0.co;2-g · Cited by 62
Analysis of proteins adsorbed to glass from human plasma using immunoblotting methods
Mulzer, S. R., & Brash, J. L. (1989) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856290x00035 · Cited by 17
Surface Analysis: X-ray Photoelectron Spectroscopy and Auger Electron Spectroscopy
Turner, N. H., & Schreifels, J. A. (1998) · Analytical Chemistry · doi:10.1021/a19800139 · Cited by 10
Ion/ion chemistry of high-mass multiply charged ions
McLuckey, S. A., & Stephenson, J. L. (1999) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1999)18:1<1::aid-mas1>3.0.co;2-w · Cited by 5
Cited by
Protein Interactions with Polymer Coatings and Biomaterials
Wei, Q., Becherer, T., Angioletti‐Uberti, S., Dzubiella, J., Wischke, C., Neffe, A. T., Lendlein, A., Ballauff, M., & Haag, R. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201400546 · Cited by 743
In vitro assessments of nanomaterial toxicity
Jones, C. F., & Grainger, D. W. (2009) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.03.005 · Cited by 554
Cole, M. A., Voelcker, N. H., Thissen, H., & Griesser, H. J. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.12.026 · Cited by 454
Adhesion of mouse fibroblasts on hexamethyldisiloxane surfaces with wide range of wettability
Wei, J., Yoshinari, M., Takemoto, S., Hattori, M., Kawada, E., Liu, B., & Oda, Y. (2007) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30638 · Cited by 268
Multivariate Analysis of ToF-SIMS Data from Multicomponent Systems: The Why, When, and How
Graham, D. J., & Castner, D. G. (2012) · Biointerphases · doi:10.1007/s13758-012-0049-3 · Cited by 213
Self-citation
Metadata
- Authors
- Wagner, M. S., McArthur, S. L., Shen, M., Horbett, T. A., & Castner, D. G.
- Venue
- Journal of Biomaterials Science, Polymer Edition
- Publisher
- Informa UK Limited
- Published
- 2002-01
- Volume
- 13
- Issue
- 4
- Pages
- 407-428
- ISSN
- 0920-5063 (ISSN-L)
- 1568-5624
- OpenAlex
- W2115640378
- Cited by
- 160
- References
- 17
- FWCI
- 4.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.