CoChat

Preparation and characterization of poly(propylene fumarate-co-ethylene glycol) hydrogels

Suggs, Laura J., Kao, Edmund Y., Palombo, Laurie L., Krishnan, Ravi S., Widmer, Markus S., Mikos, Antonios G. · 1998 · Journal of Biomaterials Science, Polymer Edition
Cited by 84

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

We describe the preparation and bulk characterization of a cross-linked poly(propylene fumarate-co-ethylene glycol), p(PF-co-EG), hydrogel. Eight block copolymer formulations were made varying four different design parameters including: poly(ethylene glycol) (PEG) molecular weight, poly(propylene fumarate) (PPF) molecular weight, copolymer molecular weight, and ratio of PEG to PPF. Two different cross-linking formulations were also tested, one with a cross-linking monomer and one without. The extent of the cross-linking reaction and the degree of swelling in aqueous solution were determined on copolymer formulations made without a cross-linking monomer. The values of molecular weight between cross-links, Mc ranged from 300 +/- 120 to 1190 +/- 320 as determined from swelling data (n = 3). The equilibrium volume swelling ratios, Q, varied from 1.5 +/- 0.1 to 3.0 +/- 0.1. This ratio was found to increase with increasing PEG content in the copolymer and decrease with increasing PPF molecular weight. The values for complex dynamic elastic moduli magnitudes of E*, ranged from 0.9 +/- 0.2 to 13.1 +/- 1.1 MPa for the formulations with the cross-linking monomer, N-vinyl pyrrolidinone (VP) (n = 3). The ultimate tensile stresses on the formulations made with VP ranged from 0.15 +/- 0.03 to 1.44 +/- 1.06 MPa, and tensile moduli ranged from 1.11 +/- 0.20 to 20.66 +/- 2.42 MPa (n = 5). All of the mechanical properties increased with increasing PPF molecular weight and decreased with increasing PEG content in the copolymer. These data show that the physical properties of p(PF-co-EG) hydrogels can be tailored for specific applications by altering the material composition.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1163/156856298x00073

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 84

Metadata

Authors
Suggs, L. J., Kao, E. Y., Palombo, L. L., Krishnan, R. S., Widmer, M. S., & Mikos, A. G.
Venue
Journal of Biomaterials Science, Polymer Edition
Published
1998-01
Volume
9
Issue
7
Pages
653-666
ISSN
  • 0920-5063 (ISSN-L)
  • 1568-5624
OpenAlex
W2068249055
Cited by
84
References
3
FWCI
3.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Preparation and characterization of poly(propylene fumarate-co-ethylene glycol) hydrogels. https://app.cochat.ai/papers/10.1163/156856298x00073
The paper
Suggs, L. J., Kao, E. Y., Palombo, L. L., Krishnan, R. S., Widmer, M. S., & Mikos, A. G. (1998). Preparation and characterization of poly(propylene fumarate-co-ethylene glycol) hydrogels. Journal of Biomaterials Science, Polymer Edition. https://doi.org/10.1163/156856298x00073

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.