Discrepancies between longitudinal and cross-sectional change in ventilatory function in 12 years of follow-up.
The DOI matches its Crossref record.
Abstract
We compared the age dependence of cross-sectional and longitudinal changes in ventilatory function. FEV1, FVC, and data on chronic respiratory symptoms were obtained from 4,395 adults in a longitudinal survey of normal populations in two different areas in the Netherlands. They participated in up to five surveys at 3-yr intervals between 1972 to 1973 and 1984 to 1985. The ventilatory function in the oldest cohorts is substantially lower than might have been expected from the longitudinal change in the youngest cohorts. This holds for males and females, smokers and nonsmokers, subjects with or without symptoms, and for both survey populations. The robustness of the findings is demonstrated by various data-analytic strategies or omitting one or two of the five surveys from the analysis. Selective loss to follow-up cannot explain the discrepancy. It is concluded that the main differences between our longitudinal and cross-sectional findings may be due to a cohort effect. The implication is that in longitudinal studies of populations at risk, reference equations based on cross-sectional surveys may overestimate longitudinal change and hence lead to underestimating effects of exposure. Similarly, in clinical studies, accelerated decline in ventilatory function may be underrated if it is compared with cross-sectional standards. In older people at any one age the ventilatory function seems to improve in successive birth cohorts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Quanjer, P. H., Stanojevic, S., Cole, T. J., Baur, X., Hall, G. L., Culver, B. H., Enright, P. L., Hankinson, J. L., Ip, M. S. M., Zheng, J., et al. (2012) · European Respiratory Journal · doi:10.1183/09031936.00080312 · Cited by 5,919
Self-citationStocks, J., & Quanjer, P. (1995) · European Respiratory Journal · doi:10.1183/09031936.95.08030492 · Cited by 688
“In addition, they may not fit present day populations due to cohort effects [95–99].”
BackgroundSelf-citationKohansal, R., Martinez-Camblor, P., Agustí, A., Buist, A. S., Mannino, D. M., & Soriano, J. B. (2009) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200901-0047oc · Cited by 654
Swanney, M. P., Ruppel, G., Enright, P. L., Pedersen, O. F., Crapo, R. O., Miller, M. R., Jensen, R. L., Falaschetti, E., Schouten, J. P., Hankinson, J. L., et al. (2008) · Thorax · doi:10.1136/thx.2008.098483 · Cited by 535
Self-citationDecline of FEV1 by age and smoking status: facts, figures, and fallacies
Kerstjens, H. A., Rijcken, B., Schouten, J. P., & Postma, D. S. (1997) · Thorax · doi:10.1136/thx.52.9.820 · Cited by 284
Self-citation
Metadata
- Authors
- van Pelt, W., Borsboom, G. J., Rijcken, B., Schouten, J. P., van Zomeren, B. C., & Quanjer, P. H.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1994-05
- Volume
- 149
- Issue
- 5
- Pages
- 1218-1226
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2100193079
- Cited by
- 82
- References
- 0
- FWCI
- 4.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Discrepancies between longitudinal and cross-sectional change in ventilatory function in 12 years of follow-up. https://app.cochat.ai/papers/10.1164/ajrccm.149.5.8173762
- The paper
- van Pelt, W., Borsboom, G. J., Rijcken, B., Schouten, J. P., van Zomeren, B. C., & Quanjer, P. H. (1994). Discrepancies between longitudinal and cross-sectional change in ventilatory function in 12 years of follow-up. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.149.5.8173762
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.