Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 263

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Cycle length of periodic breathing in patients with and without heart failure.

Hall, M J, Xie, A, Rutherford, R, Ando, S, Floras, J S, Bradley, T D · 1996 · American Journal of Respiratory and Critical Care Medicine

Abstract

Because apnea length during periodic breathing varies according to the preceding increase in ventilation and reduction in PaCO 2, differences in the cycle length of periodic breathing among patients with normal and impaired cardiac function might be explained by the influence of lung-to-carotid body circulatory delay, as reflected by lung-to-ear circulation time (LECT), on hyperpnea length rather than on apnea length. It was therefore hypothesized that circulatory delay is an important determinant of periodic-breathing hyperpnea length but not apnea length. To test this hypothesis, LECT, periodic-breathing cycle length, apnea length, and hyperpnea length were compared in 10 patients with idiopathic central sleep apnea (ICSA), whose cardiac function was normal, as opposed to 10 with Cheyne-Stokes respiration and central sleep apnea (CSR-CSA) in association with congestive heart failure (CHF). As compared with ICSA patients, cycle length was significantly longer in patients with CSR-CSA (37.3 +/- 3.0 s versus 59.0 +/- 4.9 s, p < 0.005). This difference was due to significantly longer hyperpnea length in the CSR-CSA patients (16.7 +/- 2.8 s versus 36.7 +/- 3.4 s, p < 0.001), since apnea length was similar in the two groups. In addition, LECT was longer in the CSR-CSA patients (24.3 +/- 2.0 s versus 10.3 +/- 1.0 s, p < 0.001), and correlated strongly with cycle length (r = 0.88, p < 0.001) and hyperpnea length (r = 0.90, p < 0.001) but not with apnea length. LECT correlated inversely with cardiac output (r = -0.72, p < 0.006), indicating that LECT is a valid measure of circulatory delay. Thus, circulatory delay is an important determinant of hyperpnea length but not of apnea length in patients with ICSA and CSR-CSA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.154.2.8756809

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 263

Metadata

Authors
Hall, M. J., Xie, A., Rutherford, R., Ando, S., Floras, J. S., & Bradley, T. D.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
1996-08
Volume
154
Issue
2
Pages
376-381
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2112704383
Cited by
263
References
19
FWCI
3.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cycle length of periodic breathing in patients with and without heart failure. https://app.cochat.ai/papers/10.1164/ajrccm.154.2.8756809
The paper
Hall, M. J., Xie, A., Rutherford, R., Ando, S., Floras, J. S., & Bradley, T. D. (1996). Cycle length of periodic breathing in patients with and without heart failure. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.154.2.8756809

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.