Cycle length of periodic breathing in patients with and without heart failure.
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Because apnea length during periodic breathing varies according to the preceding increase in ventilation and reduction in PaCO 2, differences in the cycle length of periodic breathing among patients with normal and impaired cardiac function might be explained by the influence of lung-to-carotid body circulatory delay, as reflected by lung-to-ear circulation time (LECT), on hyperpnea length rather than on apnea length. It was therefore hypothesized that circulatory delay is an important determinant of periodic-breathing hyperpnea length but not apnea length. To test this hypothesis, LECT, periodic-breathing cycle length, apnea length, and hyperpnea length were compared in 10 patients with idiopathic central sleep apnea (ICSA), whose cardiac function was normal, as opposed to 10 with Cheyne-Stokes respiration and central sleep apnea (CSR-CSA) in association with congestive heart failure (CHF). As compared with ICSA patients, cycle length was significantly longer in patients with CSR-CSA (37.3 +/- 3.0 s versus 59.0 +/- 4.9 s, p < 0.005). This difference was due to significantly longer hyperpnea length in the CSR-CSA patients (16.7 +/- 2.8 s versus 36.7 +/- 3.4 s, p < 0.001), since apnea length was similar in the two groups. In addition, LECT was longer in the CSR-CSA patients (24.3 +/- 2.0 s versus 10.3 +/- 1.0 s, p < 0.001), and correlated strongly with cycle length (r = 0.88, p < 0.001) and hyperpnea length (r = 0.90, p < 0.001) but not with apnea length. LECT correlated inversely with cardiac output (r = -0.72, p < 0.006), indicating that LECT is a valid measure of circulatory delay. Thus, circulatory delay is an important determinant of hyperpnea length but not of apnea length in patients with ICSA and CSR-CSA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rechtschaffen, A. (1968) · Medical Entomology and Zoology · Cited by 12,675
Factors inducing periodic breathing in humans: a general model
Khoo, M. C., Kronauer, R. E., Strohl, K. P., & Slutsky, A. S. (1982) · Journal of Applied Physiology · doi:10.1152/jappl.1982.53.3.644 · Cited by 579
Naughton, M. T., Rahman, M. A., Hara, K., Floras, J. S., & Bradley, T. D. (1995) · Circulation · doi:10.1161/01.cir.91.6.1725 · Cited by 466
Self-citationNaughton, M., Benard, D., Tam, A., Rutherford, R., & Bradley, T. D. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/148.2.330 · Cited by 393
Self-citationValidation of respiratory inductive plethysmography using different calibration procedures.
Chadha, T. S., Watson, H., Birch, S., Jenouri, G., Schneider, A. W., Cohn, M. A., & Sackner, M. A. (1982) · PubMed · doi:10.1164/arrd.1982.125.6.644 · Cited by 334
Interaction of hyperventilation and arousal in the pathogenesis of idiopathic central sleep apnea.
Xie, A., Wong, B., Phillipson, E. A., Slutsky, A. S., & Bradley, T. D. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.2.8049835 · Cited by 212
Self-citationBasic Oscillating Mechanism of Cheyne-Stokes Breathing
Guyton, A. C., Crowell, J. W., & Moore, J. W. (1956) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1956.187.2.395 · Cited by 190
Pathogenesis of Cheyne-Stokes Respiration in Patients With Congestive Heart Failure
Hanly, P., Zuberi, N., & Gray, R. (1993) · Chest · doi:10.1378/chest.104.4.1079 · Cited by 175
Hypocapnia and increased ventilatory responsiveness in patients with idiopathic central sleep apnea.
Xie, A., Rutherford, R., Rankin, F., Wong, B., & Bradley, T. D. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.152.6.8520761 · Cited by 172
Self-citationEffect of Nasal Continuous Positive Airway Pressure on Sleep Apnea in Congestive Heart Failure
Takasaki, Y., Orr, D., Popkin, J., Rutherford, R., Liu, P., & Bradley, T. D. (1989) · American Review of Respiratory Disease · doi:10.1164/ajrccm/140.6.1578 · Cited by 159
Self-citation
Cited by
Berry, R. B., Budhiraja, R., Gottlieb, D. J., Gozal, D., Iber, C., Kapur, V. K., Marcus, C. L., Mehra, R., Parthasarathy, S., Quan, S. F., et al. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2172 · Cited by 5,302
Sleep Apnea and Cardiovascular Disease
LEUNG, R. S. T., & DOUGLAS BRADLEY, T. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.12.2107045 · Cited by 649
Eckert, D. J., Jordan, A. S., Merchia, P., & Malhotra, A. (2007) · Chest · doi:10.1378/chest.06.2287 · Cited by 559
Sleep Apnea and Heart Failure: Part I: Obstructive Sleep Apnea
Bradley, T. D., & Floras, J. S. (2003) · Circulation · doi:10.1161/01.cir.0000061757.12581.15 · Cited by 554
Self-citationSleep Apnea and Heart Failure: Part II: Central Sleep Apnea
Bradley, T. D., & Floras, J. S. (2003) · Circulation · doi:10.1161/01.cir.0000061758.05044.64 · Cited by 517
Self-citationA Mechanism of Central Sleep Apnea in Patients with Heart Failure
Javaheri, S. (1999) · New England Journal of Medicine · doi:10.1056/nejm199909233411304 · Cited by 498
Classification of Sleep Disorders
Thorpy, M. J. (2012) · Neurotherapeutics · doi:10.1007/s13311-012-0145-6 · Cited by 444
Role of nocturnal rostral fluid shift in the pathogenesis of obstructive and central sleep apnoea
White, L. H., & Bradley, T. D. (2013) · The Journal of Physiology · doi:10.1113/jphysiol.2012.245159 · Cited by 348
Self-citationEffect of Ventilator Mode on Sleep Quality in Critically Ill Patients
Parthasarathy, S., & Tobin, M. J. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200209-999oc · Cited by 324
Nocturnal hypoxaemia is associated with increased mortality in stable heart failure patients
Oldenburg, O., Wellmann, B., Buchholz, A., Bitter, T., Fox, H., Thiem, U., Horstkotte, D., & Wegscheider, K. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv624 · Cited by 311
SOLIN, P., ROEBUCK, T., JOHNS, D. P., HAYDN WALTERS, E., & NAUGHTON, M. T. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.6.2002024 · Cited by 290
Quantifying the ventilatory control contribution to sleep apnoea using polysomnography
Terrill, P. I., Edwards, B. A., Nemati, S., Butler, J. P., Owens, R. L., Eckert, D. J., White, D. P., Malhotra, A., Wellman, A., & Sands, S. A. (2015) · European Respiratory Journal · doi:10.1183/09031936.00062914 · Cited by 289
“The typical baseline value for the T n of ∼ 38 s in our study (figs 5c and 6c, and online supplementary table S1) closely matches the ∼ 37-s T n seen in patients with idiopathic central sleep apnoea [30].”
InfluentialSinha, A.-M., Skobel, E. C., Breithardt, O.-A., Norra, C., Markus, K. U., Breuer, C., Hanrath, P., & Stellbrink, C. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.03.040 · Cited by 247
Sleep Apnea and Cardiovascular Disease: An Enigmatic Risk Factor
Floras, J. S. (2018) · Circulation Research · doi:10.1161/circresaha.118.310783 · Cited by 209
“At the bedside, the observant clinician can estimate cardiac output by timing the duration of hyperpnea.(216) As with OSA,(27,30) the majority of HFrEF patients with CSA does not profess sleepiness(38,39,215); their average ESS scores are also lower than those with HFrEF and OSA.”
BackgroundInfluentialSelf-citationJavaheri, S., & Dempsey, J. A. (2013) · Comprehensive Physiology · doi:10.1002/cphy.c110057 · Cited by 205
Eckert, D. J., Malhotra, A., & Jordan, A. S. (2009) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2008.02.003 · Cited by 173
“Adapted with There is a substantial range in the prevalence between the various forms of CSA.”
BackgroundInfluentialEntrainment of Blood Pressure and Heart Rate Oscillations by Periodic Breathing
LORENZI-FILHO, G., DAJANI, H. R., LEUNG, R. S. T., FLORAS, J. S., & BRADLEY, T. D. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.4.9806081 · Cited by 105
Self-citationSleep Disordered Breathing in Group 1 Pulmonary Arterial Hypertension
Minic, M., Granton, J. T., & Ryan, C. M. (2014) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.3528 · Cited by 92
“The cycle length of our cohort, although prolonged, was of shorter duration than that of patients with heart failure (59 seconds), 21 but similar in duration to that of patients with heart failure and preserved ejection fraction.”
Sériès, F., Kimoff, R. J., Morrison, D., Leblanc, M. H., Smilovitch, M., Howlett, J., Logan, A. G., Floras, J. S., & Bradley, T. D. (2005) · Chest · doi:10.1378/chest.127.5.1507 · Cited by 83
Self-citationPathophysiologic and therapeutic implicationsof sleep apnea in congestive heart failure
Bradley, T. D., & Floras, J. S. (1996) · Journal of Cardiac Failure · doi:10.1016/s1071-9164(96)80045-5 · Cited by 78
Self-citation
Metadata
- Authors
- Hall, M. J., Xie, A., Rutherford, R., Ando, S., Floras, J. S., & Bradley, T. D.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-08
- Volume
- 154
- Issue
- 2
- Pages
- 376-381
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2112704383
- Cited by
- 263
- References
- 19
- FWCI
- 3.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.