Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 301

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Detection of Flow Limitation with a Nasal Cannula/ Pressure Transducer System

HOSSELET, JEAN-JACQUES, NORMAN, ROBERT G., AYAPPA, INDU, RAPOPORT, DAVID M.·1998·American Journal of Respiratory and Critical Care Medicine

Abstract

We previously showed that upper airway resistance can be inferred from the inspiratory flow contour during continuous positive airway pressure (CPAP) titration in obstructive sleep apnea syndrome (OSAS). The present study examines whether similar information can be obtained from inspiratory flow measured by a nasal cannula/pressure transducer. Ten symptomatic patients (snoring, upper airway resistance syndrome [UARS], or OSAS) and four asymptomatic subjects underwent nocturnal polysomnography (NPSG) with monitoring of flow (nasal cannula) and respiratory driving pressure (esophageal or supraglottic catheter). For each breath the inspiratory flow signal was classified as normal, flattened, or intermediate by custom software. "Resistance" was calculated from peak inspiratory flow and pressure, and normalized to the resistance during quiet wakefulness. Resistance in all stages of sleep was increased for breaths with flattened (387 +/- 188%) or intermediate (292 +/- 163%) flow contour. In combination with apnea-hypopnea index (AHI), identification of "respiratory events," consisting of consecutive breaths with a flattened contour, allowed differentiation of symptomatic from asymptomatic subjects. Our data show that development of a plateau on the inspiratory flow signal from a nasal cannula identifies increased upper airway resistance and the presence of flow limitation. In patients with symptoms of excessive daytime somnolence and low AHI this may help diagnose the UARS and separate it from nonrespiratory causes of sleep fragmentation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.157.5.9708008

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 301

Metadata

Authors
HOSSELET, J.-J., NORMAN, R. G., AYAPPA, I., & RAPOPORT, D. M.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
1998-05-01
Volume
157
Issue
5
Pages
1461-1467
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2122295507
Cited by
301
References
11
FWCI
8.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection of Flow Limitation with a Nasal Cannula/ Pressure Transducer System. https://app.cochat.ai/papers/10.1164/ajrccm.157.5.9708008
The paper
HOSSELET, J.-J., NORMAN, R. G., AYAPPA, I., & RAPOPORT, D. M. (1998). Detection of Flow Limitation with a Nasal Cannula/ Pressure Transducer System. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.157.5.9708008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.