Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 233

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A Lung Computed Tomographic Assessment of Positive End-Expiratory Pressure–induced Lung Overdistension

VIEIRA, SILVIA R. R., PUYBASSET, LOUIS, RICHECOEUR, JACK, LU, QIN, CLUZEL, PHILIPPE, GUSMAN, PABLO B., CORIAT, PIERRE, ROUBY, JEAN-JACQUES·1998·American Journal of Respiratory and Critical Care Medicine

Abstract

The aim of this study was to assess positive end-expiratory pressure (PEEP)-induced lung overdistension and alveolar recruitment in six patients with acute lung injury (ALI) using a computed tomographic (CT) scan method. Lung overdistension was first determined in six healthy volunteers in whom CT sections were obtained at FRC and at TLC with a positive airway pressure of 30 cm H2O. In patients, lung volumes were quantified by the analysis of the frequency distribution of CT numbers on the entire lung at zero end-expiratory pressure (ZEEP) and PEEP. In healthy volunteers at FRC, the distribution of the density histograms was monophasic with a peak at -791 +/- 12 Hounsfield units (HU). The lowest CT number observed was -912 HU. At TLC, lung volume increased by 79 +/- 35% and the peak CT number decreased to -886 +/- 26 HU. More than 70% of the increase in lung volume was located below -900 HU, suggesting that this value can be considered as the threshold separating normal aeration from overdistension. In patients with ALI, at ZEEP the distribution of density histograms was either monophasic (n = 3) or biphasic (n = 3). The mean CT number was -319 +/- 34 HU. At PEEP 13 +/- 3 cm H2O, lung volume increased by 47 +/- 19% whereas mean CT number decreased to -538 +/- 171 HU. PEEP induced a mean alveolar recruitment of 320 +/- 160 ml and a mean lung overdistension of 238 +/- 320 ml. In conclusion, overdistended lung parenchyma of healthy volunteers is characterized by a CT number below -900 HU. This threshold can be used in patients with ALI for differentiating PEEP-induced alveolar recruitment from lung overdistension.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.158.5.9802101

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 233

Metadata

Authors
VIEIRA, S. R. R., PUYBASSET, L., RICHECOEUR, J., LU, Q., CLUZEL, P., GUSMAN, P. B., CORIAT, P., & ROUBY, J.-J.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
1998-11-01
Volume
158
Issue
5
Pages
1571-1577
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2154199254
Cited by
233
References
1
FWCI
8.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Lung Computed Tomographic Assessment of Positive End-Expiratory Pressure–induced Lung Overdistension. https://app.cochat.ai/papers/10.1164/ajrccm.158.5.9802101
The paper
VIEIRA, S. R. R., PUYBASSET, L., RICHECOEUR, J., LU, Q., CLUZEL, P., GUSMAN, P. B., CORIAT, P., & ROUBY, J.-J. (1998). A Lung Computed Tomographic Assessment of Positive End-Expiratory Pressure–induced Lung Overdistension. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.158.5.9802101

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.