CoChat

A Simple Automated Method for Measuring Pressure–Volume Curves during Mechanical Ventilation

LU, QIN, VIEIRA, SILVIA R. R., RICHECOEUR, JACK, PUYBASSET, LOUIS, KALFON, PIERRE, CORIAT, PIERRE, ROUBY, JEAN-JACQUES · 1999 · American Journal of Respiratory and Critical Care Medicine
Cited by 169

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Measurement of respiratory compliance is advocated for assessing the severity of acute respiratory failure (ARF). Recently, the administration of an automated constant flow of 15 L/min was proposed as a method easier to implement at the bedside than supersyringe or inspiratory occlusions methods. However, pressure-volume (P-V) curves were shifted to the right because of the resistive properties of the respiratory system. The aim of this study was to compare the P-V curves obtained using two constant flows-3 and 9 L/min-during volume-controlled mechanical ventilation with those obtained with the supersyringe and the inspiratory occlusions methods. Fourteen paralyzed patients with ARF were studied. The supersyringe and the inspiratory occlusions methods were performed according to usual recommendations. The new automated method was performed during volume-controlled mechanical ventilation by setting the inspiratory:expiratory ratio at 80%, the respiratory frequency at 5 breaths/min, and the tidal volume at 500 or 1,500 ml. These peculiar ventilatory settings were equivalent to administering a constant flow of 3 or 9 L/min during a 9.6-s inspiration. Esophageal and airway pressures were recorded. P-V curves obtained by the 3-L/min constant-flow method were identical to those obtained by the reference methods, whereas the P-V curve obtained by the 9-L/min constant flow was slightly shifted to the right. The slopes of the P-V curves and the lower inflection points were not different between all methods, indicating that the resistive component induced by administering a constant flow equal to or less than 9 L/min is not of clinical relevance. Because the 3-L/min constant-flow method is not artifacted by the resistive properties of the respiratory system and does not require any other equipment than a ventilator, it is an easy-to-implement, inexpensive, safe, and reliable method for measuring the thoracopulmonary P-V curve at the bedside.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.159.1.9802082

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 169

Metadata

Authors
LU, Q., VIEIRA, S. R. R., RICHECOEUR, J., PUYBASSET, L., KALFON, P., CORIAT, P., & ROUBY, J.-J.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
1999-01-01
Volume
159
Issue
1
Pages
275-282
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2085938647
Cited by
169
References
2
FWCI
13.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Simple Automated Method for Measuring Pressure–Volume Curves during Mechanical Ventilation. https://app.cochat.ai/papers/10.1164/ajrccm.159.1.9802082
The paper
LU, Q., VIEIRA, S. R. R., RICHECOEUR, J., PUYBASSET, L., KALFON, P., CORIAT, P., & ROUBY, J.-J. (1999). A Simple Automated Method for Measuring Pressure–Volume Curves during Mechanical Ventilation. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.159.1.9802082

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.