CoChat

Changes in the Work of Breathing Induced by Tracheotomy in Ventilator-dependent Patients

DIEHL, JEAN-LUC, EL ATROUS, SOUHEIL, TOUCHARD, DOMINIQUE, LEMAIRE, FRANÇOIS, BROCHARD, LAURENT · 1999 · American Journal of Respiratory and Critical Care Medicine
Cited by 330

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

Tracheotomy is widely performed on ventilator-dependent patients, but its effects on respiratory mechanics have not been studied. We measured the work of breathing (WOB) in eight patients before and after tracheotomy during breathing at three identical levels of pressure support (PS): baseline level (PS-B), PS + 5 cm H2O (PS+5), and PS - 5 cm H2O (PS-5). After the procedure, we also compared the resistive work induced by the patients' endotracheal tubes (ETTs) and by a new tracheotomy cannula in an in vitro bench study. A significant reduction in the WOB was observed after tracheotomy for PS-B (from 0.9 +/- 0.4 to 0.4 +/- 0.2 J/L, p < 0.05), and for PS-5 (1.4 +/- 0.6 to 0.6 +/- 0.3 J/L, p < 0.05), with a near-significant reduction for PS+5 (0.5 +/- 0.5 to 0.2 +/- 0.1 J/L, p = 0.05). A significant reduction was also observed in the pressure-time index of the respiratory muscles (181 +/- 92 to 80 +/- 56 cm H2O. s/min for PS-B, p < 0.05). Resistive and elastic work computed from transpulmonary pressure measurements decreased significantly at PS-B and PS-5. A significant reduction in occlusion pressure and intrinsic positive end-expiratory pressure (PEEP) was also observed for all conditions, with no significant change in breathing pattern. Three patients had ineffective breathing efforts before tracheotomy, and all had improved synchrony with the ventilator after the procedure. In vitro measurements made with ETTs removed from the patients, with new ETTs, and with the tracheotomy cannula showed that the cannula reduced the resistive work induced by the artificial airway. Part of these results was explained by a slight, subtle reduction of the inner diameter of used ETTs. We conclude that tracheotomy can substantially reduce the mechanical workload of ventilator-dependent patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.159.2.9707046

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

Metadata

Authors
DIEHL, J.-L., EL ATROUS, S., TOUCHARD, D., LEMAIRE, F., & BROCHARD, L.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
1999-02-01
Volume
159
Issue
2
Pages
383-388
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2147677195
Cited by
330
References
19
FWCI
8.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.