CoChat

Progressive Mechanical Ventilatory Constraints with Aging

DeLOREY, DARREN S., BABB, TONY G. · 1999 · American Journal of Respiratory and Critical Care Medicine
Cited by 93

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

To investigate the progressive nature of mechanical ventilatory constraints with aging, we studied 20 young (age 39 +/- 3 yr), 14 senior (70 +/- 2 yr), and 11 elderly (88 +/- 2 yr) men and women during exercise. All subjects had normal pulmonary function and performed graded cycle ergometry to exhaustion. Minute ventilation (V E), lung volume, and expiratory airflow limitation (EAFL) were measured during each 1-min increment in work rate. Data were analyzed by two-way analysis of variance (ANOVA; age x gender) at rest, ventilatory threshold (VTh), and peak exercise. If an interaction was present, each gender was analyzed with a one-way ANOVA. Aging resulted in an increased V E for a given submaximal work rate, although V E during peak exercise was lowest in the elderly group (p < 0.01). End-expiratory lung volume (EELV, % of TLC) in men increased progressively with age and all groups were different at VTh (p < 0.01) and peak exercise (p < 0.01). In women, EELV (% of TLC) also increased with aging, the senior and elderly subjects had a greater EELV at VTh (p < 0.01) and peak exercise (p < 0.01) than the young group. Additionally, the normal decrease in EELV during the early stages of exercise was not observed in elderly subjects. End-inspiratory lung volume (EILV) also progressively increased with aging; senior and elderly subjects had a higher EILV at rest (p < 0.05), VTh (p < 0.01), and peak exercise (p < 0.01) than young subjects. EAFL (% of VT) increased with aging; elderly subjects experienced greater EAFL at rest (p < 0.05), VTh (p < 0.01), and peak exercise (p < 0.01) than both young and senior subjects. We conclude that mechanical ventilatory constraints are progressive with aging, elderly subjects demonstrating marked mechanical ventilatory constraints during exercise. The impact of these constraints on exercise tolerance cannot be determined from this investigation and remains unclear.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.160.1.9807045

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 93

Metadata

Authors
DeLOREY, D. S., & BABB, T. G.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
1999-07-01
Volume
160
Issue
1
Pages
169-177
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2080171195
Cited by
93
References
4
FWCI
2.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.