Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 204

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

An Objective Analysis of the Pressure-Volume Curve in the Acute Respiratory Distress Syndrome

SCOTT HARRIS, R., HESS, DEAN R., VENEGAS, JOSÉ G. · 2000 · American Journal of Respiratory and Critical Care Medicine

Abstract

To assess the interobserver and intraobserver variability in the clinical evaluation of the quasi-static pressure-volume (P-V) curve, we analyzed 24 sets of inflation and deflation P-V curves obtained from patients with ARDS. We used a recently described sigmoidal equation to curve-fit the P-V data sets and objectively define the point of maximum compliance increase of the inflation limb (P(mci, i)) and the true inflection point of the deflation limb (P(inf,d)). These points were compared with graphic determinations of lower Pflex by seven clinicians. The graphic and curve-fitting methods were also compared for their ability to reproduce the same parameter value in data sets with reduced number of data points. The sigmoidal equation fit the P-V data with great accuracy (R(2) = 0.9992). The average of Pflex determinations was found to be correlated with P(mci,i) (R = 0.89) and P(inf,d) (R = 0.76). Individual determinations of Pflex were less correlated with the corresponding objective parameters (R = 0.67 and 0.62, respectively). Pflex + 2 cm H(2)O was a more accurate estimator of P(inf,d) (2 SD = +/-6.05 cm H(2)O) than Pflex was of P(mci,i) (2 SD = +/-8.02 cm H(2)O). There was significant interobserver variability in Pflex, with a maximum difference of 11 cm H(2)O for the same patient (SD = 1.9 cm H(2)O). Clinicians had difficulty reproducing Pflex in smaller data sets with differences as great as 17 cm H(2)O (SD = 2.8 cm H(2)O). In contrast, the curve-fitting method reproduced P(mci,i) with great accuracy in reduced data sets (maximum difference of 1.5 cm H(2)O and SD = 0.3 cm H(2)O). We conclude that Pflex rarely coincided with the point of maximum compliance increase defined by a sigmoid curve-fit with large differences in Pflex seen both among and within observers. Calculating objective parameters such as P(mci,i) or P(inf,d) from curve-fitted P-V data can minimize this large variability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.161.2.9901061

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 204

Metadata

Authors
SCOTT HARRIS, R., HESS, D. R., & VENEGAS, J. G.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2000-02-01
Volume
161
Issue
2
Pages
432-439
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2148025574
Cited by
204
References
3
FWCI
13.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Objective Analysis of the Pressure-Volume Curve in the Acute Respiratory Distress Syndrome. https://app.cochat.ai/papers/10.1164/ajrccm.161.2.9901061
The paper
SCOTT HARRIS, R., HESS, D. R., & VENEGAS, J. G. (2000). An Objective Analysis of the Pressure-Volume Curve in the Acute Respiratory Distress Syndrome. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.161.2.9901061

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.