CoChat

Accuracy of an Unattended Home CPAP Titration in the Treatment of Obstructive Sleep Apnea

SÉRIÈS, F. · 2000 · American Journal of Respiratory and Critical Care Medicine
Cited by 81

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Treatment of sleep apnea-hypopnea syndrome (SAHS) by fixed continuous positive airway pressure (CPAP) requires an in-laboratory titration procedure to determine the effective pressure level (Peff ). We recently reported that one auto-CPAP machine can be used without titration study allowing Peff determination. The aim of this study was to evaluate the accuracy of an auto CPAP trial at home. A 1- or 2-wk automatic CPAP trial was done at home in 40 patients by estimating the reference pressure (Pref ) to be set and a Pref + 3 cm H(2)O/-4 cm H(2)O pressure interval. Peff was then determined according to the percentage of CPAP time that was spent </= Pref. This Peff value was set on a fixed CPAP machine for two additional weeks and a control sleep study was done. The pressure setting on fixed CPAP had to be increased by 1 +/- 1 cm H(2)O (mean +/- SD) above estimated Pref. Sleep improved with fixed CPAP, with a normalization of the apnea + hypopnea index (AHI) in 38 of 40 and resumption of diurnal hypersomnolence. CPAP compliance remained excellent (CPAP use: 6.1 +/- 1.7 h/ night) after 6.5 +/- 2.8 mo of CPAP treatment. These results indicate that auto-CPAP therapy represents a new useful and accurate way to identify conventional CPAP setting outside hospital and sleep laboratories.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.162.1.9908023

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 81

Metadata

Authors
SÉRIÈS, F.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2000-07-01
Volume
162
Issue
1
Pages
94-97
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2134787757
Cited by
81
References
1
FWCI
3.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.