The DOI matches its Crossref record.
FEV 6 Is an Acceptable Surrogate for FVC in the Spirometric Diagnosis of Airway Obstruction and Restriction
Abstract
We analyzed the FEV(1)/FEV(6) and FEV(1)/FVC results of 502 consecutive patients in the spirometric diagnosis of airway obstruction. We also examined the agreement between FEV(6) and FVC in the spirometric diagnosis of restriction. Technically acceptable test results were obtained from 337 subjects (67%). The sensitivity of FEV(1)/FEV(6) for diagnosing airway obstruction as defined by FEV(1)/ FVC was 95.0%; the specificity was 97.4%. When interpretations differed, the measured values were all close to the lower limits of the reference ranges. When analysis included +/- 100-ml variability in FEV(1) and FEV(6), the sensitivity increased to 99.5% and the specificity to 100%. The reproducibility of FEV(6) was superior to that of FVC. These results suggest that FEV(6) is an accurate, reliable alternative to FVC for diagnosing airway obstruction and that FEV(6) is reasonably comparable to FVC for the spirometric diagnosis of restriction. FEV(6) is more reproducible and less physically demanding for patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Miller, M. R., Hankinson, J., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Crapo, R., Enright, P., van der Grinten, C. P. M., Gustafsson, P., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00034805 · Cited by 15,627
Self-citationQuanjer, P. H., Stanojevic, S., Cole, T. J., Baur, X., Hall, G. L., Culver, B. H., Enright, P. L., Hankinson, J. L., Ip, M. S. M., Zheng, J., et al. (2012) · European Respiratory Journal · doi:10.1183/09031936.00080312 · Cited by 5,919
Graham, B. L., Steenbruggen, I., Miller, M. R., Barjaktarevic, I. Z., Cooper, B. G., Hall, G. L., Hallstrand, T. S., Kaminsky, D. A., McCarthy, K., McCormack, M. C., et al. (2019) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201908-1590st · Cited by 4,305
Self-citationGeneral considerations for lung function testing
Miller, M. R., Crapo, R., Hankinson, J., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Enright, P., Grinten, C. P. M. V. D., Gustafsson, P., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00034505 · Cited by 2,026
Self-citationBurden and clinical features of chronic obstructive pulmonary disease (COPD)
Pauwels, R. A., & Rabe, K. F. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16855-4 · Cited by 1,004
Metadata
- Authors
- SWANNEY, M. P., JENSEN, R. L., CRICHTON, D. A., BECKERT, L. E., CARDNO, L. A., & CRAPO, R. O.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-09-01
- Volume
- 162
- Issue
- 3
- Pages
- 917-919
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2162513262
- Cited by
- 196
- References
- 0
- FWCI
- 5.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: FEV 6 Is an Acceptable Surrogate for FVC in the Spirometric Diagnosis of Airway Obstruction and Restriction. https://app.cochat.ai/papers/10.1164/ajrccm.162.3.9907115
- The paper
- SWANNEY, M. P., JENSEN, R. L., CRICHTON, D. A., BECKERT, L. E., CARDNO, L. A., & CRAPO, R. O. (2000). FEV 6 Is an Acceptable Surrogate for FVC in the Spirometric Diagnosis of Airway Obstruction and Restriction. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.162.3.9907115
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.