Electrical Activity of the Diaphragm during Pressure Support Ventilation in Acute Respiratory Failure
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
We compared crural diaphragm electrical activity (EAdi) with transdiaphragmatic pressure (Pdi) during varying levels of pressure support ventilation (PS) in 13 intubated patients. With changing PS, we found no evidence for changes in neuromechanical coupling of the diaphragm. From lowest to highest PS (2 cm H(2)O +/- 4 to 20 cm H(2)O +/- 7), tidal volume increased from 430 ml +/- 180 to 527 ml +/- 180 (p < 0.001). The inspiratory volume calculated during the period when EAdi increased to its peak did not change from 276 +/- 147 to 277 +/- 162 ml, p = 0.976. Respiratory rate decreased from 23.9 (+/- 7) to 21.3 (+/- 7) breaths/min (p = 0.015). EAdi and Pdi decreased proportionally by adding PS (r = 0.84 and r = 0.90, for mean and peak values, respectively). Mean and peak EAdi decreased (p < 0.001) by 33 +/- 21% (mean +/- SD) and 37 +/- 23% with the addition of 10 cm H(2)O of PS, similar to the decrease in the mean and peak Pdi (p < 0.001) observed (34 +/- 36 and 35 +/- 23%). We also found that ventilator assist continued during the diaphragm deactivation period, a phenomenon that was further exaggerated at higher PS levels. We conclude that EAdi is a valid measurement of neural drive to the diaphragm in acute respiratory failure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The heat of shortening and the dynamic constants of muscle
Hill, A. V. (1938) · Proceedings of the Royal Society of London. Series B - Biological Sciences · doi:10.1098/rspb.1938.0050 · Cited by 3,669
A simple method for assessing the validity of the esophageal balloon technique.
Baydur, A., BEHRAKIS, P. K., Zin, W. A., Jaeger, M., & Milic‐Emili, J. (1982) · PubMed · doi:10.1164/arrd.1982.126.5.788 · Cited by 1,076
Neural control of mechanical ventilation in respiratory failure
Sinderby, C., Navalesi, P., Beck, J., Skrobik, Y., Comtois, N., Friberg, S., Gottfried, S. B., & Lindström, L. (1999) · Nature Medicine · doi:10.1038/71012 · Cited by 636
Self-citationComparison of assisted ventilator modes on triggering, patient effort, and dyspnea.
Leung, P., Jubran, A., & Tobin, M. J. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.6.9196100 · Cited by 420
Respiratory muscle fatigue during cardiogenic shock
Aubier, M., Trippenbach, T., & Roussos, C. (1981) · Journal of Applied Physiology · doi:10.1152/jappl.1981.51.2.499 · Cited by 349
Voluntary activation of the human diaphragm in health and disease
Sinderby, C., Beck, J., Spahija, J., Weinberg, J., & Grassino, A. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.6.2146 · Cited by 235
Self-citationLessard, M. R., Lofaso, F., & Brochard, L. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.151.2.7842221 · Cited by 204
Diaphragm Activation during Exercise in Chronic Obstructive Pulmonary Disease
SINDERBY, C., SPAHIJA, J., BECK, J., KAMINSKI, D., YAN, S., COMTOIS, N., & SLIWINSKI, P. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.7.2007033 · Cited by 201
Self-citationNava, S., Ambrosino, N., Rubini, F., Fracchia, C., Rampulla, C., Torri, G., & Calderini, E. (1993) · Chest · doi:10.1378/chest.103.1.143 · Cited by 193
Three-dimensional reconstruction of the in vivo human diaphragm shape at different lung volumes
Gauthier, A. P., Verbanck, S., Estenne, M., Segebarth, C., Macklem, P. T., & Paiva, M. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.76.2.495 · Cited by 193
Cited by
ATS/ERS Statement on Respiratory Muscle Testing
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.166.4.518 · Cited by 2,841
Patient-ventilator asynchrony during assisted mechanical ventilation
Thille, A. W., Rodriguez, P., Cabello, B., Lellouche, F., & Brochard, L. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0301-8 · Cited by 930
Mechanical Ventilation–induced Diaphragm Atrophy Strongly Impacts Clinical Outcomes
Goligher, E. C., Dres, M., Fan, E., Rubenfeld, G. D., Scales, D. C., Herridge, M. S., Vorona, S., Sklar, M. C., Rittayamai, N., Lanys, A., et al. (2018) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201703-0536oc · Cited by 813
Esophageal and transpulmonary pressure in the clinical setting: meaning, usefulness and perspectives
Mauri, T., Yoshida, T., Bellani, G., Goligher, E. C., Carteaux, G., Rittayamai, N., Mojoli, F., Chiumello, D., Piquilloud, L., Grasso, S., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4400-x · Cited by 554
Asynchronies during mechanical ventilation are associated with mortality
Blanch, L., Villagra, A., Sales, B., Montanya, J., Lucangelo, U., Luján, M., García-Esquirol, O., Chacón, E., Estruga, A., Oliva, J. C., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3692-6 · Cited by 539
Mechanical Ventilation: State of the Art
Pham, T., Brochard, L. J., & Slutsky, A. S. (2017) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2017.05.004 · Cited by 377
Other approaches to open-lung ventilation: Airway pressure release ventilation
Habashi, N. M. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000155920.11893.37 · Cited by 309
Thille, A. W., Cabello, B., Galia, F., Lyazidi, A., & Brochard, L. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1121-9 · Cited by 288
Respiratory Drive in Critically Ill Patients. Pathophysiology and Clinical Implications
Vaporidi, K., Akoumianaki, E., Telias, I., Goligher, E. C., Brochard, L., & Georgopoulos, D. (2020) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201903-0596so · Cited by 267
Bertoni, M., Telias, I., Urner, M., Long, M., Del Sorbo, L., Fan, E., Sinderby, C., Beck, J., Liu, L., Qiu, H., et al. (2019) · Critical Care · doi:10.1186/s13054-019-2617-0 · Cited by 262
Self-citationSpahija, J., de Marchie, M., Albert, M., Bellemare, P., Delisle, S., Beck, J., & Sinderby, C. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181cb0d7b · Cited by 211
“Our finding that increasing the PSV level did not significantly alter the observed trigger delays is consistent with previous studies, which likewise used crural EAdi to assess patient-ventilator synchrony (13, 17).”
BackgroundResultSelf-citationEstimation of Patient’s Inspiratory Effort From the Electrical Activity of the Diaphragm*
Bellani, G., Mauri, T., Coppadoro, A., Grasselli, G., Patroniti, N., Spadaro, S., Sala, V., Foti, G., & Pesenti, A. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31827caba0 · Cited by 189
Contrasting pressure-support ventilation and helium–oxygen during exercise in severe COPD
Hussain, O., Collins, E. G., Adiguzel, N., Langbein, W. E., Tobin, M. J., & Laghi, F. (2011) · Respiratory Medicine · doi:10.1016/j.rmed.2010.08.008 · Cited by 22
Metadata
- Authors
- BECK, J., GOTTFRIED, S. B., NAVALESI, P., SKROBIK, Y., COMTOIS, N., ROSSINI, M., & SINDERBY, C.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-08-01
- Volume
- 164
- Issue
- 3
- Pages
- 419-424
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2112534156
- Cited by
- 203
- References
- 20
- FWCI
- 4.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.