Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 262

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

A novel non-invasive method to detect excessively high respiratory effort and dynamic transpulmonary driving pressure during mechanical ventilation

Open access
Bertoni, Michele, Telias, Irene, Urner, Martin, Long, Michael, Del Sorbo, Lorenzo, Fan, Eddy, Sinderby, Christer, Beck, Jennifer, Liu, Ling, Qiu, Haibo, Wong, Jenna, Slutsky, Arthur S., Ferguson, Niall D., Brochard, Laurent J., Goligher, Ewan C.·2019·Critical Care

Abstract

Background: Excessive respiratory muscle effort during mechanical ventilation may cause patient self-inflicted lung injury and load-induced diaphragm myotrauma, but there are no non-invasive methods to reliably detect elevated transpulmonary driving pressure and elevated respiratory muscle effort during assisted ventilation. We hypothesized that the swing in airway pressure generated by respiratory muscle effort under assisted ventilation when the airway is briefly occluded (Δ Pocc) could be used as a highly feasible non-invasive technique to screen for these conditions. Methods: Respiratory muscle pressure (Pmus), dynamic transpulmonary driving pressure (Δ PL,dyn, the difference between peak and end-expiratory transpulmonary pressure), and Δ Pocc were measured daily in mechanically ventilated patients in two ICUs in Toronto, Canada. A conversion factor to predict Δ PL,dyn and Pmus from Δ Pocc was derived and validated using cross-validation. External validity was assessed in an independent cohort (Nanjing, China). Results: Fifty-two daily recordings were collected in 16 patients. In this sample, Pmus and Δ PL were frequently excessively high: Pmus exceeded 10 cm H 2 O on 84% of study days and Δ PL,dyn exceeded 15 cm H 2 O on 53% of study days. Δ Pocc measurements accurately detected Pmus > 10 cm H 2 O (AUROC 0.92, 95% CI 0.83–0.97) and Δ PL,dyn > 15 cm H 2 O (AUROC 0.93, 95% CI 0.86–0.99). In the external validation cohort (n = 12), estimating Pmus and Δ PL,dyn from Δ Pocc measurements detected excessively high Pmus and Δ PL,dyn with similar accuracy (AUROC ≥ 0.94). Conclusions: Measuring Δ Pocc enables accurate non-invasive detection of elevated respiratory muscle pressure and transpulmonary driving pressure. Excessive respiratory effort and transpulmonary driving pressure may be frequent in spontaneously breathing ventilated patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s13054-019-2617-0

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 262

Metadata

Authors
Bertoni, M., Telias, I., Urner, M., Long, M., Del Sorbo, L., Fan, E., Sinderby, C., Beck, J., Liu, L., Qiu, H., Wong, J., Slutsky, A. S., Ferguson, N. D., Brochard, L. J., & Goligher, E. C.
Venue
Critical Care
Published
2019-11-06
Volume
23
Issue
1
Pages
346-346
ISSN
1364-8535 (ISSN-L)
OpenAlex
W2985798828
Cited by
262
References
24
FWCI
12.19
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A novel non-invasive method to detect excessively high respiratory effort and dynamic transpulmonary driving pressure during mechanical ventilation. https://app.cochat.ai/papers/10.1186/s13054-019-2617-0
The paper
Bertoni, M., Telias, I., Urner, M., Long, M., Del Sorbo, L., Fan, E., Sinderby, C., Beck, J., Liu, L., Qiu, H., Wong, J., Slutsky, A. S., Ferguson, N. D., Brochard, L. J., & Goligher, E. C. (2019). A novel non-invasive method to detect excessively high respiratory effort and dynamic transpulmonary driving pressure during mechanical ventilation. Critical Care. https://doi.org/10.1186/s13054-019-2617-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.