Side Effects of Mandibular Advancement Devices for Sleep Apnea Treatment
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Our purpose was to investigate side effects of sleep apnea treatment by removable oral appliances (OA) that advance the mandible. In 22 patients suffering from obstructive sleep apnea (OSA), questionnaire evaluations, polysomnographies, cephalographies, and dental plaster casts were obtained before initiation of treatment with OA that fully covered both dental arches. Patients were reevaluated after 3 to 12 mo (questionnaires, polysomnographies) and 12 to 30 mo (questionnaires, cephalographies, plaster casts) during continuous treatment. Polysomnographies confirmed improved breathing by OA. All patients experienced persistent alleviation of symptoms after 12 to 30 mo and wished to continue treatment. Side effects were common but only mildly disturbing: mucosal dryness (86% of patients), tooth discomfort (59%), and hypersalivation (55%). Cephalographies revealed a decrease in the mean (+/- SE) upper incisors to maxillary plane angle from 102 +/- 2 degrees at baseline, to 101 +/- 2 degrees after 12 to 30 mo (p < 0.05). Overbite and overjet were also slightly (mean reduction < 1 mm) but significantly reduced. None of these side effects required discontinuation of treatment. OA are an effective therapy of obstructive sleep apnea. Mild side effects are common but rarely require intervention. Nevertheless, close follow-up during long-term therapy by OA is advisable in order to timely detect potentially relevant orthodontic changes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rechtschaffen, A. (1968) · Medical Entomology and Zoology · Cited by 12,675
The Sleep Disorders Questionnaire I: Creation and Multivariate Structure of SDQ
Douglass, A. B., Bomstein, R., Nino-Murcia, G., Keenan, S., Miles, L., Zarcone, V. P., Guilleminault, C., & Dement, W. C. (1994) · Sleep · doi:10.1093/sleep/17.2.160 · Cited by 559
Ferguson, K. A., Ono, T., Lowe, A. A., Keenan, S. P., & Fleetham, J. A. (1996) · Chest · doi:10.1378/chest.109.5.1269 · Cited by 495
Ferguson, K. A., Ono, T., Lowe, A. A., al-Majed, S., Love, L. L., & Fleetham, J. A. (1997) · Thorax · doi:10.1136/thx.52.4.362 · Cited by 391
Cephalometric and computed tomographic predictors of obstructive sleep apnea severity
Lowe, A. A., Fleetham, J. A., Adachi, S., & Ryan, C. F. (1995) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/s0889-5406(95)70101-x · Cited by 314
German Version of the Epworth Sleepiness Scale
Bloch, K. E., Schoch, O. D., Zhang, J. N., & Russi, E. W. (1999) · Respiration · doi:10.1159/000029408 · Cited by 296
Self-citationAssessment of the validity and utility of a sleep-symptom questionnaire.
Kump, K., Whalen, C., Tishler, P. V., Browner, I., Ferrette, V, Strohl, K. P., Rosenberg, C., & Redline, S. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.3.8087345 · Cited by 275
Clark, G. T., Blumenfeld, I., Yoffe, N., Peled, E., & Lavie, P. (1996) · Chest · doi:10.1378/chest.109.6.1477 · Cited by 266
Ryan, C. F., Love, L. L., Peat, D., Fleetham, J. A., & Lowe, A. A. (1999) · Thorax · doi:10.1136/thx.54.11.972 · Cited by 239
A Randomized, Controlled Crossover Trial of Two Oral Appliances for Sleep Apnea Treatment
BLOCH, K. E., ISELI, A., ZHANG, J. N., XIE, X., KAPLAN, V., STOECKLI, P. W., & RUSSI, E. W. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9908112 · Cited by 223
Self-citation
Cited by
Oral Appliances for Snoring and Obstructive Sleep Apnea: A Review
Ferguson, K. A., Cartwright, R., Rogers, R., & Schmidt-Nowara, W. (2006) · Sleep · doi:10.1093/sleep/29.2.244 · Cited by 687
Review of oral appliances for treatment of sleep-disordered breathing
Hoffstein, V. (2007) · Sleep and Breathing · doi:10.1007/s11325-006-0084-8 · Cited by 355
Sleep apnea: Clinical investigations in humans
Banno, K., & Kryger, M. H. (2007) · Sleep Medicine · doi:10.1016/j.sleep.2007.03.003 · Cited by 219
Aarab, G., Lobbezoo, F., Hamburger, H. L., & Naeije, M. (2010) · Clinical Oral Investigations · doi:10.1007/s00784-009-0298-9 · Cited by 216
Treatment of snoring and obstructive sleep apnea with mandibular repositioning appliances
Cistulli, P. A., Gotsopoulos, H., Marklund, M., & Lowe, A. A. (2004) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2004.04.002 · Cited by 214
Hoekema, A., Stegenga, B., & de Bont, L. G. M. (2004) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/154411130401500303 · Cited by 195
Doff, M. H. J., Finnema, K. J., Hoekema, A., Wijkstra, P. J., de Bont, L. G. M., & Stegenga, B. (2013) · Clinical Oral Investigations · doi:10.1007/s00784-012-0737-x · Cited by 192
“Changes in overbite, overjet, and anterior–posterior relationship of the occlusion as a result of long-term oral appliance therapy have also been described in previous studies [16, 18, 19, 21, 28].”
de Almeida, F. R., Lowe, A. A., Tsuiki, S., Otsuka, R., Wong, M., Fastlicht, S., & Ryan, F. (2005) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.8978 · Cited by 191
de Almeida, F. R., Lowe, A. A., Otsuka, R., Fastlicht, S., Farbood, M., & Tsuiki, S. (2006) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2005.04.034 · Cited by 182
Prospective evaluation of an oral appliance in the treatment of obstructive sleep apnea syndrome
Blanco, J., Zamarr�n, C., Abeleira Pazos, M. T., Lamela, C., & Suarez Quintanilla, D. (2005) · Sleep and Breathing · doi:10.1007/s11325-005-0003-4 · Cited by 172
Marklund, M. (2006) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2005.10.004 · Cited by 172
Huynh, N. T., Desplats, E., & Almeida, F. R. (2016) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2015.02.002 · Cited by 171
de Almeida, F. R., Lowe, A. A., Sung, J. O., Tsuiki, S., & Otsuka, R. (2006) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2005.10.001 · Cited by 160
Lawton, H. M. (2005) · The European Journal of Orthodontics · doi:10.1093/ejo/cjh067 · Cited by 127
Oral appliances and functional orthopaedic appliances for obstructive sleep apnoea in children
Carvalho, F. R., Lentini-Oliveira, D. A., Prado, L. B., Prado, G. F., & Carvalho, L. B. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005520.pub3 · Cited by 127
Metadata
- Authors
- FRITSCH, K. M., ISELI, A., RUSSI, E. W., & BLOCH, K. E.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-09-01
- Volume
- 164
- Issue
- 5
- Pages
- 813-818
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2151609530
- Cited by
- 220
- References
- 21
- FWCI
- 3.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.