CoChat

Ventilation-Perfusion Mismatching in Chronic Obstructive Pulmonary Disease during Ventilator Weaning

Torres, Antoni, Reyes, Antonio, Roca, Josep, Wagner, Peter D., Rodriguez-Roisin, Robert · 1989 · American Review of Respiratory Disease
Cited by 97

The DOI matches its Crossref record.

Abstract

Abstract Using the multiple inert gas elimination technique, we studied ventilation-perfusion ( a/) relationships in eight patients with chronic obstructive pulmonary disease (COPD) during mechanical ventilation (MV) and again during weaning (spontaneous ventilation [SV] through an endotracheal tube) from MV needed for acute respiratory failure. The patients, seven men and one woman with a mean age of 63 ± 2.8 (SEM) yr (FEV1 33 ± 5.2% of predicted), required MV for 9.0 ± 2.4 days prior to the study. The patients were studied at maintenance Fi O2 (0.28 to 0.40) while breathing 100% O2, both during MV and SV. After 30 min of SV, PaCO2 increased from 48.9 ± 3.4 to 58.3 ± 3.1 mm Hg (p = 0.003) and pH decreased from 7.42 ± 0.01 to 7.36 ± 0.01 (p = 0.001) without significant changes in PaO2. Despite a decrease in tidal volume (Vt) from 700.0 ± 41.1 during MV to 313.0 ± 39.6 ml during SV (p = 0.001), minute ventilation remained unchanged (from 8.2 ± 0.7 during MV to 7.4 ± 0.6 L/min during SV). Furthermore, cardiac output ( t), oxygen delivery ( O2), and mixed venous PO2 (P O2) significantly rose during SV when compared with the MV ( t: from 4.7 ± 0.4 to 6.7 ± 0.7 L/min, p = 0.011; O2: from 857.3 ± 113.0 to 1078.5 ± 158.9 ml/min, p = 0.007; P O2: from 36.7 ± 1.1 to 42.3 ± 2.2 mm Hg, p = 0.041). Overall a/ inequality worsened as blood flow was redistributed to low a/ areas (from 9.4 ± 4.4 to 19.6 ± 5.3% of t, p = 0.05). The dispersion of the ventilation distribution (log SDV) significantly worsened during SV (from 1.0 ± 0.08 during MV to 1.2 ± 0.08 during SV, p = 0.044). No changes were observed in either series dead space or ventilation of high a/ ratio units. During both MV and SV, administration of 100% O2 did not increase pulmonary shunting although the dispersion of the pulmonary blood flow distribution (log SDQ) increased significantly (from 1.40 ± 0.1 to 1.56 ± 0.2 during MV and from 1.47 ± 0.2 to 1.63 ± 0.2 during SV, p = 0.014 each; normal range, 0.3 to 0.6), suggesting release of hypoxic pulmonary vasoconstriction. Our results show that discontinuing MV in these patients leads to increased a/ mismatch associated with both a less efficient breathing pattern and changes in t. The increase of cardiac output prevented a drop in PaO2 when patients were removed from MV. Thus, both intrapulmonary and extrapulmonary factors change acutely during weaning from MV. Despite the impairment in a/ inequality observed during SV, all patients could be satisfactorily weaned.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm/140.5.1246

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 97

Metadata

Authors
Torres, A., Reyes, A., Roca, J., Wagner, P. D., & Rodriguez-Roisin, R.
Venue
American Review of Respiratory Disease
Published
1989-11
Volume
140
Issue
5
Pages
1246-1250
ISSN
0003-0805 (ISSN-L)
OpenAlex
W1990099661
Cited by
97
References
0
FWCI
5.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ventilation-Perfusion Mismatching in Chronic Obstructive Pulmonary Disease during Ventilator Weaning. https://app.cochat.ai/papers/10.1164/ajrccm/140.5.1246
The paper
Torres, A., Reyes, A., Roca, J., Wagner, P. D., & Rodriguez-Roisin, R. (1989). Ventilation-Perfusion Mismatching in Chronic Obstructive Pulmonary Disease during Ventilator Weaning. American Review of Respiratory Disease. https://doi.org/10.1164/ajrccm/140.5.1246

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.