Continuous Recordings of Mixed Venous Oxygen Saturation during Weaning from Mechanical Ventilation and the Ramifications Thereof
Abstract
To define the importance of hemodynamic performance and global tissue oxygenation in determining weaning outcome, we recorded mixed venous oxygen saturation (SvO2) continuously in eight ventilator-supported patients who failed a trial of spontaneous breathing and 11 patients who tolerated a trial and were successfully extubated. Immediately before the weaning trial, SvO2 was not statistically different in the two groups (p = 0.28). On discontinuation of the ventilator, SvO2 fell progressively in the failure group (p < 0.01), whereas it did not change in the success group. During the trial of spontaneous breathing, O2 demand was similar in the two groups, but it differed in the manner with which it was met. The success group demonstrated an increase in cardiac index (p < 0.05) and O2 transport (p < 0.02). The failure group did not increase O2 transport, partly because of elevations in right- and left-ventricular afterload, but, instead, increased O2 extraction ratio (p < 0.02) with a consequent fall in SvO2. In turn, the low SvO2 combined with greater venous admixture (p < 0.0006) led to rapid arterial desaturation (p < 0.006) and a relative decrease in O2 being supplied to the tissues. In conclusion, ventilator-supported patients who failed a trial of spontaneous breathing developed a progressive decrease in SvO2 caused by the combination of a relative decrease in convective O2 transport and an increase in O2 extraction by the tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Comparison of Four Methods of Weaning Patients from Mechanical Ventilation
Esteban, A., Frutos, F., Tobin, M. J., Alía, I., Solsona, J. F., Valverdu, V., Fernández, R., de la Cal, M. A., Benito, S., Tomás, R., et al. (1995) · New England Journal of Medicine · doi:10.1056/nejm199502093320601 · Cited by 1,549
Self-citationBrochard, L., Rauss, A., Benito, S., Conti, G., Mancebo, J., Rekik, N., Gasparetto, A., & Lemaire, F. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.4.7921460 · Cited by 1,122
Oxygen utilization and ventilation during exercise in patients with chronic cardiac failure.
Weber, K. T., Kinasewitz, G. T., Janicki, J. S., & Fishman, A. P. (1982) · Circulation · doi:10.1161/01.cir.65.6.1213 · Cited by 917
Effect of Intrathoracic Pressure on Left Ventricular Performance
Buda, A. J., Pinsky, M. R., Ingels, N. B., Daughters, G. T., Stinson, E. B., & Alderman, E. L. (1979) · New England Journal of Medicine · doi:10.1056/nejm197908303010901 · Cited by 823
Cardiac output during submaximal and maximal work
Åstrand, P.-O., Cuddy, T. E., Saltin, B., & Stenberg, J. (1964) · Journal of Applied Physiology · doi:10.1152/jappl.1964.19.2.268 · Cited by 722
Gattinoni, L., Pesenti, A., Bombino, M., Baglioni, S., Rivolta, M., Rossi, F., Rossi, G., Fumagalli, R., Marcolin, R., Mascheroni, D., et al. (1988) · Anesthesiology · doi:10.1097/00000542-198812000-00005 · Cited by 664
Acute Left Ventricular Dysfunction during Unsuccessful Weaning from Mechanical Ventilation
Lemaire, F., Teboul, J.-L., Cinotti, L., Giotto, G., Abrouk, F., Steg, G., Macquin-Mavier, I., & Zapol, W. M. (1988) · Anesthesiology · doi:10.1097/00000542-198808000-00004 · Cited by 570
Pathophysiology of cor pulmonale in chronic obstructive pulmonary disease. Part One.
MacNee, W. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.3.8087359 · Cited by 488
Oxygen delivery and uptake in dogs during anemic and hypoxic hypoxia
Cain, S. M. (1977) · Journal of Applied Physiology · doi:10.1152/jappl.1977.42.2.228 · Cited by 476
Jubran, A., & Tobin, M. J. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.3.9117025 · Cited by 463
Self-citation
Cited by
Weaning from mechanical ventilation
Boles, J.-M., Bion, J., Connors, A., Herridge, M., Marsh, B., Melot, C., Pearl, R., Silverman, H., Stanchina, M., Vieillard-Baron, A., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00010206 · Cited by 2,064
Evidence-Based Guidelines for Weaning and Discontinuing Ventilatory Support
MacIntyre, N. R. (2001) · Chest · doi:10.1378/chest.120.6_suppl.375s · Cited by 1,240
Esophageal and transpulmonary pressure in the clinical setting: meaning, usefulness and perspectives
Mauri, T., Yoshida, T., Bellani, G., Goligher, E. C., Carteaux, G., Rittayamai, N., Mojoli, F., Chiumello, D., Piquilloud, L., Grasso, S., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4400-x · Cited by 554
Self-citationNoninvasive ventilation to prevent respiratory failure after extubation in high-risk patients*
Nava, S., Gregoretti, C., Fanfulla, F., Squadrone, E., Grassi, M., Carlucci, A., Beltrame, F., & Navalesi, P. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000186416.44752.72 · Cited by 552
Advances in Mechanical Ventilation
Tobin, M. J. (2001) · New England Journal of Medicine · doi:10.1056/nejm200106283442606 · Cited by 475
Self-citation
Metadata
- Authors
- JUBRAN, A., MATHRU, M., DRIES, D., & TOBIN, M. J.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-12-01
- Volume
- 158
- Issue
- 6
- Pages
- 1763-1769
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2158586592
- Cited by
- 276
- References
- 27
- FWCI
- 7.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous Recordings of Mixed Venous Oxygen Saturation during Weaning from Mechanical Ventilation and the Ramifications Thereof. https://app.cochat.ai/papers/10.1164/ajrccm.158.6.9804056
- The paper
- JUBRAN, A., MATHRU, M., DRIES, D., & TOBIN, M. J. (1998). Continuous Recordings of Mixed Venous Oxygen Saturation during Weaning from Mechanical Ventilation and the Ramifications Thereof. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.158.6.9804056
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.