Effect of Dynamic Airway Compression on Breathing Pattern and Respiratory Sensation in Severe Chronic Obstructive Pulmonary Disease 1– 3
The DOI matches its Crossref record.
Abstract
Patients with severe COPD are frequently flow-limited during expiration at rest. When expiratory flow is at its maximum, application of negative pressure at the mouth should accentuate dynamic compression downstream from the flow-limiting segment (FLS) without substantially affecting flow or pressure upstream. The purpose of this study was to determine the ventilatory response to such intervention and to determine its effect on respiratory sensation. Such responses should reflect the effect of airway receptors downstream from the FLS. Nine patients with severe COPD (FEV1 +/- SE = 27 +/- 3% predicted) breathed into a closed-circuit apparatus that incorporated a rolling-seal spirometer. The spirometer was fitted with a linear actuator that caused mouth pressure to become negative in proportion to expiratory flow (expiratory assistance, EA). Ventilatory responses were measured during 4 min of EA (-9.7 cm H2O/L/s) and were compared with those during control periods (4 min each) before and after this (C1 and C2). Sense of breathing effort was assessed at 1-min intervals by asking the subject to point to a category scale of 1 to 5, with 1 being minimal effort and 5 indicating that breathing was very difficult. There were small but significant (p less than 0.05) decreases in TI (mean +/- SE, -0.2 +/- 0.05 s) and TE (-0.3 +/- 0.07 s), with increases in breathing frequency (+2.25 +/- 0.7) and ventilation (+1.5 +/- 0.6 L/min). No significant changes were observed in tidal volume or end-expiratory volume. The EA caused a highly significant (p less than 0.001) increase in the sense of breathing effort.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
O'Donnell, D. E., & Webb, K. A. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/148.5.1351 · Cited by 543
Self-citationPetrof, B. J., Legaré, M., Goldberg, P., Milic-Emili, J., & Gottfried, S. B. (1990) · American Review of Respiratory Disease · doi:10.1164/ajrccm/141.2.281 · Cited by 486
Manning, H. L., & Schwartzstein, R. M. (1995) · New England Journal of Medicine · doi:10.1056/nejm199512073332307 · Cited by 472
Eltayara, L., Becklake, M. R., Volta, C. A., & Milic-Emili, J. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.6.8970362 · Cited by 277
Flow limitation and dynamic hyperinflation: key concepts in modern respiratory physiology
Calverley, P. M. A., & Koulouris, N. G. (2005) · European Respiratory Journal · doi:10.1183/09031936.04.00113204 · Cited by 258
Metadata
- Authors
- O'Donnell, D. E., Sanii, R., Anthonisen, N. R., & Younes, M.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1987-04
- Volume
- 135
- Issue
- 4
- Pages
- 912-918
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W1858482906
- Cited by
- 134
- References
- 0
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Dynamic Airway Compression on Breathing Pattern and Respiratory Sensation in Severe Chronic Obstructive Pulmonary Disease 1– 3. https://app.cochat.ai/papers/10.1164/arrd.1987.135.4.912
- The paper
- O'Donnell, D. E., Sanii, R., Anthonisen, N. R., & Younes, M. (1987). Effect of Dynamic Airway Compression on Breathing Pattern and Respiratory Sensation in Severe Chronic Obstructive Pulmonary Disease 1– 3. American Review of Respiratory Disease. https://doi.org/10.1164/arrd.1987.135.4.912
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.