Abstract
We tested the hypothesis that continuous positive airway pressure (CPAP) use and outcomes can be improved by an autotitrating CPAP device in patients with obstructive sleep apnea–hypopnea syndrome (OSAHS) who require higher CPAP (10 cm H2O or more). In this multisite randomized single-blind cross-over study, 44 patients (mean age, 49 ± 10 years) were randomized to 6 weeks at laboratory-determined fixed pressure and 6 weeks on autotitrating CPAP. Average nightly use was greater in automatic mode (306 versus 271 minutes, p = 0.005); median and 95th centile pressures in automatic mode were lower (p < 0.002). Automatic CPAP resulted in better SF-36 Vitality scores (65 ± 20 versus 58 ± 23, p < 0.05) and mental health scores (80 ± 14 versus 75 ± 18, p < 0.05), but no significant difference in Epworth score (p = 0.065). During automatic therapy, patients reported more restful sleep, better quality sleep, less discomfort from pressure, and less trouble getting to sleep for both the first week of therapy and for the averaged scores for Weeks 2–6 (all p values < 0.006). Patients who require higher fixed CPAP use autotitrating CPAP more and report greater benefit from this therapy.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In 4 of these studies, 186,193,198,208 there was less pressure discomfort with APAP than CPAP, and in at least 2 of the studies, less nasal irritation 186,205 or machine noise 193,205 with APAP than CPAP.”
Citations
Cites
(1992) · PubMed · Cited by 33,716
The MOS 36-ltem Short-Form Health Survey (SF-36): I. Conceptual Framework and Item Selection
Ware, J. E., & Sherbourne, C. D. (1992) · Medical Care · doi:10.1097/00005650-199206000-00002 · Cited by 30,033
A New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale
Johns, M. W. (1991) · Sleep · doi:10.1093/sleep/14.6.540 · Cited by 17,364
McHorney, C. A., Ware, J. E., Rachel Lu, J. F., & Sherbourne, C. D. (1994) · Medical Care · doi:10.1097/00005650-199401000-00004 · Cited by 4,458
Objective Measurement of Patterns of Nasal CPAP Use by Patients with Obstructive Sleep Apnea
Kribbs, N. B., Pack, A. I., Kline, L. R., Smith, P. L., Schwartz, A. R., Schubert, N. M., Redline, S., Henry, J. N., Getsy, J. E., & Dinges, D. F. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.4.887 · Cited by 1,339
Jenkinson, C., Davies, R. J., Mullins, R., & Stradling, J. R. (1999) · The Lancet · doi:10.1016/s0140-6736(98)10532-9 · Cited by 826
Long-term Use of CPAP Therapy for Sleep Apnea/Hypopnea Syndrome
McARDLE, N., DEVEREUX, G., HEIDARNEJAD, H., ENGLEMAN, H. M., MACKAY, T. W., & DOUGLAS, N. J. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.4.9807111 · Cited by 820
Self-citationFACCENDA, J. F., MACKAY, T. W., BOON, N. A., & DOUGLAS, N. J. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.2.2005037 · Cited by 631
Self-citationEngleman, H. M., Martin, S. E., Douglas, N. J., & Deary, I. J. (1994) · The Lancet · doi:10.1016/s0140-6736(94)91522-9 · Cited by 592
Self-citation
Research works printed but not linked: 6
- 2000, Sleep, 23, S102
- 1982, Am Rev Respir Dis, 126, 625
- 2001, Sleep, 24, 96, 10.1093/sleep/24.1.96 · DOI · Paper page
- 1994, Eur Respir J, 7, 1776, 10.1183/09031936.94.07101776 · DOI · Paper page
- 2000, Sleep, 23, 645
- 2000, Sleep, 23, S150
Cited by
Adherence to Continuous Positive Airway Pressure Therapy: The Challenge to Effective Treatment
Weaver, T. E., & Grunstein, R. R. (2008) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200708-119mg · Cited by 1,680
Post-Stroke Fatigue: Epidemiology, Clinical Characteristics and Treatment
Acciarresi, M., Bogousslavsky, J., & Paciaroni, M. (2014) · European Neurology · doi:10.1159/000363763 · Cited by 1,417
Sawyer, A. M., Gooneratne, N. S., Marcus, C. L., Ofer, D., Richards, K. C., & Weaver, T. E. (2011) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2011.01.003 · Cited by 900
Patil, S. P., Ayappa, I. A., Caples, S. M., Kimoff, R. J., Patel, S. R., & Harrod, C. G. (2019) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7638 · Cited by 721
Antic, N. A., Catcheside, P., Buchan, C., Hensley, M., Naughton, M. T., Rowland, S., Williamson, B., Windler, S., & McEvoy, R. D. (2011) · Sleep · doi:10.1093/sleep/34.1.111 · Cited by 533
Qaseem, A., Dallas, P., Owens, D. K., Starkey, M., Holty, J.-E. C., Shekelle, P., & for the Clinical Guidelines Committee of the American College of Physicians* (2014) · Annals of Internal Medicine · doi:10.7326/m12-3187 · Cited by 516
Arias, M. A., García-Río, F., Alonso-Fernández, A., Mediano, O., Martínez, I., & Villamor, J. (2005) · Circulation · doi:10.1161/circulationaha.104.501841 · Cited by 420
Morgenthaler, T. I., Aurora, R. N., Brown, T., Zak, R., Alessi, C., Boehlecke, B., Chesson, A. L., Friedman, L., Kapur, V., Maganti, R., et al. (2008) · Sleep · doi:10.1093/sleep/31.1.141 · Cited by 334
Pulmonary hypertension in obstructive sleep apnoea: effects of continuous positive airway pressure
Arias, M. A., García-Río, F., Alonso-Fernández, A., Martínez, I., & Villamor, J. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi807 · Cited by 319
Weaver, T. E., & Sawyer, A. M. (2010) · PubMed · Cited by 390
Qaseem, A., Holty, J.-E. C., Owens, D. K., Dallas, P., Starkey, M., & Shekelle, P. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-159-7-201310010-00704 · Cited by 305
Ayas, N. T., Patel, S. R., Malhotra, A., Schulzer, M., Malhotra, M., Jung, D., Fleetham, J., & White, D. P. (2004) · Sleep · doi:10.1093/sleep/27.2.249 · Cited by 255
Antic, N. A., Buchan, C., Esterman, A., Hensley, M., Naughton, M. T., Rowland, S., Williamson, B., Windler, S., Eckermann, S., & McEvoy, R. D. (2009) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200810-1558oc · Cited by 227
“Because the Mental Health and Vitality (energy) components of the SF-36 measurement have been shown to be the most responsive in previous CPAP trials in OSA (28, 29), these were analyzed separately and also were not significantly different between the two groups.”
MethodSleep apnea: Clinical investigations in humans
Banno, K., & Kryger, M. H. (2007) · Sleep Medicine · doi:10.1016/j.sleep.2007.03.003 · Cited by 219
“It has been reported that among patients requiring higher CPAP (10 cm H2O or more) there are improvements in CPAP use, symptoms of OSAS, and quality of life domains when using APAP as opposed to fixed pressure [266].”
BackgroundChai-Coetzer, C. L., Antic, N. A., Rowland, L. S., Reed, R. L., Esterman, A., Catcheside, P. G., Eckermann, S., Vowles, N., Williams, H., Dunn, S., et al. (2013) · JAMA · doi:10.1001/jama.2013.1823 · Cited by 211
Hsu, C.-Y. (2006) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2005.086686 · Cited by 202
Obstructive sleep apnoea syndrome: underestimated and undertreated
Gibson, G. J. (2004) · British Medical Bulletin · doi:10.1093/bmb/ldh044 · Cited by 169
Bravata, D. M., Concato, J., Fried, T., Ranjbar, N., Sadarangani, T., McClain, V., Struve, F., Zygmunt, L., Knight, H. J., Lo, A., et al. (2011) · Sleep · doi:10.5665/sleep.1254 · Cited by 163
Interventions to improve use of continuous positive airway pressure for obstructive sleep apnoea
Smith, I., Lasserson, T. J., & Haniffa, M. (2004) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003531.pub2 · Cited by 152
Smith, I., & Lasserson, T. J. (2009) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003531.pub3 · Cited by 151
Treatment Adherence and Outcomes in Flexible vs Standard Continuous Positive Airway Pressure Therapy
Aloia, M. S., Stanchina, M. L., Arnedt, J. T., Malhotra, A., & Millman, R. P. (2005) · CHEST Journal · doi:10.1378/chest.127.6.2085 · Cited by 162
Ip, S., D'Ambrosio, C., Patel, K., Obadan, N., Kitsios, G. D., Chung, M., & Balk, E. M. (2012) · Systematic Reviews · doi:10.1186/2046-4053-1-20 · Cited by 148
“Massie 2003 [22] 12406840 nd [≥15] nd 1.”
BackgroundMethodInfluentialSmith, L. A., Vennelle, M., Gardner, R. S., McDonagh, T. A., Denvir, M. A., Douglas, N. J., & Newby, D. E. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm131 · Cited by 120
“Indeed, our analysis of 23 patients yields a power two to four times greater than that of the previously published parallel group studies.(20,21) The entry criteria and endpoints for the current study were well defined and clinically relevant.”
BackgroundResultSelf-citationKhattak, H. K., Hayat, F., Pamboukian, S. V., Hahn, H. S., Schwartz, B. P., & Stein, P. K. (2018) · Texas Heart Institute Journal · doi:10.14503/thij-15-5678 · Cited by 118
“Autotitrating CPAP has reduced AHI and ESS scores as has fixed CPAP; however, the relative efficacy of auto-CPAP versus clinically titrated CPAP remains unclear.(58,59) Compliance with CPAP was poorer(55) (3.”
Adherence to positive airway pressure therapy
Weaver, T. E. (2006) · Current Opinion in Pulmonary Medicine · doi:10.1097/01.mcp.0000245715.97256.32 · Cited by 100
West, S. D. (2006) · Thorax · doi:10.1136/thx.2005.046300 · Cited by 93
Wilt, T. J., Niewoehner, D. E., Kim, C.-B., Kane, R. L., Linabery, A. M., Tacklind, J., MacDonald, R. H., & Rutks, I. R. (2005) · PsycEXTRA Dataset · doi:10.1037/e439492005-001 · Cited by 111
Atrial Overdrive Pacing in Patients with Sleep Apnea with Implanted Pacemaker
Lüthje, L., Unterberg-Buchwald, C., Dajani, D., Vollmann, D., Hasenfuß, G., & Andreas, S. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200409-1258oc · Cited by 83
Vennelle, M., White, S., Riha, R. L., Mackay, T. W., Engleman, H. M., & Douglas, N. J. (2010) · Sleep · doi:10.1093/sleep/33.2.267 · Cited by 74
Self-citationBravata, D. M., Concato, J., Fried, T., Ranjbar, N., Sadarangani, T., McClain, V., Struve, F., Zygmunt, L., Knight, H. J., Lo, A., et al. (2010) · Stroke · doi:10.1161/strokeaha.109.566745 · Cited by 74
Senn, O., Brack, T., Matthews, F., Russi, E. W., & Bloch, K. E. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200304-542oc · Cited by 73
“There was no difference in subjective sleepiness as assessed by Epworth scores among the two treatment modes, and vigilance was not objectively assessed ( 9 ).”
BackgroundMethodInfluentialValidierung von microMESAM® als Screeningsystem für schlafbezogene Atmungsstörungen
Wang, Y., Teschler, T., Weinreich, G., Hess, S., Wessendorf, T., & Teschler, H. (2003) · Pneumologie · doi:10.1055/s-2003-812423 · Cited by 70
Nocturnal Noninvasive Ventilation
Ozsancak, A., D’Ambrosio, C. M., & Hill, N. S. (2008) · CHEST Journal · doi:10.1378/chest.07-1527 · Cited by 77
Interrupter Resistance and Wheezing Phenotypes at 4 Years of Age
Brussee, J. E., Smit, H. A., Koopman, L. P., Wijga, A. H., Kerkhof, M., Corver, K., Vos, A. P. H., Gerritsen, J., Grobbee, D. E., Brunekreef, B., et al. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200306-800oc · Cited by 72
Auto-Adjusting Versus Fixed Positive Pressure Therapy in Mild to Moderate Obstructive Sleep Apnoea
Nolan, G. M., Doherty, L. S., & Mc Nicholas, W. T. (2007) · Sleep · doi:10.1093/sleep/30.2.189 · Cited by 66
Rigau, J., Montserrat, J. M., Wöhrle, H., Plattner, D., Schwaibold, M., Navajas, D., & Farré, R. (2006) · CHEST Journal · doi:10.1378/chest.130.2.350 · Cited by 71
Baltzan, M., Elkholi, O., & Wolkove, N. (2008) · Sleep Medicine · doi:10.1016/j.sleep.2007.12.005 · Cited by 76
Nussbaumer, Y., Bloch, K. E., Genser, T., & Thurnheer, R. (2006) · Chest · doi:10.1378/chest.129.3.638 · Cited by 63
McMillan, A., Bratton, D. J., Faria, R., Laskawiec-Szkonter, M., Griffin, S. C., Davies, R. J. O., Nunn, A., Stradling, J. R., Riha, R. L., & Morrell, M. J. (2015) · Health Technology Assessment · doi:10.3310/hta19400 · Cited by 70
Adherence to Continuous Positive Airway Pressure Therapy
Weaver, T. E., & Grunstein, R. R. (2012) · Proceedings of the American Thoracic Society · Cited by 58
Obstructive sleep apnoea syndrome: Translating science to clinical practice
McNicholas, W. T., & Silke, R. Y. A. N. (2006) · Respirology · doi:10.1111/j.1440-1843.2006.00824.x · Cited by 62
Arbitrary-Pressure Continuous Positive Airway Pressure for Obstructive Sleep Apnea Syndrome
Hukins, C. A. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200401-019oc · Cited by 54
Mulgrew, A. T., Cheema, R., Fleetham, J., Ryan, C. F., & Ayas, N. T. (2007) · Sleep and Breathing · doi:10.1007/s11325-006-0078-6 · Cited by 53
“Although this metaanalysis did not demonstrate a significant improvement in compliance with APAP, other studies have suggested that APAP may be preferred by patients, especially if their baseline CPAP pressures are elevated [20].”
ResultEvaluation of autoCPAP devices in home treatment of sleep apnea/hypopnea syndrome
Meurice, J. C., Cornette, A., Philip-Joet, F., Pepin, J. L., Escourrou, P., Ingrand, P., & Veale, D. (2007) · Sleep Medicine · doi:10.1016/j.sleep.2007.03.019 · Cited by 52
“showed that autoCPAP resulted in better QOL than with conventional CPAP when mean positive pressure was elevated [23].”
BackgroundSyndromes d’apnées du sommeil et pathologie cardiovasculaire
Bounhoure, J., Galinier, M., Didier, A. P., & Léophonte, P. (2005) · Bulletin de l Académie Nationale de Médecine · doi:10.1016/s0001-4079(19)33558-7 · Cited by 77
Management of Obstructive Sleep Apnea-Hypopnea Syndrome: Overview
Phillips, B. A., & Kryger, M. H. (2005) · Elsevier eBooks · doi:10.1016/b0-72-160797-7/50099-9 · Cited by 56
Prevalence of persistent sleep apnea in patients treated with continuous positive airway pressure.
Baltzan, M., Kassissia, I., Elkholi, O., Palayew, M., Dabrusin, R., & Wolkove, N. (2006) · PubMed · Cited by 54
Obstructive sleep apnea symptoms beyond sleepiness and snoring: effects of nasal APAP therapy
Cruz, I. A. C., Drummond, M., & Winck, J. C. (2012) · Sleep and Breathing · doi:10.1007/s11325-011-0502-4 · Cited by 50
“Recent studies report that nasal automatic positive airway pressure (APAP) has similar efficacy to CPAP in improving sleep quality and reducing daytime sleepiness, snoring, number of arousals, and apnea–hypopnea index (AHI) [11–16], while it may be more accepted by patients, increasing its compliance [14–16].”
BackgroundXu, T., Li, T., Wei, D., Feng, Y., Xian, L., Wu, H.-Q., & Xu, J. (2011) · Sleep And Breathing · doi:10.1007/s11325-011-0626-6 · Cited by 61
“Massie [24] 44 AutoSet (ResMed) Crossover 6 49±10 N/A 32±4 5.”
ResultGaletke, W., Anduleit, N., Richter, K., Stieglitz, S., & Randerath, W. J. (2008) · Respiration · doi:10.1159/000097767 · Cited by 49
Bench testing of auto-adjusting positive airway pressure devices
Abdenbi, F., Chambille, B., & Escourrou, P. (2004) · European Respiratory Journal · doi:10.1183/09031936.04.00133703 · Cited by 49
“It has been demonstrated that, in patients requiring high pressures, compliance was statistically increased [ 7 ].”
BackgroundCPAP and Bi-level PAP Therapy: New and Established Roles
Antonescu-Turcu, A., & Parthasarathy, S. (2010) · Respiratory Care · doi:10.4187/respcare.10551216 · Cited by 72
Kennedy, B., Lasserson, T. J., Wozniak, D. R., & Smith, I. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003531.pub4 · Cited by 47
Treatment of Obstructive Sleep Apnea Syndrome
Freedman, N. S. (2010) · Clinics in Chest Medicine · doi:10.1016/j.ccm.2010.02.012 · Cited by 54
Comparison of CPAP Titration at Home or the Sleep Laboratory in the Sleep Apnea Hypopnea Syndrome
Cross, M. D., Vennelle, M., Engleman, H. M., White, S., Mackay, T. W., Twaddle, S., & Douglas, N. J. (2006) · Sleep · doi:10.1093/sleep/29.11.1451 · Cited by 46
Self-citationSleep Quality, Short-Term and Long-Term CPAP Adherence
Somiah, M., Taxin, Z. H., Keating, J. M., Mooney, A. M., Norman, R. G., Rapoport, D. M., & Ayappa, I. A. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2138 · Cited by 48
Obstructive sleep apnoea in adults
Usmani, Z. A., Chai‐Coetzer, C. L., Antic, N. A., & McEvoy, R. D. (2012) · Postgraduate Medical Journal · doi:10.1136/postgradmedj-2012-131340 · Cited by 54
McArdle, N., Singh, B., Murphy, M., Gain, K. R., Maguire, C., Mutch, S., & Hillman, D. R. (2010) · Thorax · doi:10.1136/thx.2009.116756 · Cited by 43
“05 significance level (two sided),(15) assuming an SD of 115 min.(16) Variables were described using means and SDs (parametric) and medians and IQRs (non-parametric).”
MethodSelf-citationComparison of three auto-adjusting positive pressure devices in patients with sleep apnoea
Nolan, G. M., Ryan, S., O’Connor, T. M., & McNicholas, W. T. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00127205 · Cited by 43
Preference for fixed or automatic CPAP in patients with obstructive sleep apnea syndrome
MARRONE, O. (2004) · Sleep Medicine · doi:10.1016/j.sleep.2003.09.011 · Cited by 41
“Among studies directly evaluating the effects of autoCPAP on compliance to treatment, a few showed a positive effect [11–14], while others did not [15–17].”
BackgroundThe Future of Behavioral Sleep Medicine
Pigeon, W. R., Crabtree, V. M., & Scherer, M. R. (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26750 · Cited by 39
Management of Obstructive Sleep Apnea by Continuous Positive Airway Pressure
Weaver, T. E., & Sawyer, A. M. (2009) · Oral and Maxillofacial Surgery Clinics of North America · doi:10.1016/j.coms.2009.08.001 · Cited by 40
Hertegonne, K. B. C., & Bauters, F. A. (2009) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2009.07.001 · Cited by 35
BaHammam, A. S., Alassiri, S. S., Aladab, A., Alsadhan, I., Altheyab, A. M., Alrayes, A. H., Alkhawajah, M. M., & Olaish, A. H. (2015) · Saudi Medical Journal · doi:10.15537/smj.2015.8.11716 · Cited by 31
Potential therapeutic targets in obstructive sleep apnoea
Saboisky, J. P., Chamberlin, N. L., & Malhotra, A. (2009) · Expert Opinion on Therapeutic Targets · doi:10.1517/14728220903005608 · Cited by 27
“Randomised trials have shown benefits from standpoint of daytime sleepiness [104], blood pressure [105,106], quality of life, and vascular function [107].”
Traitement du SAHOS par ventilation en pression positive continue (PPC)
Portier, F., Orvoën-Frija, E., Chavaillon, J.-M., Lerousseau, L., Reybet-Degat, O., Léger, D., & Meurice, J.-C. (2010) · Revue des Maladies Respiratoires · doi:10.1016/s0761-8425(10)70019-x · Cited by 35
Furukawa, T., Suzuki, M., Ochiai, M., Kawashima, H., Yokoyama, N., & Isshiki, T. (2013) · Journal of Cardiology · doi:10.1016/j.jjcc.2013.08.013 · Cited by 27
Storesund, A. K., Johansson, A., Bjorvatn, B., & Lehmann, S. (2017) · Sleep And Breathing · doi:10.1007/s11325-017-1578-2 · Cited by 29
“Studies comparing the different modes in respect to pressure levels have shown that the therapeutic pressures are lower using an automatic mode [22].”
BackgroundAutoadjusting-CPAP effect on serum Leptin concentrations in Obstructive Sleep Apnoea patients
Drummond, M., Winck, J. C., Guimarães, J. T., Santos, A. C., Almeida, J., & Marques, J. A. (2008) · BMC Pulmonary Medicine · doi:10.1186/1471-2466-8-21 · Cited by 26
“Furthermore, although clinical and physiological efficacy of Auto-CPAP is equivalent to fixed CPAP [18,32] and despite the conclusions of numerous studies about Auto-CPAP efficacy [49-55] in controlling respiratory events and hypoxemia that is presumably implicated in plasma leptin levels [18,32], we cannot exclude th…”
BackgroundComparative assessment of several automatic CPAP devices' responses: a bench test study
Isetta, V., Navajas, D., Montserrat, J. M., & Farré, R. (2015) · ERJ Open Research · doi:10.1183/23120541.00031-2015 · Cited by 30
Berlowitz, D. J., Spong, J., Pierce, R. J., Ross, J. M., Barnes, M., & Brown, D. J. (2009) · Spinal Cord · doi:10.1038/sc.2009.56 · Cited by 25
AutoCPAP initiation at home: Optimal trial duration and cost-effectiveness
Bachour, A., Virkkala, J., & Maasilta, P. K. (2007) · Sleep Medicine · doi:10.1016/j.sleep.2007.01.010 · Cited by 25
Nguyên, X.-L., Rakotonanahary, D., Chaskalovic, J., Philippe, C., Hausser‐Hauw, C., Lebeau, B., & Fleury, B. (2007) · Sleep Medicine · doi:10.1016/j.sleep.2007.07.016 · Cited by 25
“The effectiveness of auto-CPAP as an alternative method of CPAP titration or for continual routine use has already been reported in the research literature [7,29–31].”
MethodAkahoshi, T., Akashiba, T., KAWAHARA, S., Uematsu, A., Nagaoka, K., Kiyofuji, K., Okamoto, N., HATTORI, T., Takahashi, N., & Hashimoto, S. (2009) · Respirology · doi:10.1111/j.1440-1843.2008.01454.x · Cited by 24
Bravata, D. M., Ferguson, J., Miech, E. J., Agarwal, R., McClain, V., Austin, C., Struve, F. A., FORESMAN, B. H., Li, X., Wang, Z., et al. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1654 · Cited by 23
“We use auto-titrating CPAP in the GoToSleep study because it is as effective as fixed-pressure CPAP 39,40 and because it does not require an in-laboratory sleep study for titration.”
Empiric Auto-Titrating CPAP in People with Suspected Obstructive Sleep Apnea
Drummond, F., Doelken, P., Ahmed, Q. A. A., Gilbert, G. E., Strange, C., Herpel, L. B., & Frye, M. D. (2010) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27762 · Cited by 24
Assessment of the impact on compliance of a new CPAP system in obstructive sleep apnea
Wimms, A. J., Richards, G. N., & Benjafield, A. (2012) · Sleep And Breathing · doi:10.1007/s11325-012-0651-0 · Cited by 19
“The study found that patients reported more restful, better quality sleep due to less discomfort from pressure [15].”
BackgroundChowdhury, M., Adams, S., & Whellan, D. J. (2009) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2009.08.006 · Cited by 23
Compliance with Continuous Positive Airway Pressure in Patients with Obstructive Sleep Apnea
Seo, M. Y., & Lee, S. H. (2020) · Sleep Medicine Research · doi:10.17241/smr.2020.00563 · Cited by 19
“[57] reported that auto-titrating positive airway pressure (APAP) have shown higher average daily used hours than CPAP (306 ± 114 min/24 h vs.”
BackgroundTreatment of Obstructive Sleep Apnea
Freedman, N. S. (2017) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2017.07.003 · Cited by 19
Obstructive sleep apnea ? management update
Hukins, C. (2006) · Neuropsychiatric Disease and Treatment · doi:10.2147/nedt.2006.2.3.309 · Cited by 24
Drummond, M., Winck, J. C., Guimarães, J. T., Santos, A. C., Almeida, J., & Marques, J. (2009) · Archivos de Bronconeumología · doi:10.1016/s1579-2129(09)73447-0 · Cited by 18
Skinner, T. C., McNeil, L., Olaithe, M., Eastwood, P. R., Hillman, D. R., Phang, J., Regt, T. D., & Bucks, R. S. (2013) · Sleep And Breathing · doi:10.1007/s11325-013-0828-1 · Cited by 21
Access to CPAP treatment in patients with moderate to severe sleep apnea in a Latin American City
Nogueira, J. F., Simonelli, G., GIOVINI, V. S., Angellotti, M. F., Borsini, E. E., Ernst, G., & Nigro, C. A. (2018) · Sleep Science · doi:10.5935/1984-0063.20180032 · Cited by 17
Parish, J. M., Miller, B. W., & Hentz, J. G. (2007) · Sleep And Breathing · doi:10.1007/s11325-007-0158-2 · Cited by 17
Drummond, M., Winck, J. C., Guimarães, J. T., Santos, A. C., Almeida, J., & Marques, J. (2009) · Archivos de Bronconeumología · doi:10.1016/j.arbres.2009.05.002 · Cited by 17
“So, our study could add some evidence about APAP effi cacy on reducing CV risk in OSA patients, as this therapy is a raising alternative approach to traditional CPAP able to improve symptoms(35) and patients compliance.(36)”
BackgroundStasche, N. (2006) · PubMed Central · Cited by 21
Continuous positive airway pressure therapy: new generations.
Garvey, J., & McNicholas, W. T. (2010) · PubMed · Cited by 19
Auto-adjusting positive airway pressure: the fine line between engineering and medicine
Messineo, L., White, D. P., Hete, B., Knepper, M., Berry, R. B., & Noah, W. H. (2025) · Sleep And Breathing · doi:10.1007/s11325-025-03409-w · Cited by 13
“APAP improvements included reduced machine noise [51, 53], less perceived discomfort from reduced expiratory pressure [38, 51, 53, 54 ], better subjective sleep quality [54 ], and less bloating/aerophagia [ 40].”
Sampaio, R., Pereira, M. G., & Winck, J. C. (2013) · Sleep And Breathing · doi:10.1007/s11325-013-0814-7 · Cited by 16
“This has prompted several studies to compare CPAP and APAP effectiveness [8–11], with our group recently showing the effectiveness of APAP therapy in controlling the majority of OSA symptoms beyond sleepiness and snoring [12].”
BackgroundNovel Approach to Simulate Sleep Apnea Patients for Evaluating Positive Pressure Therapy Devices
Isetta, V., Montserrat, J. M., Santano, R., Wimms, A. J., Ramanan, D., Woehrle, H., Navajas, D., & Farré, R. (2016) · PLoS ONE · doi:10.1371/journal.pone.0151530 · Cited by 13
Obstructive Sleep Apnea: Clinical Presentation, Diagnosis and Treatment
Yim, S., Jordan, A. S., & Malhotra, A. (2006) · KARGER eBooks · doi:10.1159/000093154 · Cited by 16
Treatment of Obstructive Sleep Apnea
Freedman, N. S. (2020) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2020.02.007 · Cited by 12
Phurrough, S. E., Spencer, F., Stiller, J. M., & Brechner, R. J. (2008) · Cited by 18
Bironneau, V., Ingrand, P., Pontier, S., Iamandi, C., Portel, L., Martin, F., Mallart, A., Lerousseau, L., Alfandary, D., Levrat, V., et al. (2023) · Respirology · doi:10.1111/resp.14569 · Cited by 12
“11 The improvement in daytime somnolence and comfort 9,12,13 was more marked under autoCPAP with a better compliance in the patients with a higher effective positive pressure, or with greater variability in pressure levels, 14,15 based on RCTs with small sample sizes and short treatment duration.”
BackgroundTherapieadhärenz bei CPAP-Patienten
Woehrle, H., Graml, A., & Weinreich, G. (2010) · Somnologie - Schlafforschung und Schlafmedizin · doi:10.1007/s11818-010-0470-0 · Cited by 10
Kim, H. Y., & Jang, M.-S. (2014) · Korean Journal of Otorhinolaryngology - Head and Neck Surgery · doi:10.3342/kjorl-hns.2014.57.1.7 · Cited by 9
Tobin, M. J. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2312010 · Cited by 11
Contemporary Issues in the Diagnosis and Treatment of Obstructive Sleep Apnea
Rubins, J. B., & Kunisaki, K. M. (2008) · Postgraduate Medicine · doi:10.3810/pgm.2008.07.1790 · Cited by 10
Metadata
- Authors
- Massie, C. A., McArdle, N., Hart, R. W., Schmidt-Nowara, W. W., Lankford, A., Hudgel, D. W., Gordon, N., & Douglas, N. J.
- Affiliations
- The University of Western Australia (AU)
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-01-01
- Volume
- 167
- Issue
- 1
- Pages
- 20-23
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2103235422
- Semantic Scholar
- cf8b662dfc6c2521e8c173484388160ef942ece8
- Cited by
- 177
- References
- 39
- Citations by year
- 2025: 4 · 2023: 3 · 2022: 1 · 2021: 3 · 2020: 5 · 2019: 2 · 2018: 2 · 2017: 5 · 2016: 2 · 2015: 9 · 2014: 8 · 2013: 10 · 2012: 9
- FWCI
- 5.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Respiratory and Critical Care Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Keywords
- continuous positive airway pressure, obstructive sleep apnea-hypopnea syndrome, CPAP titration, CPAP adherence, sleep quality, quality of life, daytime sleepiness, patient-reported outcomes
- MeSH terms
- Adolescent, Adult, Aged, Female, Home Care Services, Humans, Male, Middle Aged, Positive-Pressure Respiration, Quality of Life, Sleep, Treatment Outcome, Cross-Over Studies, Sleep Apnea, Obstructive
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.