CoChat

Randomized Short-term Trial of Two AutoCPAP Devices versus Fixed Continuous Positive Airway Pressure for the Treatment of Sleep Apnea

Senn, Oliver, Brack, Thomas, Matthews, Felix, Russi, Erich W., Bloch, Konrad E. · 2003 · American Journal of Respiratory and Critical Care Medicine

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Abstract

We evaluated the efficacy of two different continuous positive airway pressure devices with automatic mask pressure adjustment (autoCPAP) in comparison with fixed CPAP in treating obstructive sleep apnea syndrome in 29 patients. The mean (± SE) apnea–hypopnea index was 46 ± 4 per hour and the Epworth score was 14.2 ± 0.7. Patients were treated over three consecutive 1-month periods with three regimens in random order: an autoCPAP device responding to apnea–hypopnea and snoring, another autoCPAP device responding to snoring and changes in flow contour, and fixed CPAP at the 90th pressure percentile titrated by autoCPAP over 2 weeks. Allowed pressure in the autoCPAP mode was 4 to 15 cm H2O. At the end of each treatment period, symptoms, quality of life, vigilance, and nocturnal breathing disturbances were evaluated. All three treatment modalities improved symptoms, quality-of-life domains, and apnea–hypopnea index significantly and to a similar degree. Mean (± SE) maintenance-of-wakefulness time increased by 4.5 ± 1.8, 6.0 ± 1.5, and 6.1 ± 1.4 minutes with DeVilbiss AutoAdjust LT, AutoSet T, and fixed-pressure CPAP, respectively (p < 0.001 vs. baseline, p = not significant for comparisons among the three modalities). We conclude that both autoCPAP devices were equally effective as fixed-pressure CPAP in improving major outcomes during short-term therapy of sleep apnea.

Overview

Integrity signals

Registry

Crossref · 10.1164/rccm.200304-542oc

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 34 references

Research works printed but not linked: 29

  1. 1999, Lancet, 2100
  2. 2001, Am J Respir Crit Care Med, 608
  3. 1993, Sleep, S120
  4. 1996, Am J Respir Crit Care Med, 734
  5. 1996, Am J Respir Crit Care Med, 1755
  6. 1999, Chest, 771
  7. 1998, Chest, 714
  8. 2000, Eur Respir J, 990
  9. 2002, Am J Respir Crit Care Med, 20
  10. 1997, Ann Intern Med, 588
  11. 1996, Am J Respir Crit Care Med, 794
  12. 2001, Am J Respir Crit Care Med, 652
  13. 2002, Chest, 759
  14. 2002, Am J Respir Crit Care Med, 469
  15. 2002, Am J Respir Crit Care Med, A724
  16. 1999, Respiration (Herrlisheim), 440
  17. 1994, Am J Respir Crit Care Med, 735
  18. 1997, J Sleep Res, 142
  19. 2001, Am J Respir Crit Care Med, 1619
  20. 1997, Technol Health Care, 285
  21. 1999, Sleep, 667
  22. 1989, Med Care, S178
  23. 1986, Lancet, 307
  24. 1996, BMJ, 36
  25. 2001, Eur Respir J, 170
  26. 1997, J Sleep Res, 199
  27. 1999, Am J Respir Crit Care Med, 461
  28. 1998, Thorax, 643
  29. 2000, Sleep, 645

Cited by

See all 73

Metadata

Authors
Senn, O., Brack, T., Matthews, F., Russi, E. W., & Bloch, K. E.
Affiliations
  • University Hospital Zurich (CH)
  • University of Zurich (CH)
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2003-12
Volume
168
Issue
12
Pages
1506-1511
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2118172610
Cited by
73
References
34
Citations by year
2025: 3 · 2024: 1 · 2023: 2 · 2021: 1 · 2019: 3 · 2017: 1 · 2016: 1 · 2015: 2 · 2014: 1 · 2013: 2 · 2012: 7
FWCI
2.88
Type
journal article
Language
en
Open access
closed
Locations
  • American Journal of Respiratory and Critical Care Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
Keywords
obstructive sleep apnea, continuous positive airway pressure, apnea-hypopnea index, snoring detection, quality of life, Epworth Sleepiness Scale, CPAP titration
MeSH terms
Female, Home Care Services, Humans, Male, Middle Aged, Sleep Apnea Syndromes, Single-Blind Method, Treatment Outcome, Cross-Over Studies, Continuous Positive Airway Pressure

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Randomized Short-term Trial of Two AutoCPAP Devices versus Fixed Continuous Positive Airway Pressure for the Treatment of Sleep Apnea. https://app.cochat.ai/papers/10.1164/rccm.200304-542oc
The paper
Senn, O., Brack, T., Matthews, F., Russi, E. W., & Bloch, K. E. (2003). Randomized Short-term Trial of Two AutoCPAP Devices versus Fixed Continuous Positive Airway Pressure for the Treatment of Sleep Apnea. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.200304-542oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.