CoChat

Comparison of three auto-adjusting positive pressure devices in patients with sleep apnoea

Open access
Nolan, G. M., Ryan, S., O’Connor, T. M., McNicholas, W. T. · 2006 · European Respiratory Journal
Cited by 43

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Auto-adjustable continuous positive airway pressure (APAP) devices are an emerging treatment alternative to fixed-pressure continuous positive airway pressure (CPAP) therapy for obstructive sleep apnoea syndrome. They have been engineered to automatically adjust the pressure to the optimal level on a continuous basis. However, not all APAP technologies use the same algorithm. Three different APAP devices (Autoset Spirit, Breas PV 10i and RemStar Auto) were compared in a randomised crossover trial in patients already established on fixed-pressure CPAP therapy. The outcome measures were compliance, quality of life and side-effects. Twenty-seven middle-aged patients (25 male) previously diagnosed with severe obstructive sleep apnoea syndrome (median (interquartile range) apnoea/hypopnoea index 48 (29–76)), established on CPAP therapy for >3 yrs, were randomised to each APAP device for 4 weeks. Mean pressure and patient compliance were significantly lower on the Breas PV 10i than on the other APAP devices. The devices were similar in terms of quality of life, daytime sleepiness and upper airway side-effects, but patients evaluated them significantly differently in terms of device features, sleep quality and pressure comfort, with the Breas PV 10i being the least popular. Auto-adjustable positive airway pressure devices differ in pressure delivery and patient compliance in obstructive sleep apnoea syndrome patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.06.00127205

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 43

Metadata

Authors
Nolan, G. M., Ryan, S., O’Connor, T. M., & McNicholas, W. T.
Venue
European Respiratory Journal
Published
2006-03-29
Volume
28
Issue
1
Pages
159-164
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2105791155
Cited by
43
References
10
FWCI
2.94
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of three auto-adjusting positive pressure devices in patients with sleep apnoea. https://app.cochat.ai/papers/10.1183/09031936.06.00127205
The paper
Nolan, G. M., Ryan, S., O’Connor, T. M., & McNicholas, W. T. (2006). Comparison of three auto-adjusting positive pressure devices in patients with sleep apnoea. European Respiratory Journal. https://doi.org/10.1183/09031936.06.00127205

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.