Randomized Short-term Trial of Two AutoCPAP Devices versus Fixed Continuous Positive Airway Pressure for the Treatment of Sleep Apnea
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
We evaluated the efficacy of two different continuous positive airway pressure devices with automatic mask pressure adjustment (autoCPAP) in comparison with fixed CPAP in treating obstructive sleep apnea syndrome in 29 patients. The mean (± SE) apnea–hypopnea index was 46 ± 4 per hour and the Epworth score was 14.2 ± 0.7. Patients were treated over three consecutive 1-month periods with three regimens in random order: an autoCPAP device responding to apnea–hypopnea and snoring, another autoCPAP device responding to snoring and changes in flow contour, and fixed CPAP at the 90th pressure percentile titrated by autoCPAP over 2 weeks. Allowed pressure in the autoCPAP mode was 4 to 15 cm H2O. At the end of each treatment period, symptoms, quality of life, vigilance, and nocturnal breathing disturbances were evaluated. All three treatment modalities improved symptoms, quality-of-life domains, and apnea–hypopnea index significantly and to a similar degree. Mean (± SE) maintenance-of-wakefulness time increased by 4.5 ± 1.8, 6.0 ± 1.5, and 6.1 ± 1.4 minutes with DeVilbiss AutoAdjust LT, AutoSet T, and fixed-pressure CPAP, respectively (p < 0.001 vs. baseline, p = not significant for comparisons among the three modalities). We conclude that both autoCPAP devices were equally effective as fixed-pressure CPAP in improving major outcomes during short-term therapy of sleep apnea.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A total of 11 studies reported data on side effe cts, 179,183,186,188,191,[193][194][195][196]198,205 with 6 of the studies 179,183,188,191,195,196 reporting no clinically significant differences in side effects between APAP and CPAP.”
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
SF-36 health survey: Manual and interpretation guide
Ware, J. (2003) · Medical Entomology and Zoology · Cited by 11,424
McNicholas, W. T., Strohl, K. P., White, D. P., Levy, P. A., Schmidt, W., Wheatley, J. R., Redline, S. S., Carley, D. W., Buysse, D. J., Young, T. B., et al. (1999) · PubMed · Cited by 3,665
Effect Sizes for Interpreting Changes in Health Status
Kazis, L. E., Anderson, J. J., & Meenan, R. F. (1989) · Medical Care · doi:10.1097/00005650-198903001-00015 · Cited by 2,401 · cited 4×
“Magnitudes of treatment benefit were assessed by computing effect sizes for outcome variables as ratio of the mean difference to baseline divided by the SD of the mean at baseline ( 24 ).”
BackgroundMethodInfluentialAn Introduction to Medical Statistics.
(1931) · Journal of the American Medical Association · doi:10.1001/jama.1931.02730150055037 · Cited by 2,084
Trials to assess equivalence: the importance of rigorous methods: Fig 1
Jones, B., Jarvis, P., Lewis, J. A., & Ebbutt, A. F. (1996) · BMJ · doi:10.1136/bmj.313.7048.36 · Cited by 1,032
Turner‐Bowker, D. M., DeRosa, M., & Ware, J. E. (2008) · eScholarship@UMassChan · Cited by 954
Jenkinson, C., Davies, R. J., Mullins, R., & Stradling, J. R. (1999) · The Lancet · doi:10.1016/s0140-6736(98)10532-9 · Cited by 826 · cited 6×
“The benefits of CPAP therapy observed in the current study with automatic and fixed-pressure mode in patients with moderate to severe obstructive sleep apnea are similar to those reported in previous studies with conventional fixed CPAP treatment ( 1 , 2). To allow comparisons of the magnitude of treatment effects ach…”
BackgroundMethodResultInfluentialENGLEMAN, H. M., KINGSHOTT, R. N., WRAITH, P. K., MACKAY, T. W., DEARY, I. J., & DOUGLAS, N. J. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.2.9803121 · Cited by 558 · cited 1×
“With a mean nightly use of 5.5 to 5.6 hours during automatic and fixed-pressure mode therapy, respectively, treatment adherence in the current study was similar to the 5.4 hours observed with fixed CPAP treatment in patients with comparable severity of the disease (1) but higher than the 2.8 hours/ night found in some…”
MethodInfluential
Research works printed but not linked: 29
- 1999, Lancet, 2100
- 2001, Am J Respir Crit Care Med, 608
- 1993, Sleep, S120
- 1996, Am J Respir Crit Care Med, 734
- 1996, Am J Respir Crit Care Med, 1755
- 1999, Chest, 771
- 1998, Chest, 714
- 2000, Eur Respir J, 990
- 2002, Am J Respir Crit Care Med, 20
- 1997, Ann Intern Med, 588
- 1996, Am J Respir Crit Care Med, 794
- 2001, Am J Respir Crit Care Med, 652
- 2002, Chest, 759
- 2002, Am J Respir Crit Care Med, 469
- 2002, Am J Respir Crit Care Med, A724
- 1999, Respiration (Herrlisheim), 440
- 1994, Am J Respir Crit Care Med, 735
- 1997, J Sleep Res, 142
- 2001, Am J Respir Crit Care Med, 1619
- 1997, Technol Health Care, 285
- 1999, Sleep, 667
- 1989, Med Care, S178
- 1986, Lancet, 307
- 1996, BMJ, 36
- 2001, Eur Respir J, 170
- 1997, J Sleep Res, 199
- 1999, Am J Respir Crit Care Med, 461
- 1998, Thorax, 643
- 2000, Sleep, 645
Cited by
Patil, S. P., Ayappa, I. A., Caples, S. M., Kimoff, R. J., Patel, S. R., & Harrod, C. G. (2019) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7638 · Cited by 721
Qaseem, A., Dallas, P., Owens, D. K., Starkey, M., Holty, J.-E. C., Shekelle, P., & for the Clinical Guidelines Committee of the American College of Physicians* (2014) · Annals of Internal Medicine · doi:10.7326/m12-3187 · Cited by 516
Morgenthaler, T. I., Aurora, R. N., Brown, T., Zak, R., Alessi, C., Boehlecke, B., Chesson, A. L., Friedman, L., Kapur, V., Maganti, R., et al. (2008) · Sleep · doi:10.1093/sleep/31.1.141 · Cited by 334
Qaseem, A., Holty, J.-E. C., Owens, D. K., Dallas, P., Starkey, M., & Shekelle, P. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-159-7-201310010-00704 · Cited by 305
Craig, S. E., Kohler, M., Nicoll, D., Bratton, D. J., Nunn, A., Davies, R., & Stradling, J. (2012) · Thorax · doi:10.1136/thoraxjnl-2012-202178 · Cited by 228
Interventions to improve use of continuous positive airway pressure for obstructive sleep apnoea
Smith, I., Lasserson, T. J., & Haniffa, M. (2004) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003531.pub2 · Cited by 152
Rosati, M. (2011) · Studies in bilingualism · doi:10.1075/sibil.43.20add · Cited by 152
Smith, I., & Lasserson, T. J. (2009) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003531.pub3 · Cited by 151
Ip, S., D'Ambrosio, C., Patel, K., Obadan, N., Kitsios, G. D., Chung, M., & Balk, E. M. (2012) · Systematic Reviews · doi:10.1186/2046-4053-1-20 · Cited by 148
“Senn 2003 [25] Switzerland 14525804 46 (23) [> 10] 14.”
BackgroundMethodInfluentialEl-Solh, A., Moitheennazima, B., Akinnusi, M. E., Churder, P. M., & Lafornara, A. M. (2010) · Sleep And Breathing · doi:10.1007/s11325-010-0437-1 · Cited by 137
“In a meta-analysis of published randomized trials comparing auto-CPAP to fixed-pressure CPAP devices, Ayas and coworkers [16] observed that the average applied overnight pressure was significantly lower with auto-CPAP while comparably low AHIs were achieved; however, Senn and colleagues [17] showed in a randomized tri…”
Air Leak is Associated with Poor Adherence to Autopap Therapy
Valentin, A., Subramanian, S., Quan, S. F., Berry, R. B., & Parthasarathy, S. (2011) · Sleep · doi:10.5665/sleep.1054 · Cited by 96
“Vibratory snore index 14 (7, 20) 21 (14, 47)**”
Latshang, T. D., Nussbaumer‐Ochsner, Y., Henn, R. M., Ulrich, S., Cascio, C. M. L., Ledergerber, B., Kohler, M., & Bloch, K. E. (2012) · JAMA · doi:10.1001/jama.2012.94847 · Cited by 101
“REM, %g 19 (14-24) 23 (18-28)c 19 (14-22)d 17 (14-23)e 17 (13-21)e .”
BackgroundSelf-citationPositive Pressure Therapy: A Perspective on Evidence-based Outcomes and Methods of Application
Sanders, M. H., Montserrat, J. M., Farré, R., & Givelber, R. J. (2008) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200709-150mg · Cited by 75
Vennelle, M., White, S., Riha, R. L., Mackay, T. W., Engleman, H. M., & Douglas, N. J. (2010) · Sleep · doi:10.1093/sleep/33.2.267 · Cited by 74
Auto-Adjusting Versus Fixed Positive Pressure Therapy in Mild to Moderate Obstructive Sleep Apnoea
Nolan, G. M., Doherty, L. S., & Mc Nicholas, W. T. (2007) · Sleep · doi:10.1093/sleep/30.2.189 · Cited by 66
Rigau, J., Montserrat, J. M., Wöhrle, H., Plattner, D., Schwaibold, M., Navajas, D., & Farré, R. (2006) · CHEST Journal · doi:10.1378/chest.130.2.350 · Cited by 71
McMillan, A., Bratton, D. J., Faria, R., Laskawiec-Szkonter, M., Griffin, S. C., Davies, R. J. O., Nunn, A., Stradling, J. R., Riha, R. L., & Morrell, M. J. (2015) · Health Technology Assessment · doi:10.3310/hta19400 · Cited by 70
Nussbaumer, Y., Bloch, K. E., Genser, T., & Thurnheer, R. (2006) · Chest · doi:10.1378/chest.129.3.638 · Cited by 63
Self-citationSenn, O., Brack, T., Russi, E. W., & Bloch, K. E. (2006) · CHEST Journal · doi:10.1378/chest.129.1.67 · Cited by 65
Self-citationObstructive sleep apnoea syndrome: Translating science to clinical practice
McNicholas, W. T., & Silke, R. Y. A. N. (2006) · Respirology · doi:10.1111/j.1440-1843.2006.00824.x · Cited by 62
Evaluation of autoCPAP devices in home treatment of sleep apnea/hypopnea syndrome
Meurice, J. C., Cornette, A., Philip-Joet, F., Pepin, J. L., Escourrou, P., Ingrand, P., & Veale, D. (2007) · Sleep Medicine · doi:10.1016/j.sleep.2007.03.019 · Cited by 52
CPAP and Bi-level PAP Therapy: New and Established Roles
Antonescu-Turcu, A., & Parthasarathy, S. (2010) · Respiratory Care · doi:10.4187/respcare.10551216 · Cited by 72
Treatment of Obstructive Sleep Apnea Syndrome
Freedman, N. S. (2010) · Clinics in Chest Medicine · doi:10.1016/j.ccm.2010.02.012 · Cited by 54
Kennedy, B., Lasserson, T. J., Wozniak, D. R., & Smith, I. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003531.pub4 · Cited by 47
Comparison of three auto-adjusting positive pressure devices in patients with sleep apnoea
Nolan, G. M., Ryan, S., O’Connor, T. M., & McNicholas, W. T. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00127205 · Cited by 43
Effect of air leak on the performance of auto-PAP devices: a bench study
Coller, D., Stanley, D., & Parthasarathy, S. (2005) · Sleep And Breathing · doi:10.1007/s11325-005-0032-z · Cited by 40
“devices do not perform differently in clinical studies [5, 25].”
BackgroundBloch, K. E., Huber, F., Furian, M., Latshang, T. D., Lo Cascio, C. M., Nussbaumer-Ochsner, Y., Senn, O., Russi, E. W., Kohler, M., Schoch, O. D., et al. (2018) · Thorax · doi:10.1136/thoraxjnl-2016-209699 · Cited by 35
Self-citationHertegonne, K. B. C., & Bauters, F. A. (2009) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2009.07.001 · Cited by 35
Li, X., Dong, Z., Wan, Y., & Wang, Z. (2009) · The Aging Male · doi:10.3109/13685530903406789 · Cited by 36
Reliability of home CPAP titration with different automatic CPAP devices
Sériès, F., Plante, J., & Lacasse, Y. (2008) · Respiratory Research · doi:10.1186/1465-9921-9-56 · Cited by 30
“Nasal continuous positive airway pressure (CPAP) represents a very effective treatment for OSAHS as demonstrated by the results of different randomized controlled [ 8-11 ] and non-randomized trials [12].”
BackgroundMethodAkahoshi, T., Akashiba, T., KAWAHARA, S., Uematsu, A., Nagaoka, K., Kiyofuji, K., Okamoto, N., HATTORI, T., Takahashi, N., & Hashimoto, S. (2009) · Respirology · doi:10.1111/j.1440-1843.2008.01454.x · Cited by 24
Luo, J., Xiao, S., Qiu, Z., Song, N., & Luo, Y. (2012) · Respirology · doi:10.1111/resp.12014 · Cited by 27
Titration procedures for nasal CPAP: Automatic CPAP or prediction formula?
Hertegonne, K. B. C., Volná, J., Portier, S., Pauw, R. D., Maele, G. V., & Pevernagie, D. (2007) · Sleep Medicine · doi:10.1016/j.sleep.2007.08.009 · Cited by 22
“In previous reports, evidence was provided indicating that an A-CPAP titration procedure is as efficient as manual titration in assuring respiratory control [4], and that the 90th [5,6] or 95th percentiles [7–10] of the pressure titrated by A-CPAP have been suggested as reference pressure levels for F-CPAP treatment a…”
MethodEmpiric Auto-Titrating CPAP in People with Suspected Obstructive Sleep Apnea
Drummond, F., Doelken, P., Ahmed, Q. A. A., Gilbert, G. E., Strange, C., Herpel, L. B., & Frye, M. D. (2010) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27762 · Cited by 24
Dungan, G. C., Marshall, N. S., Hoyos, C. M., Yee, B. J., & Grunstein, R. R. (2011) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1066 · Cited by 19
Continuous positive airway pressure therapy: new generations.
Garvey, J., & McNicholas, W. T. (2010) · PubMed · Cited by 19
Hertegonne, K. B. C., Rombaut, B., Houtmeyers, P., Maele, G. V., & Pevernagie, D. (2007) · Respiration · doi:10.1159/000103515 · Cited by 15
Auto-adjusting positive airway pressure: the fine line between engineering and medicine
Messineo, L., White, D. P., Hete, B., Knepper, M., Berry, R. B., & Noah, W. H. (2025) · Sleep And Breathing · doi:10.1007/s11325-025-03409-w · Cited by 13
“…(e.g., Osler, multiple wakefulness test) [23, 27, 38, 40, 41, 43, 44, 46, 47, 49 , 51, 53 – 56, 59 , 62 – 67, 69 ], in quality of life [38, 40, 41, 43, 51, 53, 55, 59 , 65 – 67 ] and in the AHI [ 23, 38 – 41, 43 – 47, 49 , 51, 52, 54 – 56, 59 , 62 – 67, 69– 71] were similar to those seen with CPAP.”
Bironneau, V., Ingrand, P., Pontier, S., Iamandi, C., Portel, L., Martin, F., Mallart, A., Lerousseau, L., Alfandary, D., Levrat, V., et al. (2023) · Respirology · doi:10.1111/resp.14569 · Cited by 12
“Meta-analysis of RCTs 9 concluded that treatment effects and adherence were similar between APAP and fixed CPAP.”
BackgroundMethodResultInfluentialPositive Airway Pressure Treatment for Obstructive Sleep Apnea–Hypopnea Syndrome
Buchanan, P. R., & Grunstein, R. R. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4160-6645-3.00107-9 · Cited by 15
Shi, H., Cheng, L., Nakayama, M., Kakazu, Y., Yin, M., Miyoshi, A., & Komune, S. (2005) · Auris Nasus Larynx · doi:10.1016/j.anl.2005.03.007 · Cited by 13
“[8] first compared the efficiency of two auto-CPAP devices operated by different algorithms.”
BackgroundDamiani, M. F., Quaranta, V. N., Tedeschi, E., Drigo, R., Ranieri, T., Carratù, P., & Resta, O. (2013) · Respirology · doi:10.1111/resp.12098 · Cited by 11
Vidigal, T. D. A., Brasil, E. L., Ferreira, M. N., Mello-Fujita, L., Moreira, G. A., Drager, L. F., Soster, L. A., Genta, P. R., Poyares, D. R., & Haddad, F. L. M. (2021) · Sleep Science · doi:10.5935/1984-0063.20200086 · Cited by 13
“…can also be explained by other adverse effects related to the use of the equipment, such as mask intolerance, dry nose and mouth, fragmented sleep, equipment noise, skin irritation, positive pressure intolerance - including difficulty in exhaling and air leakage from the mask or mouth 33-35 .”
BackgroundNew Approaches to Positive Airway Pressure Treatment in Obstructive Sleep Apnea
Kuźniar, T. J. (2016) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2016.03.002 · Cited by 9
Sangal, R. B., & Sudan, N. (2019) · Clinical EEG and Neuroscience · doi:10.1177/1550059419892759 · Cited by 9
Tobin, M. J. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2312010 · Cited by 11
Pordzik, J., Ludwig, K., Seifen, C., Ruckes, C., Huppertz, T., Bahr‐Hamm, K., Hackenberg, B., Matthias, C., & Gouveris, H. T. (2024) · Respiratory Medicine · doi:10.1016/j.rmed.2024.107750 · Cited by 9
Hailey, D. M., Jacobs, P., Mayers, I., & Mensinkai, S. (2005) · Canadian Respiratory Journal · doi:10.1155/2005/870786 · Cited by 9
Introduction to Modern Sleep Technology
Chiang, R. P., & Kang, S.-C. (2012) · International series on intelligent systems, control and automation: science and engineering · doi:10.1007/978-94-007-5470-6 · Cited by 9
APAP and Alternative Titration Methods
Ahmed, O. I., & Parthasarathy, S. (2010) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2010.05.010 · Cited by 9
“In a cross-over study design with three conditions and 1-month period of therapy, Senn and colleagues two different APAP devices and CPAP therapy based on pressure level determined following 2-weeks of APAP therapy (33).”
MethodContinuous Positive Airway Pressure Treatment and Adherence in Obstructive Sleep Apnea
Matthews, E. E., & Aloia, M. S. (2009) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2009.07.004 · Cited by 10
Fulda, S., & Schulz, H. (2010) · Progress in brain research · doi:10.1016/b978-0-444-53702-7.00005-1 · Cited by 8
“In a few studies, one PAP treatment was compared to another PAP treatment (Bakker et al., 2010; Marshall et al., 2008; Meurice et al., 1998; Senn et al., 2003) or to withdrawal of treatment (Kribbs et al.”
Methodd’Ortho, M. (2004) · Current Opinion in Pulmonary Medicine · doi:10.1097/01.mcp.0000144438.73152.4a · Cited by 8
Positive Airway Pressure Therapy for Obstructive Sleep Apnea
Lee-Chiong, T. L., & Hirshkowitz, M. (2006) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2006.11.002 · Cited by 8
Randomised short-term trial of high-span versus low-span APAP for treating sleep apnoea
Bastos, H. N., Cardoso, A. V., Castro, A. S., Gomes, R., Pinto, T., Marinho, A., Sucena, M., Almeida, J., Drummond, M., & Winck, J. C. (2015) · Sleep And Breathing · doi:10.1007/s11325-015-1203-1 · Cited by 7
Treatment of obstructive sleep-disordered breathing with positive airway pressure systems
Pevernagie, D., Masa, J. F., Meurice, J. C., Farré, R., Marrone, O., & Rodenstein, D. O. (2007) · European Respiratory Review · doi:10.1183/09059180.00010603 · Cited by 5
Management of Obstructive Sleep Apnea in Hospitalized Patients
Khalid, A., Mukundan, T. H., Khalid, R., Pusalavidyasagar, S. S., & Khan, A. (2023) · Applied Sciences · doi:10.3390/app13042108 · Cited by 5
Pordzik, J., Ludwig, K., Ruckes, C., & Gouveris, H. T. (2025) · Nature and Science of Sleep · doi:10.2147/nss.s495106 · Cited by 3
“26,27 Interestingly, the adherence time did not significantly correlate with ∆ AHI at the time of the performed PSG.”
Automatic Positive Airway Pressure Titration and Treatment
Randerath, W. J. (2006) · KARGER eBooks · doi:10.1159/000093156 · Cited by 3
Sleep-Related Breathing Disorders and Quality of Life
Sharafkhaneh, H., & Sharafkhaneh, A. (2006) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2006.10.003 · Cited by 2
Positive Airway Pressure Treatment of Adult Patients with Obstructive Sleep Apnea
Desai, T., Khan, M. S., & Bhatt, N. Y. (2010) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2010.05.003 · Cited by 4
Haldar, A. K., Dhar, R., Maity, S., Krishnan, S., Bhattacharya, A., & Sovani, M. P. (2025) · Lung India · doi:10.4103/lungindia.lungindia_572_24 · Cited by 1
Trastornos respiratorios del sueño: guías clínicas para el diagnóstico y tratamiento
López, V., Musetti, A., Mamchur, M., Salazar, M. L. G., Otaño, N., Umpiérrez, A., Chiappella, L., Frattini, R., Barros, A., Lorenzo, D., et al. (2012) · Revista Médica del Uruguay · Cited by 7
Positive Airway Pressure Therapy for Obstructive Sleep Apnea/Hypopnea Syndrome
Freedman, N. S. (2007) · Humana Press eBooks · doi:10.1007/978-1-59745-421-6_12 · Cited by 3
“Senn et al. ( 69 ) compared two APAP devices with conventional CPAP in a clinical trial of 29 patients with OSAS.”
Positive Airway Pressure Therapy for Obstructive Sleep Apnea
Kanathur, N., Hirshkowitz, M., & Lee-Chiong, T. L. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4377-1703-7.10016-7 · Cited by 2
Impacto da toracocentese de alívio sobre o sono em pacientes com derrame pleural volumoso
Marcondes, B. F. (2011) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.5.2011.tde-23082011-134915
Randerath, W. J., & Galetke, W. (2008) · Somnologie - Schlafforschung und Schlafmedizin · doi:10.1007/s11818-008-0364-6 · Cited by 1
Management of Sleep Disorders: CPAP (Continuous Positive Airway Pressure)
Ramar, K. (2012) · International series on intelligent systems, control and automation: science and engineering · doi:10.1007/978-94-007-5470-6_4
Positive Pressure Therapy; When CPAP fails, what other PAP modalities are?
Joo, E. Y. (2008) · Journal of Korean Sleep Research Society · doi:10.13078/jksrs.08011
Obstructive Sleep Apnea: Diagnosis with Polysomnography and Portable Monitors
Zhang, C., Kales, S. N., & Malhotra, A. (2011) · Humana Press eBooks · doi:10.1007/978-1-60761-735-8_3
Some Points to Ponder through Some New and Old Concepts in Sleep Medicine
Kumar, T. M. (2006) · Indian Journal of Sleep Medicine · doi:10.5005/ijsm-1-2-78
“In a classical study done in about 3 months time it was proved beyond doubt that both delivered equally efficacious treatment for the patients(20).”
Background
Metadata
- Authors
- Senn, O., Brack, T., Matthews, F., Russi, E. W., & Bloch, K. E.
- Affiliations
- University Hospital Zurich (CH)
- University of Zurich (CH)
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-12
- Volume
- 168
- Issue
- 12
- Pages
- 1506-1511
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2118172610
- Semantic Scholar
- 48a7e8de9a94d8f02b664f76fb7152fa2740fab9
- Cited by
- 73
- References
- 34
- Citations by year
- 2025: 3 · 2024: 1 · 2023: 2 · 2021: 1 · 2019: 3 · 2017: 1 · 2016: 1 · 2015: 2 · 2014: 1 · 2013: 2 · 2012: 7
- FWCI
- 2.88
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Respiratory and Critical Care Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Keywords
- obstructive sleep apnea, continuous positive airway pressure, apnea-hypopnea index, snoring detection, quality of life, Epworth Sleepiness Scale, CPAP titration
- MeSH terms
- Female, Home Care Services, Humans, Male, Middle Aged, Sleep Apnea Syndromes, Single-Blind Method, Treatment Outcome, Cross-Over Studies, Continuous Positive Airway Pressure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.