CoChat

Randomized Study of Adding Inhaled Iloprost to Existing Bosentan in Pulmonary Arterial Hypertension

McLaughlin, Vallerie V., Oudiz, Ronald J., Frost, Adaani, Tapson, Victor F., Murali, Srinivas, Channick, Richard N., Badesch, David B., Barst, Robyn J., Hsu, Henry H., Rubin, Lewis J. · 2006 · American Journal of Respiratory and Critical Care Medicine
Cited by 626

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

RATIONALE: Small, open-label studies suggest that combinations of existing therapies may be effective for pulmonary arterial hypertension (PAH). OBJECTIVE: To evaluate the safety and efficacy of adding inhaled iloprost, a prostacyclin analog, to the endothelin receptor antagonist bosentan in patients with PAH. METHODS: In a randomized, multicenter, double-blind trial, inhaled iloprost (5 mug) or placebo was added to stable monotherapy with bosentan for 12 wk. Efficacy endpoints included change from baseline in 6-min-walk distance (6-MWD), modified New York Heart Association (NYHA) functional class, hemodynamic parameters, and time to clinical worsening. MEASUREMENTS AND MAIN RESULTS: A total of 67 patients with PAH (55% idiopathic PAH, 45% associated PAH, 94% NYHA class III, and mean baseline 6-MWD of 335 m) were randomized. At Week 12, patients receiving iloprost had a mean increase in 6-MWD of 30 m (p = 0.001); placebo patients had a mean 6-MWD increase of 4 m (p = 0.69), with a placebo-adjusted difference of +26 m (p = 0.051). NYHA status improved by one class in 34% of iloprost versus 6% of placebo patients (p = 0.002). Iloprost delayed the time to clinical worsening (p = 0.0219). Improvements were noted in postinhalation placebo-adjusted change in mean pulmonary artery pressure (-8 mm Hg; p < 0.001) and pulmonary vascular resistance (-254 dyn x s x cm(-5); p < 0.001). Combination therapy was well tolerated. CONCLUSIONS: Within the limitations of a relatively small sample size, results of this study demonstrate that the addition of inhaled iloprost in patients with PAH with reduced exercise capacity on bosentan monotherapy is safe and efficacious.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.200603-358oc

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 626

Metadata

Authors
McLaughlin, V. V., Oudiz, R. J., Frost, A., Tapson, V. F., Murali, S., Channick, R. N., Badesch, D. B., Barst, R. J., Hsu, H. H., & Rubin, L. J.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2006-12-01
Volume
174
Issue
11
Pages
1257-1263
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2023103539
Cited by
626
References
21
FWCI
40.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.