The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Examination of the Carbon Monoxide Diffusing Capacity (D l CO ) in Relation to Its K co and V a Components
Abstract
The single-breath carbon monoxide diffusing capacity (DL(CO)) is the product of two measurements during breath holding at full inflation: (1) the rate constant for carbon monoxide uptake from alveolar gas (kco [minute(-1)]) and (2) the "accessible" alveolar volume (Va). kco expressed per mm Hg alveolar dry gas pressure (Pb*) as kco/Pb*, and then multiplied by Va, equals Dl(CO); thus, Dl(CO) divided by Va (DL(CO)/Va, also called Kco) is only kco/Pb* in different units, remaining, essentially, a rate constant. The notion that DL(CO)/Va "corrects" DL(CO) for reduced Va is physiologically incorrect, because DL(CO)/Va is not constant as Va changes; thus, the term Kco reflects the physiology more appropriately. Crucially, the same DL(CO) may occur with various combinations of Kco and Va, each suggesting different pathologies. Decreased Kco occurs in alveolar-capillary damage, microvascular pathology, or anemia. Increased Kco occurs with (1) failure to expand normal lungs to predicted full inflation (extrapulmonary restriction); or (2) increased capillary volume and flow, either globally (left-to-right intracardiac shunting) or from flow and volume diversion from lost or damaged units to surviving normal units (e.g., pneumonectomy). Decreased Va occurs in (1) reduced alveolar expansion, (2) alveolar damage or loss, or (3) maldistribution of inspired gases with airflow obstruction. Kco will be greater than 120% predicted in case 1, 100-120% in case 2, and 40-120% in case 3, depending on pathology. Kco and Va values should be available to clinicians, as fundamental to understanding the clinical implications of DL(CO). The diffusing capacity for nitric oxide (DL(NO)), and the DL(NO)/DL(CO) ratio, provide additional insights.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interpretative strategies for lung function tests
Pellegrino, R., Viegi, G., Brusasco, V., Crapo, R. O., Burgos, F., Casaburi, R., Coates, A., van der Grinten, C. P. M., Gustafsson, P., Hankinson, J., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00035205 · Cited by 5,945
Standardisation of the single-breath determination of carbon monoxide uptake in the lung
MacIntyre, N., Crapo, R. O., Viegi, G., Johnson, D. C., van der Grinten, C. P. M., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Enright, P., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00034905 · Cited by 2,255
Ogilvie, C. M., Forster, R. E., Blakemore, W. S., & Morton, J. W. (1957) · Journal of Clinical Investigation · doi:10.1172/jci103402 · Cited by 1,201
Roughton, F. J. W., & Forster, R. E. (1957) · Journal of Applied Physiology · doi:10.1152/jappl.1957.11.2.290 · Cited by 999
Hepatopulmonary Syndrome — A Liver-Induced Lung Vascular Disorder
Rodríguez-Roisin, R., & Krowka, M. J. (2008) · New England Journal of Medicine · doi:10.1056/nejmra0707185 · Cited by 687
Standardization of the measurement of transfer factor (diffusing capacity)
Cotes, J. E., Chinn, D. J., Quanjer, P. H., Roca, J., & Yernault, J.-C. (1993) · European Respiratory Journal · doi:10.1183/09041950.041s1693 · Cited by 680
Steen, V., & Medsger, T. A. (2003) · Arthritis & Rheumatism · doi:10.1002/art.10775 · Cited by 494
The diffusion of gases through the lungs of man
Krogh, M. (1915) · The Journal of Physiology · doi:10.1113/jphysiol.1915.sp001710 · Cited by 432
Measurements of capillary dimensions and blood volume in rapidly frozen lungs.
Glazier, J. B., Hughes, J. M., Maloney, J. E., & West, J. B. (1969) · Journal of Applied Physiology · doi:10.1152/jappl.1969.26.1.65 · Cited by 249
Self-citationPuri, S., Baker, B. L., Dutka, D. P., Oakley, C. M., Hughes, J. M. B., & Cleland, J. G. F. (1995) · Circulation · doi:10.1161/01.cir.91.11.2769 · Cited by 248
Self-citation
Cited by
ERS/ATS technical standard on interpretive strategies for routine lung function tests
Stanojevic, S., Kaminsky, D. A., Miller, M. R., Thompson, B., Aliverti, A., Barjaktarevic, I., Cooper, B. G., Culver, B., Derom, E., Hall, G. L., et al. (2022) · European Respiratory Journal · doi:10.1183/13993003.01499-2021 · Cited by 1,656
2017 ERS/ATS standards for single-breath carbon monoxide uptake in the lung
Graham, B. L., Brusasco, V., Burgos, F., Cooper, B. G., Jensen, R., Kendrick, A., MacIntyre, N. R., Thompson, B. R., & Wanger, J. (2017) · European Respiratory Journal · doi:10.1183/13993003.00016-2016 · Cited by 972
Stanojevic, S., Graham, B. L., Cooper, B. G., Thompson, B. R., Carter, K. W., Francis, R. W., & Hall, G. L. (2017) · European Respiratory Journal · doi:10.1183/13993003.00010-2017 · Cited by 676
Metadata
- Authors
- Hughes, J. M. B., & Pride, N. B.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-07-15
- Volume
- 186
- Issue
- 2
- Pages
- 132-139
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2153769722
- Cited by
- 259
- References
- 42
- FWCI
- 11.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Examination of the Carbon Monoxide Diffusing Capacity (D l CO ) in Relation to Its K co and V a Components. https://app.cochat.ai/papers/10.1164/rccm.201112-2160ci
- The paper
- Hughes, J. M. B., & Pride, N. B. (2012). Examination of the Carbon Monoxide Diffusing Capacity (D l CO ) in Relation to Its K co and V a Components. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.201112-2160ci
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.