CoChat

Physiologic Effects of an Ambulatory Ventilation System in Chronic Obstructive Pulmonary Disease

Porszasz, Janos, Cao, Robert, Morishige, Richard, van Eykern, Leo A., Stenzler, Alex, Casaburi, Richard · 2013 · American Journal of Respiratory and Critical Care Medicine
Cited by 43

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

RATIONALE: Exercise intolerance limits the ability of patients with chronic obstructive pulmonary disease (COPD) to perform daily living activities. Noninvasive ventilation reduces dyspnea and improves exercise performance, but current systems are unsuitable for ambulatory use. OBJECTIVES: In patients with COPD experiencing exercise-induced desaturation, we evaluated improvements in exercise tolerance facilitated by a wearable, 1-lb, noninvasive open ventilation (NIOV) system featuring a nasal pillow interface during constant work rate (CWR) cycle ergometer exercise and associated effects on dyspnea, respiratory muscle activation, and pulmonary gas exchange efficiency. METHODS: Fifteen men with COPD (FEV₁ = 32.2 ± 12.0% predicted; FEV₁/FVC = 31.6 ± 7.1%; exercise oxygen saturation as measured by pulse oximetry [Spo₂] = 86.5 ± 2.9%) participated. After incremental testing establishing peak work rate, subjects completed three visits in which they performed CWR exercise to tolerance at 80% peak work rate: (1) unencumbered breathing room air, (2) using NIOV+compressed air, (3) using NIOV+compressed O₂, or (4) using O₂ via nasal cannula. Assessments included exercise duration, surface inspiratory muscle EMG, Spo₂, transcutaneous Pco₂, and Borg dyspnea scores. MEASUREMENTS AND MAIN RESULTS: Exercise endurance was 17.6 ± 5.7 minutes using NIOV+O₂, greatly prolonged compared with unencumbered (5.6 ± 1.9 min), nasal O₂ (11.4 ± 6.8 min), and NIOV+Air (6.3 ± 4.1 min). Isotime Spo₂ was higher and intercostal, scalene, and diaphragmatic EMG activity was reduced using NIOV+O₂ compared with unencumbered, nasal O₂, and NIOV+Air, signifying respiratory muscle unloading. Isotime dyspnea reduction correlated with isotime EMG reduction (r = 0.42, P = 0.0053). There were no significant differences in isotime VD/VT or transcutaneous Pco₂ among treatments. CONCLUSIONS: NIOV+O₂ yielded substantial exercise endurance improvements accompanied by respiratory muscle unloading and dyspnea reductions in patients with severe hypoxemic COPD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.201210-1773oc

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

Metadata

Authors
Porszasz, J., Cao, R., Morishige, R., van Eykern, L. A., Stenzler, A., & Casaburi, R.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2013-08-01
Volume
188
Issue
3
Pages
334-342
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2106860874
Cited by
43
References
22
FWCI
4.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.