In-Home Air Pollution Is Linked to Respiratory Morbidity in Former Smokers with Chronic Obstructive Pulmonary Disease
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
RATIONALE: The effect of indoor air pollutants on respiratory morbidity among patients with chronic obstructive pulmonary disease (COPD) in developed countries is uncertain. OBJECTIVES: The first longitudinal study to investigate the independent effects of indoor particulate matter (PM) and nitrogen dioxide (NO(2)) concentrations on COPD morbidity in a periurban community. METHODS: Former smokers with COPD were recruited and indoor air was monitored over a 1-week period in the participant's bedroom and main living area at baseline, 3 months, and 6 months. At each visit, participants completed spirometry and questionnaires assessing respiratory symptoms. Exacerbations were assessed by questionnaires administered at clinic visits and monthly telephone calls. MEASUREMENTS AND MAIN RESULTS: Participants (n = 84) had moderate or severe COPD with a mean FEV1 of 48.6% predicted. The mean (± SD) indoor PM(2.5) and NO(2) concentrations were 11.4 ± 13.3 µg/m(3) and 10.8 ± 10.6 ppb in the bedroom, and 12.2 ± 12.2 µg/m(3) and 12.2 ± 11.8 ppb in the main living area. Increases in PM(2.5) concentrations in the main living area were associated with increases in respiratory symptoms, rescue medication use, and risk of severe COPD exacerbations. Increases in NO(2) concentrations in the main living area were independently associated with worse dyspnea. Increases in bedroom NO(2) concentrations were associated with increases in nocturnal symptoms and risk of severe COPD exacerbations. CONCLUSIONS: Indoor pollutant exposure, including PM(2.5) and NO(2), was associated with increased respiratory symptoms and risk of COPD exacerbation. Future investigations should include intervention studies that optimize indoor air quality as a novel therapeutic approach to improving COPD health outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Miller, M. R., Hankinson, J., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Crapo, R., Enright, P., van der Grinten, C. P. M., Gustafsson, P., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00034805 · Cited by 15,627
KLEPEIS, N. E., NELSON, W. C., OTT, W. R., ROBINSON, J. P., TSANG, A. M., SWITZER, P., BEHAR, J. V., HERN, S. C., & ENGELMANN, W. H. (2001) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500165 · Cited by 4,803 · cited 1×
“In the United States, indoor air quality is important because Americans spend most of their time indoors (8), and individuals with COPD spend more time at home than their age-matched counterparts: approximately 82% of their time is spent indoors in their own home (9).”
BackgroundBestall, J. C., Paul, E. A., Garrod, R., Garnham, R., Jones, P. W., & Wedzicha, J. A. (1999) · Thorax · doi:10.1136/thx.54.7.581 · Cited by 2,927
Lepeule, J., Laden, F., Dockery, D., & Schwartz, J. (2012) · Environmental Health Perspectives · doi:10.1289/ehp.1104660 · Cited by 983
Breath Carbon Monoxide as an Indication of Smoking Habit
Middleton, E. T., & Morice, A. H. (2000) · Chest · doi:10.1378/chest.117.3.758 · Cited by 414 · cited 1×
“Inclusion criteria included (1) age greater than or equal to 40 years; (2) post-bronchodilator FEV1 less than or equal to 80% predicted; (3) FEV1/FVC less than 70%; and (4) more than 10 pack-years smoking, but having quit more than 1 year before enrollment and exhaled carbon monoxide level less than or equal to 6 ppm…”
Background
Cited by
Towards the elimination of chronic obstructive pulmonary disease: a Lancet Commission
Stolz, D., Mkorombindo, T., Schumann, D. M., Agusti, A., Ash, S. Y., Bafadhel, M., Bai, C., Chalmers, J. D., Criner, G. J., Dharmage, S. C., et al. (2022) · The Lancet · doi:10.1016/s0140-6736(22)01273-9 · Cited by 681
Self-citationIndoor Exposure to Selected Air Pollutants in the Home Environment: A Systematic Review
Vardoulakis, S., Giagloglou, E., Steinle, S., Davis, A., Sleeuwenhoek, A., Galea, K. S., Dixon, K., & Crawford, J. O. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17238972 · Cited by 545
The Effects of Air Pollution and Temperature on COPD
Hansel, N. N., McCormack, M. C., & Kim, V. (2016) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.3109/15412555.2015.1089846 · Cited by 283
Self-citationIndoor Air Pollution and Respiratory Health
Raju, S., Siddharthan, T., & McCormack, M. C. (2020) · Clinics in Chest Medicine · doi:10.1016/j.ccm.2020.08.014 · Cited by 217
Self-citationLevy, J. I., Quirós-Alcalá, L., Fabian, M. P., Basra, K., & Hansel, N. N. (2018) · Current Epidemiology Reports · doi:10.1007/s40471-018-0149-9 · Cited by 31
Self-citation
Metadata
- Authors
- Hansel, N. N., McCormack, M. C., Belli, A. J., Matsui, E. C., Peng, R. D., Aloe, C., Paulin, L., Williams, D. L., Diette, G. B., & Breysse, P. N.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-05-15
- Volume
- 187
- Issue
- 10
- Pages
- 1085-1090
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2171606444
- Cited by
- 127
- References
- 5
- FWCI
- 7.55
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In-Home Air Pollution Is Linked to Respiratory Morbidity in Former Smokers with Chronic Obstructive Pulmonary Disease. https://app.cochat.ai/papers/10.1164/rccm.201211-1987oc
- The paper
- Hansel, N. N., McCormack, M. C., Belli, A. J., Matsui, E. C., Peng, R. D., Aloe, C., Paulin, L., Williams, D. L., Diette, G. B., & Breysse, P. N. (2013). In-Home Air Pollution Is Linked to Respiratory Morbidity in Former Smokers with Chronic Obstructive Pulmonary Disease. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.201211-1987oc
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.