Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 308

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

Comparison of Echocardiographic Indices Used to Predict Fluid Responsiveness in Ventilated Patients

Vignon, Philippe, Repessé, Xavier, Bégot, Emmanuelle, Léger, Julie, Jacob, Christophe, Bouferrache, Koceila, Slama, Michel, Prat, Gwenaël, Vieillard-Baron, Antoine·2017·American Journal of Respiratory and Critical Care Medicine

Abstract

RATIONALE: Assessment of fluid responsiveness relies on dynamic echocardiographic parameters that have not yet been compared in large cohorts. OBJECTIVES: To determine the diagnostic accuracy of dynamic parameters used to predict fluid responsiveness in ventilated patients with a circulatory failure of any cause. METHODS: In this multicenter prospective study, respiratory variations of superior vena cava diameter (∆SVC) measured using transesophageal echocardiography, of inferior vena cava diameter (∆IVC) measured using transthoracic echocardiography, of the maximal Doppler velocity in left ventricular outflow tract (∆VmaxAo) measured using either approach, and pulse pressure variations (∆PP) were recorded with the patient in the semirecumbent position. In each patient, a passive leg raise was performed and an increase of aortic velocity time integral greater than or equal to 10% defined fluid responsiveness. MEASUREMENTS AND MAIN RESULTS: Among 540 patients (379 men; age, 65 ± 13 yr; Simplified Acute Physiological Score II, 59 ± 18; Sequential Organ Failure Assessment, 10 ± 3), 229 exhibited fluid responsiveness (42%). ∆PP, ∆VmaxAo, ∆SVC, and ∆IVC could be measured in 78.5%, 78.0%, 99.6%, and 78.1% of cases, respectively. ∆SVC greater than or equal to 21%, ∆VmaxAo greater than or equal to 10%, and ∆IVC greater than or equal to 8% had a sensitivity of 61% (95% confidence interval, 57-66%), 79% (75-83%), and 55% (50-59%), respectively, and a specificity of 84% (81-87%), 64% (59-69%), and 70% (66-75%), respectively. The area under the receiver operating characteristic curve of ∆SVC was significantly greater than that of ∆IVC (P = 0.02) and ∆PP (P = 0.01). CONCLUSIONS: ∆VmaxAo had the best sensitivity and ∆SVC the best specificity in predicting fluid responsiveness. ∆SVC had a greater diagnostic accuracy than ∆IVC and ∆PP, but its measurement requires transesophageal echocardiography.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.201604-0844oc

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 36 references

Cited by

See all 308

Metadata

Authors
Vignon, P., Repessé, X., Bégot, E., Léger, J., Jacob, C., Bouferrache, K., Slama, M., Prat, G., & Vieillard-Baron, A.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2017-04-15
Volume
195
Issue
8
Pages
1022-1032
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2521084084
Cited by
308
References
36
FWCI
24.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Echocardiographic Indices Used to Predict Fluid Responsiveness in Ventilated Patients. https://app.cochat.ai/papers/10.1164/rccm.201604-0844oc
The paper
Vignon, P., Repessé, X., Bégot, E., Léger, J., Jacob, C., Bouferrache, K., Slama, M., Prat, G., & Vieillard-Baron, A. (2017). Comparison of Echocardiographic Indices Used to Predict Fluid Responsiveness in Ventilated Patients. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.201604-0844oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.