Comparison of Echocardiographic Indices Used to Predict Fluid Responsiveness in Ventilated Patients
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
RATIONALE: Assessment of fluid responsiveness relies on dynamic echocardiographic parameters that have not yet been compared in large cohorts. OBJECTIVES: To determine the diagnostic accuracy of dynamic parameters used to predict fluid responsiveness in ventilated patients with a circulatory failure of any cause. METHODS: In this multicenter prospective study, respiratory variations of superior vena cava diameter (∆SVC) measured using transesophageal echocardiography, of inferior vena cava diameter (∆IVC) measured using transthoracic echocardiography, of the maximal Doppler velocity in left ventricular outflow tract (∆VmaxAo) measured using either approach, and pulse pressure variations (∆PP) were recorded with the patient in the semirecumbent position. In each patient, a passive leg raise was performed and an increase of aortic velocity time integral greater than or equal to 10% defined fluid responsiveness. MEASUREMENTS AND MAIN RESULTS: Among 540 patients (379 men; age, 65 ± 13 yr; Simplified Acute Physiological Score II, 59 ± 18; Sequential Organ Failure Assessment, 10 ± 3), 229 exhibited fluid responsiveness (42%). ∆PP, ∆VmaxAo, ∆SVC, and ∆IVC could be measured in 78.5%, 78.0%, 99.6%, and 78.1% of cases, respectively. ∆SVC greater than or equal to 21%, ∆VmaxAo greater than or equal to 10%, and ∆IVC greater than or equal to 8% had a sensitivity of 61% (95% confidence interval, 57-66%), 79% (75-83%), and 55% (50-59%), respectively, and a specificity of 84% (81-87%), 64% (59-69%), and 70% (66-75%), respectively. The area under the receiver operating characteristic curve of ∆SVC was significantly greater than that of ∆IVC (P = 0.02) and ∆PP (P = 0.01). CONCLUSIONS: ∆VmaxAo had the best sensitivity and ∆SVC the best specificity in predicting fluid responsiveness. ∆SVC had a greater diagnostic accuracy than ∆IVC and ∆PP, but its measurement requires transesophageal echocardiography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
Lang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.10.003 · Cited by 12,362
Acute Respiratory Distress Syndrome: The Berlin Definition
(2012) · JAMA · doi:10.1001/jama.2012.5669 · Cited by 8,731
The Surviving Sepsis Campaign Guidelines Committee including The Pediatric Subgroup*, Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., et al. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2769-8 · Cited by 7,290
Comparison of Two Fluid-Management Strategies in Acute Lung Injury
(2006) · New England Journal of Medicine · doi:10.1056/nejmoa062200 · Cited by 3,538
Cecconi, M., De Backer, D., Antonelli, M., Beale, R., Bakker, J., Hofer, C., Jaeschke, R., Mebazaa, A., Pinsky, M. R., Teboul, J. L., et al. (2014) · Intensive Care Medicine · doi:10.1007/s00134-014-3525-z · Cited by 1,767
Boyd, J. H., Forbes, J., Nakada, T.-A., Walley, K. R., & Russell, J. A. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181feeb15 · Cited by 1,517 · cited 1×
“5) Other causes 50 (9) 34 (11) 16 (7) Respiratory parameters Tidal volume, ml/kg 7.”
MICHARD, F., BOUSSAT, S., CHEMLA, D., ANGUEL, N., MERCAT, A., LECARPENTIER, Y., RICHARD, C., PINSKY, M. R., & TEBOUL, J.-L. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9903035 · Cited by 1,458
Vincent, J.-L., & De Backer, D. (2013) · New England Journal of Medicine · doi:10.1056/nejmra1208943 · Cited by 1,425
Cited by
Prediction of fluid responsiveness: an update
Monnet, X., Marik, P. E., & Teboul, J.-L. (2016) · Annals of Intensive Care · doi:10.1186/s13613-016-0216-7 · Cited by 600
A decade of progress in critical care echocardiography: a narrative review
Vieillard-Baron, A., Millington, S. J., Sanfilippo, F., Chew, M., Diaz-Gomez, J., McLean, A., Pinsky, M. R., Pulido, J., Mayo, P., & Fletcher, N. (2019) · Intensive Care Medicine · doi:10.1007/s00134-019-05604-2 · Cited by 270
Self-citationGeri, G., Vignon, P., Aubry, A., Fedou, A.-L., Charron, C., Silva, S., Repessé, X., & Vieillard-Baron, A. (2019) · Intensive Care Medicine · doi:10.1007/s00134-019-05596-z · Cited by 258
Self-citationPrediction of fluid responsiveness. What’s new?
Monnet, X., Shi, R., & Teboul, J.-L. (2022) · Annals of Intensive Care · doi:10.1186/s13613-022-01022-8 · Cited by 249
“A large study confirmed that changes in diameter, especially of the inferior vena cava, have low diagnostic sensitivity and specificity in detecting preload responsiveness, as assessed by the PLR test [72].”
BackgroundMethodInfluentialEgi, M., Ogura, H., Yatabe, T., Atagi, K., Inoue, S., Iba, T., Kakihana, Y., Kawasaki, T., Kushimoto, S., Kuroda, Y., et al. (2021) · Journal of Intensive Care · doi:10.1186/s40560-021-00555-7 · Cited by 224
How can assessing hemodynamics help to assess volume status?
De Backer, D., Aissaoui, N., Cecconi, M., Chew, M. S., Denault, A., Hajjar, L., Hernandez, G., Messina, A., Myatra, S. N., Ostermann, M., et al. (2022) · Intensive Care Medicine · doi:10.1007/s00134-022-06808-9 · Cited by 199
“Initially described in mechanically ventilated patients [63], the IVC variations were also applied in spontaneously breathing patients but performance was worse, and cutoffs higher than traditionally assumed had to be used [64, 65].”
BackgroundMethodSelf-citationBataille, B., de Selle, J., Moussot, P.-E., Marty, P., Silva, S., & Cocquet, P. (2021) · British Journal of Anaesthesia · doi:10.1016/j.bja.2020.11.039 · Cited by 56
Metadata
- Authors
- Vignon, P., Repessé, X., Bégot, E., Léger, J., Jacob, C., Bouferrache, K., Slama, M., Prat, G., & Vieillard-Baron, A.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2017-04-15
- Volume
- 195
- Issue
- 8
- Pages
- 1022-1032
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2521084084
- Cited by
- 308
- References
- 36
- FWCI
- 24.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.