Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 249

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Prediction of fluid responsiveness. What’s new?

Open access
Monnet, Xavier, Shi, Rui, Teboul, Jean-Louis · 2022 · Annals of Intensive Care

Abstract

Although the administration of fluid is the first treatment considered in almost all cases of circulatory failure, this therapeutic option poses two essential problems: the increase in cardiac output induced by a bolus of fluid is inconstant, and the deleterious effects of fluid overload are now clearly demonstrated. This is why many tests and indices have been developed to detect preload dependence and predict fluid responsiveness. In this review, we take stock of the data published in the field over the past three years. Regarding the passive leg raising test, we detail the different stroke volume surrogates that have recently been described to measure its effects using minimally invasive and easily accessible methods. We review the limits of the test, especially in patients with intra-abdominal hypertension. Regarding the end-expiratory occlusion test, we also present recent investigations that have sought to measure its effects without an invasive measurement of cardiac output. Although the limits of interpretation of the respiratory variation of pulse pressure and of the diameter of the vena cava during mechanical ventilation are now well known, several recent studies have shown how changes in pulse pressure variation itself during other tests reflect simultaneous changes in cardiac output, allowing these tests to be carried out without its direct measurement. This is particularly the case during the tidal volume challenge, a relatively recent test whose reliability is increasingly well established. The mini-fluid challenge has the advantage of being easy to perform, but it requires direct measurement of cardiac output, like the classic fluid challenge. Initially described with echocardiography, recent studies have investigated other means of judging its effects. We highlight the problem of their precision, which is necessary to evidence small changes in cardiac output. Finally, we point out other tests that have appeared more recently, such as the Trendelenburg manoeuvre, a potentially interesting alternative for patients in the prone position.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s13613-022-01022-8

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 249

Metadata

Authors
Monnet, X., Shi, R., & Teboul, J.-L.
Venue
Annals of Intensive Care
Publisher
Elsevier BV
Published
2022-05-28
Volume
12
Issue
1
Pages
46-46
ISSN
2110-5820 (ISSN-L)
OpenAlex
W4281719596
Cited by
249
References
2
FWCI
44.51
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prediction of fluid responsiveness. What’s new? https://app.cochat.ai/papers/10.1186/s13613-022-01022-8
The paper
Monnet, X., Shi, R., & Teboul, J.-L. (2022). Prediction of fluid responsiveness. What’s new? Annals of Intensive Care. https://doi.org/10.1186/s13613-022-01022-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.