Volume-controlled Ventilation Does Not Prevent Injurious Inflation during Spontaneous Effort

Yoshida, Takeshi, Nakahashi, Susumu, Nakamura, Maria Aparecida Miyuki, Koyama, Yukiko, Roldan, Rollin, Torsani, Vinicius, De Santis, Roberta R., Gomes, Susimeire, Uchiyama, Akinori, Amato, Marcelo B. P., Kavanagh, Brian P., Fujino, Yuji · 2017 · American Journal of Respiratory and Critical Care Medicine

Abstract

RATIONALE: Spontaneous breathing during mechanical ventilation increases transpulmonary pressure and Vt, and worsens lung injury. Intuitively, controlling Vt and transpulmonary pressure might limit injury caused by added spontaneous effort. OBJECTIVES: To test the hypothesis that, during spontaneous effort in injured lungs, limitation of Vt and transpulmonary pressure by volume-controlled ventilation results in less injurious patterns of inflation. METHODS: Dynamic computed tomography was used to determine patterns of regional inflation in rabbits with injured lungs during volume-controlled or pressure-controlled ventilation. Transpulmonary pressure was estimated by using esophageal balloon manometry [Pl(es)] with and without spontaneous effort. Local dependent lung stress was estimated as the swing (inspiratory change) in transpulmonary pressure measured by intrapleural manometry in dependent lung and was compared with the swing in Pl(es). Electrical impedance tomography was performed to evaluate the inflation pattern in a larger animal (pig) and in a patient with acute respiratory distress syndrome. MEASUREMENTS AND MAIN RESULTS: Spontaneous breathing in injured lungs increased Pl(es) during pressure-controlled (but not volume-controlled) ventilation, but the pattern of dependent lung inflation was the same in both modes. In volume-controlled ventilation, spontaneous effort caused greater inflation and tidal recruitment of dorsal regions (greater than twofold) compared with during muscle paralysis, despite the same Vt and Pl(es). This was caused by higher local dependent lung stress (measured by intrapleural manometry). In injured lungs, esophageal manometry underestimated local dependent pleural pressure changes during spontaneous effort. CONCLUSIONS: Limitation of Vt and Pl(es) by volume-controlled ventilation could not eliminate harm caused by spontaneous breathing unless the level of spontaneous effort was lowered and local dependent lung stress was reduced.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.201610-1972oc

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 162

Metadata

Authors
Yoshida, T., Nakahashi, S., Nakamura, M. A. M., Koyama, Y., Roldan, R., Torsani, V., De Santis, R. R., Gomes, S., Uchiyama, A., Amato, M. B. P., Kavanagh, B. P., & Fujino, Y.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2017-09-01
Volume
196
Issue
5
Pages
590-601
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2588606491
Cited by
162
References
3
FWCI
14.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Volume-controlled Ventilation Does Not Prevent Injurious Inflation during Spontaneous Effort. https://app.cochat.ai/papers/10.1164/rccm.201610-1972oc
The paper
Yoshida, T., Nakahashi, S., Nakamura, M. A. M., Koyama, Y., Roldan, R., Torsani, V., De Santis, R. R., Gomes, S., Uchiyama, A., Amato, M. B. P., Kavanagh, B. P., & Fujino, Y. (2017). Volume-controlled Ventilation Does Not Prevent Injurious Inflation during Spontaneous Effort. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.201610-1972oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.