Esophageal Manometry and Regional Transpulmonary Pressure in Lung Injury
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
RATIONALE: Esophageal manometry is the clinically available method to estimate pleural pressure, thus enabling calculation of transpulmonary pressure (Pl). However, many concerns make it uncertain in which lung region esophageal manometry reflects local Pl. OBJECTIVES: To determine the accuracy of esophageal pressure (Pes) and in which regions esophageal manometry reflects pleural pressure (Ppl) and Pl; to assess whether lung stress in nondependent regions can be estimated at end-inspiration from Pl. METHODS: In lung-injured pigs (n = 6) and human cadavers (n = 3), Pes was measured across a range of positive end-expiratory pressure, together with directly measured Ppl in nondependent and dependent pleural regions. All measurements were obtained with minimal nonstressed volumes in the pleural sensors and esophageal balloons. Expiratory and inspiratory Pl was calculated by subtracting local Ppl or Pes from airway pressure; inspiratory Pl was also estimated by subtracting Ppl (calculated from chest wall and respiratory system elastance) from the airway plateau pressure. MEASUREMENTS AND MAIN RESULTS: In pigs and human cadavers, expiratory and inspiratory Pl using Pes closely reflected values in dependent to middle lung (adjacent to the esophagus). Inspiratory Pl estimated from elastance ratio reflected the directly measured nondependent values. CONCLUSIONS: These data support the use of esophageal manometry in acute respiratory distress syndrome. Assuming correct calibration, expiratory Pl derived from Pes reflects Pl in dependent to middle lung, where atelectasis usually predominates; inspiratory Pl estimated from elastance ratio may indicate the highest level of lung stress in nondependent "baby" lung, where it is vulnerable to ventilator-induced lung injury.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
Bellani, G., Laffey, J. G., Pham, T., Fan, E., Brochard, L., Esteban, A., Gattinoni, L., van Haren, F., Larsson, A., McAuley, D. F., et al. (2016) · JAMA · doi:10.1001/jama.2016.0291 · Cited by 5,766
Self-citationEffect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome.
Amato, M. B. P., Barbas, C. S. V., Medeiros, D. M., Magaldi, R. B., Schettino, G. P., Lorenzi-Filho, G., Kairalla, R. A., Deheinzelin, D., Munoz, C., Oliveira, R., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199802053380602 · Cited by 3,654 · cited 1×
“To protect this nondependent “baby” lung, the clinician targets and limits global parameters such as VT (5, 6) and plateau pressure (Pplat) (6).”
BackgroundSelf-citationDriving pressure and survival in the acute respiratory distress syndrome.
Amato, M. B. P., Meade, M. O., Slutsky, A. S., Brochard, L., Costa, E. L. V., Schoenfeld, D. A., Stewart, T. E., Briel, M., Talmor, D., Mercat, A., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmsa1410639 · Cited by 2,801 · cited 1×
““baby” lung like driving pressure does, which is considered as a major determinant of ventilator-induced lung injury (31).”
BackgroundSelf-citationMechanical ventilation guided by esophageal pressure in acute lung injury.
Talmor, D., Sarge, T., Malhotra, A., O'Donnell, C. R., Ritz, R., Lisbon, A., Novack, V., & Loring, S. H. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0708638 · Cited by 1,149 · cited 17×
“Am J Respir Crit Care Med Vol 197, Iss 8, pp 1018–1026, Apr 15, 2018 Copyright © 2018 by the American Thoracic Society Originally Published in Press as DOI: 10.1164/rccm.201709-1806OC on January 11, 2018 Internet address: www.atsjournals.org 1018 American Journal of Respiratory and Critical Care Medicine Volume 197 Nu…”
BackgroundMethodInfluentialA simple method for assessing the validity of the esophageal balloon technique.
Baydur, A., BEHRAKIS, P. K., Zin, W. A., Jaeger, M., & Milic‐Emili, J. (1982) · PubMed · doi:10.1164/arrd.1982.126.5.788 · Cited by 1,076
Tidal Hyperinflation during Low Tidal Volume Ventilation in Acute Respiratory Distress Syndrome
Terragni, P. P., Rosboch, G., Tealdi, A., Corno, E., Menaldo, E., Davini, O., Gandini, G., Herrmann, P., Mascia, L., Quintel, M., et al. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200607-915oc · Cited by 820
The Application of Esophageal Pressure Measurement in Patients with Respiratory Failure
Akoumianaki, E., Maggiore, S. M., Valenza, F., Bellani, G., Jubran, A., Loring, S. H., Pelosi, P., Talmor, D., Grasso, S., Chiumello, D., et al. (2014) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201312-2193ci · Cited by 635
Self-citationEsophageal and transpulmonary pressure in the clinical setting: meaning, usefulness and perspectives
Mauri, T., Yoshida, T., Bellani, G., Goligher, E. C., Carteaux, G., Rittayamai, N., Mojoli, F., Chiumello, D., Piquilloud, L., Grasso, S., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4400-x · Cited by 554
Self-citationRecruitment and Derecruitment During Acute Respiratory Failure: An Experimental Study
PELOSI, P., GOLDNER, M., McKIBBEN, A., ADAMS, A., ECCHER, G., CAIRONI, P., LOSAPPIO, S., GATTINONI, L., & MARINI, J. J. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.1.2007010 · Cited by 524
Cited by
Marini, J. J., Rocco, P. R. M., & Gattinoni, L. (2020) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201908-1545ci · Cited by 297
Grieco, D. L., Menga, L. S., Eleuteri, D., & Antonelli, M. (2019) · Minerva Anestesiologica · doi:10.23736/s0375-9393.19.13418-9 · Cited by 249
Self-citationBertoni, M., Spadaro, S., & Goligher, E. C. (2020) · Critical Care · doi:10.1186/s13054-020-2777-y · Cited by 164
Positive-end expiratory pressure titration and transpulmonary pressure: the EPVENT 2 trial
Turbil, E., Galerneau, L. M., Terzi, N., Schwebel, C., Argaud, L., & Guérin, C. (2019) · Journal of Thoracic Disease · doi:10.21037/jtd.2019.06.34 · Cited by 8
Metadata
- Authors
- Yoshida, T., Amato, M. B. P., Grieco, D. L., Chen, L., Lima, C. A. S., Roldan, R., Morais, C. C. A., Gomes, S., Costa, E. L. V., Cardoso, P. F. G., Charbonney, E., Richard, J.-C. M., Brochard, L., & Kavanagh, B. P.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2018-04-15
- Volume
- 197
- Issue
- 8
- Pages
- 1018-1026
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2784003249
- Cited by
- 258
- References
- 26
- FWCI
- 21.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.