CoChat

Exhaled Nitric Oxide as a Diagnostic Test for Asthma: Online versus Offline Techniques and Effect of Flow Rate

Deykin, Aaron, Massaro, Anthony F., Drazen, Jeffrey M., Israel, Elliot · 2002 · American Journal of Respiratory and Critical Care Medicine
Cited by 152

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Measurement of the fraction of exhaled nitric oxide (FENO) has been proposed as a noninvasive assessment of asthmatic airway inflammation. The influence of the expiratory flow rate during the collection maneuver on the ability of FENO to discriminate healthy subjects from those with asthma is unknown. We compared online and offline measurement of FENO at different flow rates. FENO was collected with expiratory flows of 50-500 ml/second in 34 patients with asthma (PC(20) of less than 8 mg/ml) and 28 healthy subjects (PC(20) of more than 10 mg/ml) using offline collection techniques. In a subgroup of 18 individuals with asthma and 17 healthy subjects, we additionally measured FENO at multiple expiratory flow rates (47-250 ml/second) using online methods. FENO fell with an increasing expiratory flow rate; FENO was higher in subjects with asthma as compared with healthy subjects at each flow rate studied with both techniques (p < 0.001). Receiver operating characteristic (ROC) curves for the diagnosis of asthma indicated that FENO is a robust discriminator between individuals with asthma and healthy subjects (area under the ROC curves 0.79 +/- 0.06 to 0.86 +/- 0.06, p for significant discrimination < 0.0001). Neither expiratory flow rate nor collection technique (online versus offline) significantly altered this discriminatory capacity (area under the ROC curves = 0.84 +/- 0.07 with the slowest online method versus 0.80 +/- 0.07 with the fastest offline method, p = 0.46). These data indicate that the choice of expiratory flow rate and collection method can be based on practicality and patient comfort without compromising the utility of this test for asthma.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.2201081

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 152

Metadata

Authors
Deykin, A., Massaro, A. F., Drazen, J. M., & Israel, E.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2002-06-15
Volume
165
Issue
12
Pages
1597-1601
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2109813654
Cited by
152
References
1
FWCI
6.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.